Skip to main content

RoboDiag Harness 🩺🤖

A command-line tool for checking your robot's health and investigating problems.

License: Apache 2.0 ROS 2 Python

RoboDiag Harness terminal

Your robot is connected—but is it working properly? Is sensor data arriving? Are there any reported faults? What should you check when something goes wrong?

RoboDiag brings robot checks, telemetry, and diagnostic tools into one terminal interface.

Think of it as a robot checkup: collect evidence, inspect problems, and decide what to investigate next.

What can I use it for?

  • Check your robot — inspect its status and available diagnostic information.
  • Inspect sensor readings — view telemetry and collect samples over time.
  • Investigate problems — examine reported faults and review previous results.
  • Run supported tests — use the checks and actions available for your robot.
  • Give an AI assistant access to diagnostic tools — let it work with robot data through the harness.

Available features depend on the robot, its software, and the selected configuration.

Who is it for?

Robot owners, students, and developers who want a more convenient way to inspect and troubleshoot their robots.

You will need basic familiarity with a terminal. For the ROS 2 version, you also need a working ROS 2 environment.

You do not need an AI assistant to use the command-line interface.

What does “Harness” mean?

A harness connects tools together so they can be used through a common interface.

Here, it connects robot data, diagnostic checks, and supported actions—so you can access them from one place.

Getting started with ROS 2

1. Prepare your robot

For most robots, the simplest setup is to run RoboDiag on the robot's own computer, next to the robot's ROS 2 software:

  • ROS 2 is installed on that computer.
  • Your robot's ROS 2 software is running.
  • RoboDiag can reach the robot's topics, services and actions over the local ROS graph.

You can also run RoboDiag on a separate computer (ROS 2 is distributed, so nodes may live on different machines). In that case, additionally make sure that:

  • Both machines are on the same network and DDS discovery traffic is not blocked by a firewall.
  • ROS_DOMAIN_ID matches on both machines.
  • The ROS 2 distribution and message packages match — if the robot uses custom messages, source its workspace overlay (with ROBODIAG_WS, see step 3).

The launcher looks for ROS 2 under /opt/ros on the local machine. It uses the distribution identified by ROS_DISTRO when available, otherwise it tries Humble. RoboDiag does not use the robot's ROS installation remotely — the machine it runs on must have ROS 2 installed.

2. Download the project

git clone https://github.com/YueBit/robodiag-harness.git
cd robodiag-harness

3. Start RoboDiag

bash ./robodiag

If your robot needs a workspace overlay, specify its location:

ROBODIAG_WS=~/robot_ws bash ./robodiag

The workspace should already be built, with an install/setup.bash file.

4. Start with a check

Begin with status checks and telemetry inspection. Review the available data before acting on a conclusion.

Missing data does not necessarily mean broken hardware: the relevant sensor, driver, or ROS 2 node may not be running.

Configure your robot's interfaces

Robots may use different topic and service names. You can pass these to the launcher:

bash ./robodiag \
  --cmd-vel-topic /cmd_vel \
  --estop-service /emergency_stop

Use the names provided by your robot's software. Specifying a name does not create the corresponding topic or service.

Using it with an AI assistant

An AI assistant can use diagnostic tools to collect information and help interpret it.

A typical workflow is:

  1. You describe the problem.
  2. The assistant requests relevant robot data.
  3. It reviews the results and suggests further checks.
  4. You decide whether to act on its suggestions.

AI suggestions can be wrong. Check the underlying readings before acting on a conclusion.

Limitations

RoboDiag helps gather and interpret diagnostic evidence. It cannot guarantee that a robot is safe or identify every hardware fault.

The checks it can perform depend on the information and control interfaces your robot exposes. Support for ROS 2 does not mean every ROS 2 robot works without configuration.


Features

  • Inspect the ROS graph: nodes, topics, services and their types.
  • Collect standard /diagnostics (diagnostic_msgs/DiagnosticArray).
  • Inspect ros2_control through controller_manager services, when available.
  • Snapshot/sample any discovered ROS 2 topic by loading its message type at runtime; nothing is hard-coded.
  • Time-window sampling with min/max/mean/std/range statistics for jitter, drift, dropouts and intermittency.
  • Deterministic health tests (PASS / WARN / FAIL / SKIP) persisted to SQLite.
  • A fail-closed Safety Gate for motion-related operations.
  • A software emergency stop (zero Twist + optional Trigger service).
  • An OpenAI-compatible diagnostic agent (DeepSeek by default) with function calling.
  • A Jev (System One) next-tool router: Jev decides which read-only evidence tool to run next, then the LLM writes the final diagnosis.
  • rich terminal UI with an animated banner and /-command completion.

How it works

      natural language                         slash commands
            │                                        │
            ▼                                        ▼
   ┌────────────────────────────┐          ┌──────────────────┐
   │  Jev request router        │          │   REPL (rich)    │
   │  QUERY / DIAGNOSIS /       │          │  direct dispatch │
   │  ACTION / CHAT             │          └────────┬─────────┘
   └──────┬──────────┬──────────┘                   │
     QUERY│  DIAGNOSIS  │ACTION                     │
     concise│  Jev next-  │deterministic            │
     answer │  tool loop  │policy/safety            │
            │      │      │                         │
            │      ▼      │        same deterministic tools
            │  ┌─────────────────┐                    │
            │  │ LLM explainer   │                    │
            │  │ symptom +       │                    │
            │  │ evidence →      │                    │
            │  │ diagnosis       │                    │
            │  └────────┬────────┘                    │
            │           │                             │
            ▼           ▼                             ▼
   ┌──────────────────────────────────────────────────────────┐
   │                 Deterministic tool layer                 │
   │   HarnessNode (rclpy)  ·  TestRunner  ·  HistoryStore     │
   └───────────┬───────────────────────┬──────────────────────┘
               │                       │
       ROS 2 graph / topics       SQLite test history
               │
       ┌───────┴────────┐
       │  Safety Gate   │  fail-closed, no model in the loop
       │  diagnostics / │  checks freshness + battery + joints
       │  battery /     │
       │  joint states  │
       └────────────────┘

When TYPESAFE_API_KEY is not set, the classic LLM function-calling loop is used instead of the Jev routing. The division of labour with Jev enabled:

  • Jev request router classifies the task (System 1 — QUERY/DIAGNOSIS/ACTION/CHAT).
  • Jev diagnostic router decides what to investigate (System 1, inside DIAGNOSIS).
  • Deterministic tools decide what is true (measured evidence only).
  • The LLM explains what it means (System 2 — written diagnosis).
  • The Safety Gate decides what is allowed (fail-closed, deterministic code).

The core safety rule is unchanged:

The LLM may request evidence and tests, but deterministic code decides whether a write or motion operation is permitted.

How is this different from ros2 doctor?

ros2 doctor inspects the local ROS installation and its configuration. RoboDiag Harness inspects the live running graph and robot telemetry, samples topics over time, runs deterministic health tests, stores history, and adds an LLM agent that can decide which evidence to collect next.

Project structure

The harness is split into three top-level Python modules plus a launcher, so the safety-critical and decision-making pieces stay testable without a running robot.

File What it contains ROS needed?
robodiag_ros2.py Main CLI: the rclpy HarnessNode, the rich REPL, the LLM explainer, and the wiring that connects the tools, the Jev routers and the Safety Gate. Yes
robodiag_core.py Deterministic core (standard library only): JSON/statistics helpers, the SQLite HistoryStore, the read-only TEST_CATALOG and TestRunner, the fail-closed SafetyGate, and the ACTION capability registry. No
robodiag_jev.py Jev (System One) decision layer (standard library only): the RequestRouter, the DiagnosticState model, the TypeSafe API client, and the JevRouter that picks the next evidence tool. No
robodiag Bash launcher that sources ROS 2 and your robot workspace, then starts the Python harness. —

robodiag_core.py and robodiag_jev.py import only the Python standard library, so the deterministic safety logic and the routing decisions can be unit-tested in plain CI without ROS 2, rich, or network access.

Install with pip

pip install provides the robodiag console command. rclpy and the ROS message packages are not on PyPI — they come from your ROS 2 distribution, so source ROS before running.

# from PyPI (once published)
pip install robodiag-harness             # core (rich only)
pip install "robodiag-harness[all]"      # + prompt_toolkit completion + openai agent

# from source / editable
pip install -e ".[all]"

ROS 2 Humble images ship setuptools < 61 and may have no PyPI access. In that case build with the system setuptools instead of an isolated one:

pip install --user --no-build-isolation ".[all]"

Dependencies

  • ROS 2 (tested on Humble; mostly distro-agnostic), Python 3.10
  • rich (required)
  • prompt_toolkit (optional, live completion)
  • openai (optional, AI agent)
  • ros-humble-controller-manager-msgs (optional, for ros2_control checks)

REPL commands

RoboDiag REPL commands

/graph                         ROS graph summary
/diagnostics                   Standard /diagnostics status
/control                       ros2_control status
/check                         Composite read-only health check
/topic <topic>                 Snapshot one message from a topic
/sample <topic> [sec] [Hz]     Sample a topic over time and compute statistics
/tests                         Test catalog
/run <test_id>                 Run a deterministic test (all read-only in v0.2)
/history [n]                   Recent n test runs
/safety                        Show the motion Safety Gate
/stop                          Software stop: zero cmd_vel + optional Trigger service
/help /quit

Any other input is classified by the Jev request router into QUERY, DIAGNOSIS, ACTION or CHAT (requires TYPESAFE_API_KEY; DIAGNOSIS also requires DEEPSEEK_API_KEY for the final explanation).

CLI flags

Flag Default Purpose
--controller-manager /controller_manager controller_manager node namespace
--cmd-vel-topic /cmd_vel topic used by the software stop
--estop-service (none) optional std_srvs/Trigger E-stop service
--db ~/.robodiag_ros2.db SQLite history path
--model deepseek-chat LLM model; overrides DEEPSEEK_MODEL
--base-url https://api.deepseek.com OpenAI-compatible base URL
--api-key (none) LLM API key (visible in ps/shell history)
--api-key-file (none) read the API key from a file (safer)
--jev-api-key (none) TypeSafe API key (visible in ps/shell history)
--jev-api-key-file (none) read the TypeSafe API key from a file (safer)
--jev-base-url https://api.typesafe.ai TypeSafe base URL
--jev-model jev-latest Jev model; overrides TYPESAFE_MODEL

AI diagnostic agent

The agent runs a function-calling loop of at most 10 rounds. Each tool result is fed back as structured JSON, and the final answer follows a fixed shape: symptom → evidence → assessment → possible causes → recommended next checks.

Tools and risk layers

Layer Tool What it does
Read-only inspect_graph Nodes, topics, services and types
Read-only get_diagnostics Cached standard /diagnostics statuses
Read-only inspect_ros2_control Controllers, hardware components, interfaces
Read-only get_topic_snapshot One message from any discovered topic
Read-only sample_topic Time-window sampling with statistics
Read-only list_tests Deterministic test catalog
Read-only run_test Run one deterministic health test
Read-only query_history Recent test runs from SQLite
Read-only check_motion_safety Run the deterministic Safety Gate
Emergency emergency_stop Software stop: zero Twist + optional Trigger service. Never blocked.

v0.2 contains no write or motion tool, so there is nothing to confirm. When motion extensions land, the Safety Gate and an explicit operator confirmation will gate them. See Motion extensions (future) for the plan.

Configuration

The agent resolves its LLM settings with this precedence:

CLI flags  >  environment variables  >  ~/.robodiag.env  >  built-in defaults

~/.robodiag.env:

DEEPSEEK_API_KEY=sk-...
DEEPSEEK_BASE_URL=https://api.deepseek.com
DEEPSEEK_MODEL=deepseek-chat

TYPESAFE_API_KEY=apikey_...
TYPESAFE_BASE_URL=https://api.typesafe.ai
TYPESAFE_MODEL=jev-latest

One-off overrides, including non-DeepSeek providers (any OpenAI-compatible endpoint):

./robodiag --model deepseek-reasoner
./robodiag --base-url https://dashscope.aliyuncs.com/compatible-mode/v1 --model qwen-max
./robodiag --api-key-file ~/.deepseek.key      # safer than --api-key

--api-key works but is visible in ps and shell history. Prefer DEEPSEEK_API_KEY in ~/.robodiag.env (mode 600) or --api-key-file.

Jev uses the same precedence: --jev-* flags > TYPESAFE_* environment variables > ~/.robodiag.env > built-in defaults.

Jev System One routing

With TYPESAFE_API_KEY set, Jev — TypeSafe's System One model — has two separate routing roles:

  1. Request routing — first classify the operator's input into one of QUERY, DIAGNOSIS, ACTION or CHAT (and, for QUERY/ACTION, resolve the specific capability/action).
  2. Diagnostic routing — if (and only if) the input is a DIAGNOSIS, decide which evidence/tool to collect next.
user input → Jev request router
               ├─ QUERY     → one deterministic lookup → concise answer
               ├─ DIAGNOSIS → Jev diagnostic loop → LLM explanation
               ├─ ACTION    → deterministic read-only test / software stop
               └─ CHAT      → lightweight reply (no tools)

Simple questions such as "what is the battery level?" are answered directly (Battery: 73% (15.6 V)) without entering the diagnostic loop.

RoboDiag replies in the same language as the operator. The language is detected from the script of the input (e.g. 现在电量多少? → Chinese); when the language is unclear (for example Latin-script text), replies default to English.

Diagnostic routing

Inside a DIAGNOSIS, Jev acts as a fast next-tool router:

  1. Jev receives the symptom and the evidence collected so far.
  2. Jev picks the next read-only diagnostic action (a Choice over the tool set).
  3. The deterministic tool runs and its result is appended to the evidence.
  4. When Jev picks finalize, the LLM (System 2) writes the final diagnosis: symptom → evidence → assessment → possible causes → recommended next checks.
symptom → Jev: get_diagnostics → Jev: run_test(joint_states_health)
        → Jev: sample_topic(/joint_states) → Jev: finalize → LLM report

Jev returns calibrated probabilities for every choice; the router follows the highest-probability action and prints the top three with confidence. Jev may propose the next tool and finalize, but deterministic gates decide what is allowed:

  • Finalize gate — finalize is withheld until at least one tool call has returned successful evidence (MIN_EVIDENCE_ITEMS).
  • Exact repeat guard — the same (tool, canonical arguments) call cannot repeat; the same tool with different arguments (e.g. sampling two topics) is still allowed.
  • Per-tool budget — each tool is capped at 3 calls per diagnosis.
  • Total bound — at most 8 tool calls per diagnosis.
  • Topic shortlist — topics are deterministically ranked (name tokens, message type, symptom keywords, prior evidence) down to ≤ 24, and Jev is always offered none_of_the_above so it is never forced to pick a bad topic.

Jev is only allowed to route read-only evidence tools. emergency_stop and any future motion/write tool are never in Jev's action set — they stay behind the deterministic Safety Gate and the /stop command.

The routing layer consumes a single DiagnosticState (symptom, tool_calls, test_results, evidence, graph_summary, step) and returns a decision, so Jev can later be swapped for an LLM-, rule-, or replay-based router without the harness below changing.

Jev (System 1) LLM (System 2)
Role Decide what to investigate next Explain what the evidence means
Output Typed choice + calibrated probabilities Free-form written diagnosis
Speed ~70–500 ms, parallel, no generation Seconds, autoregressive
Failure mode Cannot hallucinate a tool call Never executes tools; only writes

With only DEEPSEEK_API_KEY (no Jev), the classic LLM function-calling agent is used as the fallback. The /jev command shows which router is active.

Health thresholds

Variable Default Meaning
ROBODIAG_MIN_BATTERY_PCT 0.10 minimum battery percentage for motion
ROBODIAG_MIN_BATTERY_V 0.0 minimum battery voltage for motion
ROBODIAG_MAX_DIAG_AGE_S 5.0 max age of /diagnostics before it is stale
ROBODIAG_MAX_BATTERY_AGE_S 5.0 max age of battery state before it is stale
ROBODIAG_MAX_JOINT_STATE_AGE_S 1.0 max age of /joint_states before it is stale
ROBODIAG_DB ~/.robodiag_ros2.db SQLite history path

Test catalog

test_id Checks Outcomes
graph_health Node/topic counts; presence of /joint_states FAIL if only the harness node is visible; WARN if /joint_states is missing
diagnostics_health /diagnostics freshness and levels SKIP if none received; FAIL on stale or ERROR/STALE; WARN on WARN
joint_states_health Samples /joint_states: rate, finite values, named joints WARN on low rate / few samples / missing positions
ros2_control_health controller_manager controllers, hardware, interfaces SKIP if unavailable; FAIL if hardware is not active
system_health Composite of the four tests above Worst sub-result

Every run is written to SQLite and can be inspected with /history or the query_history tool.

Design principles

  1. Evidence before reasoning. The agent must gather real telemetry; it may not invent hardware state from the robot model.
  2. Deterministic code decides writes. The Safety Gate is plain code, is fail-closed, and distinguishes unhealthy evidence from missing evidence. "No data" is never treated as "normal".
  3. Structured results. Evidence and tests are first-class objects (Evidence, TestResult), not free-form strings.
  4. Narrow decisions, composed in code. Jev (System 1) only answers "which tool next?" with calibrated probabilities; the LLM (System 2) only writes the explanation. Neither model may choose an emergency stop or a motion/write action.

Testing

The test suite is split into offline and live parts. The offline parts run without ROS 2, rich, or any API key — they import only robodiag_core and robodiag_jev.

python3 -m unittest test_core            # deterministic core (fully offline)
python3 test_jev.py                      # Jev next-tool router (offline + live)
python3 test_request_router.py           # request router (offline + live)
  • test_core.py — unit tests for the deterministic core: JSON/statistics helpers, the SQLite history store, test-result semantics, the Safety Gate, and the routing whitelists. Runs fully offline and also works with pytest test_core.py.
  • test_jev.py — smoke test for the Jev next-tool router. It always runs offline wiring checks; live TypeSafe API checks run only when TYPESAFE_API_KEY is available (environment variable or ~/.robodiag.env) and are skipped otherwise.
  • test_request_router.py — smoke test for the QUERY / DIAGNOSIS / ACTION / CHAT request router and language detection. Offline wiring checks always run; live classification runs only when TYPESAFE_API_KEY is available.

Motion extensions (future)

v0.2 provides read-only diagnostic tests and a software stop command. It does not initiate motion.

Future versions may add motion tests and other write actions. When they land:

  • The Safety Gate and an explicit operator confirmation will gate them.
  • Place the robot in a clear, stable area and keep people and obstacles away from moving parts before any movement test.
  • Know how to stop your robot independently of RoboDiag.
  • Review the requested action before confirming it.

A software stop command depends on the robot's implementation and communication connection. It does not replace a physical emergency stop.

Contributing

Bug reports, documentation improvements, and robot integrations are welcome.

When reporting an issue, please include:

  • Your robot model and ROS 2 distribution.
  • The command or check you ran.
  • What you expected and what happened.
  • Relevant logs, with credentials and private information removed.

The v0.2 test catalog is intentionally read-only; new tests should follow the same rule — deterministic, structured evidence, and no motion without a Safety Gate precondition.

License

Apache License 2.0 — see LICENSE.

ROS and ROS 2 are trademarks of Open Robotics. This project is not affiliated with or endorsed by Open Robotics or Intrinsic.

Metadata

Release files for robodiag-harness 0.2.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for robodiag-harness 0.2.0
File Size Uploaded
robodiag_harness-0.2.0.tar.gz 62.1 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for robodiag-harness 0.2.0
File Interpreter ABI Platform
robodiag_harness-0.2.0-py3-none-any.whl Python 3 none any Details

Total release size: 116.2 kB

Release files / robodiag_harness-0.2.0.tar.gz

Download URL robodiag_harness-0.2.0.tar.gz
Size 62.1 kB
Tags Source
SHA-256 checksum
How to use checksums
808311c3b3bbd9f0ca16f7e23ac4ef5577f3663452275eb6a358acb22a07a814
BLAKE2b-256 checksum
How to use checksums
ef3ec4a4c73cdeaeafcec5875a458dc4bbc9da9658609051f52ebc4809d2bdd4
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.13.14

Release files / robodiag_harness-0.2.0-py3-none-any.whl

Download URL robodiag_harness-0.2.0-py3-none-any.whl
Size 54.1 kB
Tags Python 3
SHA-256 checksum
How to use checksums
2830d00a01f3299b3eae015d387eff822a85b704181641e163a8f179099dfb5d
BLAKE2b-256 checksum
How to use checksums
9a520ce51db6ea93cd3222b857cea92da06b3dca7febc32ca94fc0b53927ccdf
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.13.14

Release history Release notifications | RSS feed

This release

0.2.0 This release

2 release files

0.1.2

2 release files

0.1.1

2 release files

0.1

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page