This release is a pre-release and may not be stable for production use.
RotorVibe
Composable rotating-machine vibration analysis for Python.
RotorVibe turns calibrated waveform blocks into spectra, bearing-frequency markers, condition-relative evidence and inspectable diagnostic candidates. Use the NumPy API inside your own application; the local web dashboard is optional.
Alpha research release, version 0.1.0a5. Signal calculations and bounded software checks are documented. Fault classifiers have not qualified for unattended field diagnosis: new-bearing and independent-rig transfer tests failed. No remaining-life prediction, automatic shutdown authority or standards certification is supplied.
한국어 설명 · User guide · Algorithm notes · Development record · Continue this research · Source/rights policy
Install
Python 3.11+ with NumPy 2.x and SciPy 1.13+ is required.
Install the explicit alpha version (Python 3.11+):
python -m pip install rotorvibe==0.1.0a5
The 0.1.0a5 release integrates P0–P2. GitHub release, PyPI and Zenodo version DOI identify this release. The earlier 0.1.0a1 files remain historical, immutable artifacts.
For an editable checkout and verification tools:
git clone https://github.com/lyullee/rotorvibe.git
cd rotorvibe
python -m pip install -e ".[verification]"
python -m unittest discover -s tests -v
The public facade is rotorvibe; the earlier vibration namespace remains available
so existing Python integrations can keep their imports. Raw experimental data and
trained rig-specific profiles are acquired separately, not installed by pip.
P0–P2 release and verification
| Series | Main changes | Evidence |
|---|---|---|
| P0 | Strict profile/numeric/decision contracts; build from an explicit version tag | P0 report |
| P1 | Scoped normal fit/calibration, acquisition quality, angle models, holds, coverage/alarm metrics, lifecycle and bounded queue | P1 guide / P1 report |
| P2 | Result isolation, real optional bridge, common profiles, PSD history, reviewed rules and explicit life experiments | P2 guide / P2 report |
The release preparation passed 224 tests, seven documentation blocks in two clean environments, and 58 additional engineering checks using previously exposed reader fixtures. See combined release record for exact scope, reproduction commands and final publication-check locations. Release CI gates Windows/Linux Python 3.11–3.13, real optional-package checks and installed-wheel regressions before publishing. Counts from historical phases are not added together.
This is software verification. New measured fault accuracy and field remaining-life accuracy remain unqualified. A 48 kHz/four-channel burst case missed its 250 ms latency budget 17 times. The sealed P1 waveforms were not fitted or tested.
P2 composition APIs — 0.1.0a5
These are in-process Python APIs. No server or database is required. All times are seconds in the named caller clock; frequency axes are Hz. See P2 guide for full parameter contracts and verification for results.
| Module / API | Purpose | Required inputs | Outputs / mutation policy |
|---|---|---|---|
AnalysisResult.detached(); VibrationAnalyzer |
Isolate consumers | Existing result; configured stages/sinks | Independent nested payload/metadata/array copies. Each stage/sink receives a separate snapshot; object identity with the returned result is intentionally different |
process_adapter_info() |
Inspect optional bridge compatibility | Installed distribution metadata | Installed/supported version and compatibility; supported process-monitoring-toolkit==0.1.0 |
from_process_batch(batch, *, sample_rate_hz, clock_id, rpm=None) |
Process waveform into vibration | Actual supported SignalBatch, uniform time, common physical unit, one episode/mode, independent scalar or per-sample RPM |
SignalBlock; validity and metadata['vibration_source'] preserved. Reject gaps, mixed identities and feature rows |
to_process_batch(results) |
Vibration features into process pipeline | Ordered results with matching clock, measurement/source and feature schemas | SignalBatch[windows, 7*channels], dimensionless log/ratio features at exclusive window end; invalid rows masked, raw RMS reference unit retained in metadata |
condition_evidence(result, *, asset_id) |
Neutral condition observation | Result and explicit asset ID | Detached evidence mapping; no accident probability |
create_profile(...), validate_profile(...), profile_digest(value) |
Common inert model envelope | Payload, ID/kind, algorithm, feature schema, preprocessing, original training groups, calibration history and scope | Finite JSON envelope, SHA-256s and compatibility checks; no model conversion or authenticity guarantee |
ProfileRegistry.register/get/load/remove/list |
Explicit profile selection | Envelope; on get/load exact expected contract and scope; on load algorithm-specific callable | Detached envelope or native loaded model. Duplicate IDs rejected; native loader still validates numerical contents |
SpectrogramAccumulator(hop_seconds=..., ...) |
Bounded time-frequency history | AnalysisResult rows; max_frames, max_age_seconds, max_frequencies |
update summary and detached snapshot with Hz/bin edges, start/end times, validity, segment IDs and gaps; missing windows are not fabricated |
SpectrogramStage(accumulator) |
Connect history to analyzer | Accumulator with matching hop | Small update summary; reset clears history. Full history remains in accumulator |
vibration.iso.RuleDocument, RuleProvider, MemoryRuleProvider |
Supply reviewed engineering rules | Caller-owned Rule, edition/source/hash, reviewer/date, exact reviewed context |
Scoped document or no match; ambiguity rejected. No standard tables included |
vibration.iso.evaluate_with_provider(...); IsoStage(..., rule_provider=...) |
Evaluate caller rules with provenance | Standard identifier, context, qualified measurement/provider; stage additionally checks live asset/condition/location/state/RPM | Per-location zone or indeterminate result, source/review hashes; never whole-machine certification |
vibration.experimental.ReferenceLifeEstimator |
Explicit reference-life experiment | Legacy accelerated-bench catalog and experimental_enabled=True; causally available prefix |
Experimental benchmark-end similarity only. Legacy models.LifeEstimator and LifeStage now default disabled |
vibration.experimental.LifeHistory, evaluate_life_predictions(...) |
Evaluate complete/censored life forecasts | Original group IDs, operating conditions, elapsed RMS history, event/censor follow-up, final forecasts and excluded training/calibration groups | Equal-life MAE/RMSE, empirical interval coverage and censored-survival compatibility; unavailable exact errors stay None |
The DSP heatmap now averages PSD within explicit frequency bins instead of
interpolating isolated grid points. Narrow tones remain visible and discrete PSD
power is preserved (apart from the declared display floor). The existing
spectrogram['frequencies'] and ['db'] fields remain; bin edges and representation
metadata are added. This display is not a lossless STFT or a model feature matrix.
import numpy as np
from rotorvibe import (AnalysisConfig, SignalBlock, VibrationAnalyzer,
SpectrogramAccumulator, SpectrogramStage)
fs = 12000
history = SpectrogramAccumulator(hop_seconds=0.25, max_frames=32, max_age_seconds=10)
seen = []
def consumer(result):
result.payload['metrics']['rms'] = -999 # isolated local edit
analyzer = VibrationAnalyzer(AnalysisConfig(unit='m/s^2'),
stages={'history': SpectrogramStage(history)}, sinks=(consumer, seen.append))
t = np.arange(2 * fs) / fs
rows = analyzer.push(SignalBlock(np.sin(2 * np.pi * 100 * t), fs,
unit='m/s^2', channels=('radial',), metadata={'asset_id': 'demo-motor'}))
assert len(rows) == 5 and len(history.snapshot()['rows']) == 5
assert rows[-1].metrics['rms'] > 0 and seen[-1] is not rows[-1]
Run python examples/p2_composition.py for a reviewed illustrative-rule chain.
For the optional actual package bridge, first install the inspected Git commit
(the version was unavailable from the queried package index), then the local extra:
python -m pip install "git+https://github.com/lyullee/process-monitoring-toolkit.git@79b4cf52a0acd0d0cbd3addbe82c3d98d6385e5a"
python -m pip install ".[process]"
python examples/process_bridge.py
That example runs SignalBatch -> SignalBlock -> AnalysisResult -> feature SignalBatch -> Monitor. Reused synthetic rows demonstrate wiring only. Production fit,
calibration and final acquisitions must remain independent. Real remaining-life
accuracy and statistical interval calibration are still unqualified.
P1 monitoring APIs — included in 0.1.0a5
P1 adds installation/RPM/load-scoped normal registration, recording-disjoint calibration, actionable holds, coverage-aware evaluation, measured-speed angle features, explicit lifecycle hooks and a bounded host-driven processing queue. These P1 APIs are included in 0.1.0a5; install the pinned version above or this source checkout.
| Unit / API | Inputs | Outputs / boundary |
|---|---|---|
AcquisitionInfo(...), AcquisitionQualityStage(required_band_hz=None, require_measured_rpm=False) |
Asset, sensor/installation/calibration IDs; measurement/due dates; channel order/axes; Hz, g or m/s^2, sensor band and anti-alias cutoff; RPM provenance; explicit calibration/mounting/anti-alias flags | accepted / hold / quality_hold, issues; checks host declarations, never certifies a sensor installation |
NormalRecording(record_id, group_id, observations, confirmed_normal, role='unassigned', sha256=None) |
Original acquisition group, valid analysis results, explicit normal_fit or normal_calibration role; optional actual raw checksum. from_plan(record, observations, confirmed_normal=...) binds a DatasetRecord. |
Reference-fitting input; final-test roles, repeated groups and supplied duplicate hashes rejected |
fit_normal_reference(fit_records, calibration_records, *, name, rpm_range, load_range, quantile=.99, representation='time', samples_per_revolution=256, revolutions=16) |
At least 2 original groups per role, reviewed acquisition evidence, explicit rev/min and load interval; source load_unit required | JSON-compatible reference; equal group-weighted median/MAD, calibration uses maximum score per recording; empirical limits, no field FPR guarantee |
NormalReferenceBank(profiles=()), ReferenceStage(bank, representation='time') |
Compatible registered profiles and results; matches asset, installation, calibration, frame, channel/axis order, filters, units, condition, RPM and load | normal / hold / anomaly_unknown + normal_score, thresholds, reference ID. Missing/overlapping/out-of-range references hold; no silent overwrite |
hold_guidance(output), GuidanceStage(source_stage='decision') |
Named producer's status/reason | required_actions with machine-readable codes and affected parameters; never relabels asset/scope automatically |
angle_resample(values, sample_rate_hz, rpm_trace, *, samples_per_revolution=256, revolutions=16) |
Calibrated N or N×C waveform and measured per-sample rev/min; bounded angular grid | Read-only angle array and speed/filter metadata; trapezoidal phase integration, conservative prefilter, rejects unresolved bandwidth |
angle_features(...) |
Same waveform/trace/settings | AngleFeatures(names, values, metadata); 23 features/channel: log RMS/crest/kurtosis and 0.5X..10X fractions; separate angle schema |
fit_angle_fault_discriminator(...), AngleFaultDiscriminator(profile), AngleFaultStage(model, gate_key='reference', experimental_enabled=False) |
New angle features/profiles, independent original groups, real channel/RPM provenance. Stage needs an earlier confirmed anomaly and qualified measured RPM | Experimental conditional fault candidates only; old fixed-speed profiles cannot be reused. Off by default; measured-data qualification pending |
ValidationObservation(...), evaluate_observations(rows, fault_onsets=None, max_gap_seconds=2) |
Original record/acquisition/asset/clock identities, interval seconds, ground truth, pipeline decision and alarm level; optional actual onset | Acceptance, decision coverage, supported-normal FPR, unconditional and conditional type metrics, separate known-fault head accuracy, acquisition counts, union exposure time, observed alarms/hour and delay. Zero supported denominator -> None |
DatasetRecord(...), ValidationPlan(records, independent_by='acquisition'), FrozenEvaluation(plan_path, plan_sha256=..., access_log=..., max_record_bytes=134217728) |
Actual record/group/session/installation/rig IDs, role, label, SHA256; explicit freeze of model/preprocessing hashes | Reject leakage, no-overwrite freeze, record access before decode; loader receives a verified BytesIO snapshot. Reopened tests require replay=True and remain exposed; not a sandbox for external host reads |
VibrationAnalyzer.reset(reset_stages=False, preserve_profiles=True) |
Explicit lifecycle policy | Legacy reset stays buffer-only. With reset_stages=True invokes optional reset_state hooks. Established push-stream gaps/identity changes reset state automatically; the first push does not cancel an explicitly started collection |
RealtimeProcessor(analyzer, max_pending=4, max_chunk_samples=None, max_pending_bytes=67108864, overflow='reject', latency_budget_seconds=None) |
Immutable chunk snapshots; explicit queue/byte/chunk limits and reject/drop_oldest policy; host calls process_next/drain | Completed result list, admission receipt and bounded timing stats (processing/queue/latency/deadline misses). One consumer, no implicit worker, no hard realtime guarantee |
P1 complete composition example
This synthetic example tests API wiring. The four generated records do not prove independent normal sessions, and its evidence flags must not be copied to field data.
import numpy as np
from rotorvibe import (AcquisitionInfo, AcquisitionQualityStage, AnalysisConfig,
SignalBlock, VibrationAnalyzer, NormalRecording, fit_normal_reference,
NormalReferenceBank, ReferenceStage, DecisionStage, GuidanceStage,
AlarmStage, RealtimeProcessor)
fs = 12000
config = AnalysisConfig(sample_rate_hz=fs, unit="g", window_seconds=2,
hop_seconds=2, load=0.5, rpm=1200)
# Synthetic test declarations only; measured data need actual reviewed evidence.
info = AcquisitionInfo("demo-rig", "sensor-1", "mount-1", "demo-calibration",
"2026-11-04", "2027-01-01", ("radial",), ("radial",), fs, "g",
(1, 6000), 5500, "controller_nominal",
calibrated=True, mounting_verified=True, anti_alias_verified=True)
def block(index, amplitude, installation="mount-1"):
source = {"asset_id": "demo-rig", "condition_id": "steady",
"load_unit": "fraction_rated", "acquisition": info.to_dict()}
source["acquisition"]["sensor_installation_id"] = installation
samples = amplitude * np.sin(2 * np.pi * 20 * np.arange(fs * 2) / fs)
return SignalBlock(samples, fs, unit="g", rpm=1200, start_time_s=index * 2,
channels=("radial",), metadata=source)
preprocessor = VibrationAnalyzer(config)
def recording(index, amplitude, role):
return NormalRecording(f"record-{index}", f"acquisition-{index}",
(preprocessor.analyze(block(index, amplitude)),), True, role)
profile = fit_normal_reference(
[recording(0, 1.00, "normal_fit"), recording(1, 1.04, "normal_fit")],
[recording(2, 1.01, "normal_calibration"),
recording(3, 1.03, "normal_calibration")],
name="demo-reference", rpm_range=(1188, 1212), load_range=(0.4, 0.6))
bank = NormalReferenceBank([profile])
analyzer = VibrationAnalyzer(config, stages={
"acquisition": AcquisitionQualityStage(),
"reference": ReferenceStage(bank),
"decision": DecisionStage("reference"),
"guidance": GuidanceStage("decision"),
"alarm": AlarmStage(score_stage="decision", expected_score_name="normal_score",
warning=profile["anomaly_limit"], danger=2 * profile["anomaly_limit"],
persistence_seconds=0, release_seconds=0),
})
processor = RealtimeProcessor(analyzer, max_pending=2, overflow="reject")
assert processor.submit(block(4, 1.02))["accepted"]
normal = processor.process_next()[0]
assert normal.payload["decision"]["status"] == "normal"
assert processor.submit(block(5, 1.02, installation="new-mount"))["accepted"]
held = processor.process_next()[0]
assert held.payload["decision"]["status"] == "hold"
assert held.payload["guidance"]["required_actions"]
assert held.payload["alarm"]["level"] == "unavailable"
print(normal.payload["decision"]["status"], held.payload["guidance"])
processor.close()
The time reference path requires <=3% within-window speed variation. The optional single-channel angle reference path uses representation='angle' and actual measured RPM; its grid and feature schema are stored in the new profile. The raw trace is available as result.rpm_trace / payload['_rpm_trace']; to_dict(include_features=False) omits it. Existing fixed-speed models still hold on unsupported variable speed.
Profile lifecycle belongs to the host. preserve_profiles=False clears an owned BaselineStage profile; a ReferenceStage detaches from its shared bank without deleting host profiles. Call stage.activate() to reattach; bank.clear() is an explicit host action. For direct analyze() windows the host still declares stream boundaries with reset; automatic continuity detection applies to push(). Custom stages opt in via reset_state(*, preserve_profiles=True).
Benchmarks include a real observed limit: queued 48 kHz/4-channel bursts exceeded a 0.25 s latency budget. Queue controls expose this; they do not make the condition pass. New external archives are sealed and have not trained or qualified these models. See P1 operating guide, verification and remaining qualification and new data receipt.
P0 fixes and common module I/O (0.1.0a2 candidate)
This checkout includes the P0 fixes introduced in the earlier 0.1.0a2 candidate. The archived/PyPI 0.1.0a1 distribution remains unchanged; use the pinned 0.1.0a5 distribution or its matching source tag for these APIs. No new measured-data accuracy or field qualification is claimed.
| API / module | Input changes | Output / compatibility |
|---|---|---|
FaultDiscriminator(profile) |
Load now validates required fields, nonempty asset_id/condition_id, calibrated acceleration unit g or m/s^2, finite JSON scope, unique nonempty feature names, selected mode/indices and original-acquisition groups. Multiple original groups per class and operational_use=False are required. | Valid existing fit-generated profiles remain supported. Malformed profiles formerly accepted now raise ValueError. Do not remove identity to bypass scope. |
fit_fault_discriminator(...) |
Uses the same scope/name contract as loading. Feature magnitudes <=1e100; model parameters finite and bounded. | Same algorithm identifier, features and normal-range calculation; verifies its returned profile through the loader. |
FaultDiscriminator.predict(features, rpm, *, scope) |
Missing/invalid caller scope -> hold. Nonfinite/out-of-range features or overflowing intermediate distance calculation -> ValueError. | Returns a finite decision or raises explicitly; never emits NaN/Infinity as a successful numeric result. |
normalize_decision(output, *, source_stage, valid=True) |
Stage mapping, explicit producer name, bool window validity. Recognizes score or normal_score; simultaneous scores must agree; no conversion of similarity weights to scores. | Common vibration.decision.v1 mapping described below; does not mutate producer output or calibrate thresholds. |
DecisionStage(source_stage) |
Add after the named producer and before alarm/other consumers. Missing producer -> explicit hold. | Adds the common mapping under the host-chosen stage name; legacy producer fields remain untouched. |
AlarmStage(..., expected_score_name=None) |
Optional expected source score definition (score or normal_score). Existing score_stage/threshold/time parameters retain their meaning. | Handles the common mapping. Holds/invalid/mismatched score kinds -> unavailable with retained_level, never implicit normal/recovery. Legacy score callbacks still work; stale scores attached to legacy holds are ignored. |
Common mapping fields:
| Field | Type / meaning |
|---|---|
| schema, source_stage | vibration.decision.v1 and named producer |
| status | normal / scored / candidate / anomaly_unknown / fault_candidate / hold / invalid |
| score, score_name, score_unit | Finite nonnegative float or None; source definition (score / normal_score) and dimensionless unit. No score is fabricated for fault-only heads. |
| label, anomaly | Optional label and bool/None anomaly evidence. A Gaussian known_candidate becomes candidate; it does not prove a physical anomaly. |
| alarm_eligible | True only with a supported non-held/non-invalid state and a numeric score. A held borderline score can remain visible but is never used for alarm updates. |
| reason, operational_use | Nonempty reason and False for this research decision contract |
Thresholds are not interchangeable: a baseline score and a conditioned normal_score have different calibration. Set warning/danger for the selected model and optionally enforce expected_score_name. The adapter does not infer new thresholds.
Executable baseline → common decision → alarm example
Synthetic repeated waves below demonstrate integration, not independent healthy acquisitions or a field-calibrated alarm. Zero persistence is for this short example.
import numpy as np
from rotorvibe import (AnalysisConfig, SignalBlock, VibrationAnalyzer,
BaselineStage, DecisionStage, AlarmStage)
fs = 12000
values = 0.2 * np.sin(2 * np.pi * 20 * np.arange(fs) / fs)
config = AnalysisConfig(sample_rate_hz=fs, unit="g", rpm=1200,
window_seconds=1, hop_seconds=1)
baseline = BaselineStage(config)
baseline.begin(name="synthetic-demo", windows=20)
analyzer = VibrationAnalyzer(config, stages={
"baseline": baseline,
"decision": DecisionStage("baseline"),
"alarm": AlarmStage(score_stage="decision", expected_score_name="score",
persistence_seconds=0, release_seconds=0),
})
for index in range(21):
result = analyzer.analyze(SignalBlock(
values, fs, unit="g", start_time_s=index, rpm=1200,
metadata={"asset_id": "demo-rig", "condition_id": "steady"},
))
assert result.payload["decision"]["status"] == "scored"
assert result.payload["alarm"]["level"] == "normal"
held = analyzer.analyze(SignalBlock(
values, fs, unit="g", start_time_s=21, rpm=1200,
metadata={"asset_id": "different-rig", "condition_id": "steady"},
))
assert held.payload["decision"]["status"] == "hold"
assert held.payload["alarm"]["level"] == "unavailable"
print(result.payload["decision"], held.payload["alarm"])
Release workflow contract
The initial archive-restoration workflow has been replaced. Release dispatch requires an existing version tag (e.g. v0.1.0a2), never main. The guard checks tag syntax, package/facade versions, HEAD/tag equality and a clean checkout. It performs no source restoration, commit, ref update or push. Build/tests/content audits and an installed wheel/example check precede publishing. PyPI and GitHub use the same build artifacts; SHA256SUMS accompanies the GitHub release. Publishing is triggered only by an explicit version-tag push or release dispatch, not an ordinary branch push.
The candidate has not been published merely by running local validation. See P0 validation and compatibility notes for actual checks.
Module map: purpose, inputs and outputs
Start here when integrating RotorVibe into another Python system. Each row is
an importable calculation or integration unit. A web server is not required for the
core. Names in rotorvibe.__all__ are available from rotorvibe; deeper utilities
use the vibration.* import paths shown below. N = samples, C = channels,
W = observations/windows, F = features; Hz = cycles/s and RPM = rev/min.
host DAQ -> SignalBlock + AnalysisConfig -> VibrationAnalyzer
-> DSP / bearing markers -> ordered stages -> AnalysisResult -> host sinks
baseline -> alarm
normal gate -> conditional fault-type head
caller-supplied measurement rule
Core calculations and replaceable interfaces
| Module / Python entry point | Purpose | Inputs / important parameters | Output / next connection |
|---|---|---|---|
contracts: SignalBlock |
Typed waveform input | values: float[N] or float[N,C], actual sample_rate_hz, unit, time/identity/validity fields below |
Read-only copied samples, normalized to [N,C]; input to analyze / push |
config: AnalysisConfig |
Analysis, calibration and band settings | Sample rate, channel count/index, window/hop seconds, units, sensitivity, RPM and filter bands | Validated configuration; create(dict), to_dict(), signature() |
core: VibrationAnalyzer(config=None, *, bearing_provider=None, stages=None, sinks=()) |
Synchronous calculation / stream windowing | Config, optional geometry provider, ordered {name: stage}, result callbacks |
analyze(block) -> AnalysisResult; push(block) -> list[AnalysisResult]; reset() -> None |
core.analyze_signal(values, config=None, **block_options) |
One-call complete-window calculation | Samples, config and SignalBlock options; exactly one configured window |
AnalysisResult; constructs a new analyzer (no retained stream) |
dsp: spectrum(x, fs, window='hann') |
One-sided FFT and PSD | 1-D samples, sample rate Hz, hann / hamming / boxcar |
(frequency_hz[K], amplitude[K], psd[K]); amplitude in input unit, PSD in unit²/Hz |
dsp.channel_features(data, fs) |
Shared numerical feature vector | Finite waveform [N,C], sample rate Hz |
(names, vector[F]), 7 features/channel: log RMS, log crest, Pearson kurtosis and 4 log band fractions |
dsp.analyze(data, config, rpm_trace=None, bearing_frequencies=None, *, native=False) |
Metrics, envelope, spectra and harmonic evidence | Physical waveform, validated config, optional RPM [N], marker {name: Hz} |
Payload dictionary described below; low-level API, use VibrationAnalyzer for calibration/quality/identity checks |
dsp.waveform(x, fs, maximum=1600, *, native=False) / compact_spectrum(f, a, maximum=1800, *, native=False) |
Prepare plot arrays | Waveform or frequency/value arrays; display size limit | {x, y}; native=True preserves full arrays, display compaction is not a measurement input |
dsp.peak_evidence(f, amplitude, target, tolerance_ratio, resolution, *, spacing_hz=None) |
Find local peak near a predicted frequency | Frequency/amplitude arrays, target and resolution Hz, relative tolerance, optional harmonic spacing | Evidence dictionary or None; unresolved bands explicitly reported |
geometry: BearingGeometry(rolling_elements, rolling_diameter, pitch_diameter, contact_angle_deg=0) |
Ideal bearing defect-frequency calculation | Count, diameters in the same length unit, angle degrees; .frequencies(rpm) |
{BPFI, BPFO, FTF, BSF, 2BSF} in Hz; no slip correction or vendor catalog |
geometry.BearingMap(geometries) |
Replaceable geometry lookup | {bearing_id: BearingGeometry}; .frequencies(id, rpm) |
Same frequency mapping; inject as bearing_provider and set config.bearing_id |
ports: BearingProvider, ResultStage, WindowStage, ResultSink |
Structural contracts for host-written modules | Provider .frequencies(id,rpm); stage __call__(result); optional .analyze_window(result, readonly_values); sink __call__(result) |
Provider -> Hz map; stage -> named payload; sink -> side effect, return ignored |
Normal references, alarms and experimental diagnostic units
Profiles are explicit dictionaries, not bundled trained models. Training arrays are
[W,F]; feature names/order must match at inference. groups[W] identifies original
acquisitions, not shuffled windows. scope records the actual asset/sensor/condition
contract used by that profile. Keep normal fitting, calibration and final test
acquisitions disjoint. These models are experimental, with operational_use=False.
| Module / Python entry point | Purpose | Inputs / important parameters | Output / next connection |
|---|---|---|---|
baseline: BaselineStage(config, *, profile=None) |
Collect or reuse a robust normal reference | Config; optional compatible profile; .begin(name='normal', windows=60) then valid results with source identity |
Stage dict: status, score when supported, contributions; .export_profile() -> dict or None |
alarm: AlarmStage(*, score_stage='baseline', warning=3, danger=6, persistence_seconds=2, release_seconds=3, max_gap_seconds=2) |
Observation-time alarm persistence | An earlier payload's score, result validity, clock/episode/end time; threshold ordering and durations |
{level, pending, score} or unavailable/retained level; no machine-trip authority |
rotor_features: extract_rotor_features(values, sample_rate_hz, rpm, *, channel_names=None) |
Speed-referenced harmonics, levels and cross-channel ratios | Waveform [N,C], finite positive RPM, actual sample rate and channel names |
RotorFeatures(names, values, sample_rate_hz, rpm, channel_names, sample_count, schema); .values is a feature vector |
classifier: fit_gaussian(x, y, groups, *, variance_floor=0.25, feature_schema=...) |
Fit standardized diagonal Gaussian baseline | Features [W,F], class labels [W], acquisition groups, variance floor and schema |
Profile dict; GaussianClassifier(profile).predict(vector) -> label/matches; not calibrated probabilities |
two_stage: fit_two_stage(...) / TwoStageDiagnostic(profile) |
Normal-first screening followed by known fault matching | Fit: normal_fit, normal_fit_groups, normal_calibration, calibration_groups, faults, fault_labels, fault_groups; keyword feature_names, scope, mode, quantiles, min_margin |
Profile; .predict(features, *, scope) or .analyze(values, sample_rate_hz, rpm, *, scope, channel_names=None) -> decision dict |
two_stage.TwoStageStage(model) |
Attach two-stage model to analyzer | Model and calibrated raw window + result metadata | Named diagnostic payload; rejects invalid / unsupported variable-speed inputs |
conditioned: fit_conditioned(...) / ConditionedDiagnostic(profile) |
RPM-conditioned normal-reference bank | Fit: normal, normal_rpm, normal_groups, calibration, calibration_rpm, calibration_groups, faults, fault_rpm, fault_labels, fault_groups; keyword feature_names, scope, mode, interpolation/gap/uncertainty/margin |
Profile; .predict(features, *, scope) or .analyze(values, sample_rate_hz, rpm, *, scope, channel_names=None) -> decision dict, hold outside supported scope |
conditioned.ConditionedStage(model) |
Attach conditioned gate to analyzer | Model and result/raw-window pair | Gate output containing decision status and anomaly evidence; use before fault head |
fault_discrimination: fault_features(values, sample_rate_hz, rpm) |
Morphology for separating looseness / imbalance / misalignment | Exactly 2 seconds of one channel, actual sample rate and RPM | (names, vector[61]); fixed-speed research feature contract |
fit_fault_discriminator(x, labels, rpms, groups, *, names, scope, mode='morphology', rpm_penalty=1, margin=0.03) |
Fit conditional fault-type prototypes | Fault-only feature matrix, labels, RPM per row, acquisition groups, names, scope, feature mode and rejection parameters | Profile dict; excludes a healthy class |
FaultDiscriminator(profile) |
Conditional fault-type inference | .predict(features, rpm, *, scope) or .analyze(values, sample_rate_hz, rpm, *, scope) |
{status, label, ...}: hold / anomaly_unknown / fault_candidate; requires prior anomaly screening |
FaultDiscriminationStage(model, gate_key='conditioned') |
Enforce gate-before-head composition | Earlier payload[gate_key]['anomaly'] is True, valid window and scope; RPM variation <=3% |
Fault-head dict; otherwise hold with explicit reason |
stages: ClassifierStage(registry) / LifeStage(estimator, experimental_enabled=False) |
Bridge host registry / reference-life estimator into stages | Injected registry or estimator and result/raw window | Classification / life payload; constructor does not start training |
models: ModelRegistry(storage, catalog) |
Optional stored models and explicit training jobs | Storage/catalog; load(name), use_two_stage(profile), use_conditioned(profile), train(name) |
Classification dict or training-job status; .close() releases worker resources |
models.LifeEstimator(catalog, experimental_enabled=False).estimate(source) |
Experimental PRONOSTIA reference-life similarity | Training complete-life catalog and observed-prefix metadata: dataset, record ID, RPM, baseline/recent RMS | Refusal state or experimental remaining_seconds, reference range and matches; not validated field RUL, reference range is not a confidence interval |
Engineering measurement and user-supplied criteria
The vibration.iso namespace has no distributed ISO/KS threshold tables or machine
selectors. Limits come from the caller. available_standards() returns ().
| Module / Python entry point | Purpose | Inputs / important parameters | Output / next connection |
|---|---|---|---|
iso.contracts: MachineContext |
Identify assessment condition | Required asset_id, machine; explicit operating_state, condition_id, location; optional engineering context |
Validated context; extra category fields do not enable built-in normative selectors |
iso.contracts.Measurement |
Typed magnitude at a measurement point | value, quantity, unit, statistic, frame, band_hz, duration_s, axis, point_id; calibration/acquisition flags and provenance |
Typed observation; .canonical_value() -> acceleration m/s², velocity mm/s, displacement µm |
iso.contracts.Rule |
Caller-owned limit contract | standard, key, quantity, statistic, frames, increasing limits, band_hz, source_page, source_clause; optional zones, duration, notes |
Validated rule; .to_dict() -> serializable contract; no implicit RMS/peak conversion |
iso.measurements: measure_waveform(values, *, ...) |
Measure filtered waveform magnitude | Required sample_rate_hz, input_unit, quantity, statistic, frame, band_hz, point_id, axes; calibration/acquisition flags, time/clock, optional order/filter bandwidth |
list[Measurement], one per channel; DFT band integration, no instrument certification |
energy_equivalent_average(measurements) / EnergyEquivalentAccumulator(period_s).push(measurement) |
Duration-weighted RMS averaging | Compatible RMS observations with matching units/point/band/time context; accumulation period seconds | Averaged Measurement; accumulator returns None until period reached |
iso.evaluation: evaluate(standard, context, measurement, *, custom_rule=None) |
Assess one observation against explicit limits | Rule ID, context, measurement, caller Rule |
Dict: status, zone, canonical value/unit and rule provenance; no rule / mismatch -> no zone; equality stays in lower interval |
iso.evaluation.aggregate(results) |
Preserve assessed-point coverage | Nonempty per-point results for same asset/rule/condition | Combined dict; whole_machine_compliance=False |
iso.stage: IsoStage(standard, context, *, custom_rule=None, rule_provider=None, point_id, axis='radial', calibrated=False, acquisition_verified=False) |
Raw waveform -> measurement -> rule in one stage | One-channel window and explicit context/rule/qualification flags | Named evaluation payload; no rule -> indeterminate; multi-channel input requires separate per-channel use |
Integration, acquisition, data access and optional service
| Module / Python entry point | Purpose | Inputs / important parameters | Output / ownership |
|---|---|---|---|
adapters: from_process_batch(batch, *, sample_rate_hz, clock_id, rpm=None) |
Convert host batch to waveform contract | Object with uniform time_s, values, common channel units, channels, origin, metadata; optional validity/episode/mode |
SignalBlock; split mixed modes/episodes first |
adapters.to_process_batch(results) |
Convert results into feature batch | Compatible AnalysisResult iterable; matching clock, measurement settings, feature order |
External process_monitoring.SignalBatch, [W,F], timestamps at exclusive window end; requires host-installed process_monitoring, not a pip dependency |
adapters.condition_evidence(result, *, asset_id) |
Neutral condition observation for other modules | Result and explicit asset identity | vibration.condition-evidence.v1 dict; not accident probability/frequency |
datasets: DatasetCatalog |
Optional local dataset index/import | Locally acquired files; search(...), details(id), load(id, snapshot=0); imported(filename, payload, fs=None, unit='unknown', channels_axis=1, skip_columns=0) |
Index metadata or (array, metadata); raw files are not installed or downloaded automatically |
independent_data: IndependentRotorCatalog |
Group-aware rotor acquisition reader | Explicit root/manifest; rows(*, role=None, normal_only=False), load(record_id, *, frozen_model_sha256=None) and Marra archive methods |
File identities / waveform blocks and metadata; preserve original-acquisition split |
condition_data: UosRotorCatalog / ExposedCrossSpeedDevelopment |
Conditioned-study readers | Local dataset root; rows(role=None) and load(record_id, *, frozen_model_sha256=None) for UOS |
Rows and (array, metadata); readers are not pretrained models or fresh holdouts |
client: VibrationClient(base_url='http://127.0.0.1:8765', token='', timeout=30) |
Optional HTTP/UDP producer | .start(sample_rate_hz, channels, unit, rpm, **configuration), .push(samples, **kwargs) / .push_udp(...), .stop() |
Server JSON / sent-packet response; server owns analysis, host owns network/retries |
engine: Engine(storage, catalog, bearings, models) |
Optional live/replay worker | Injected services; configure(values), live(...), ingest(payload), replay(id, speed, loop, ...) |
State/events/history; EventHub distributes events, Ring buffers samples; call .close() |
storage: Storage |
Optional local SQLite state | Sessions/config, result frames, events and named profiles via save/get/history |
IDs / stored rows / retrieved documents; writable runtime directory, .close() |
server: Application / rotorvibe-monitor |
Optional HTTP/SSE/UDP dashboard | CLI --host, --port; runtime/project environment paths and configured authentication |
Local service/UI and streamed observations; close application resources; no server in direct core |
bearings: Bearings / bootstrap |
Optional dashboard lookup / project-path bootstrap | Separately supplied local catalog files and project/runtime paths | Service lookup / environment paths; use BearingGeometry + BearingMap for portable host integration |
Exact input contract and configuration parameters
analyze requires N == round(sample_rate_hz * window_seconds);
push accepts arbitrary nonempty chunks and returns zero or more complete windows.
Config and block sample rate, channel count and input unit must agree. One analyzer
instance owns one stream; the host serializes calls and owns DAQ scheduling.
SignalBlock parameter |
Type / default | Meaning and unit |
|---|---|---|
values |
Required array [N] or [N,C] |
Numeric samples; copied and made read-only, 1..16 channels |
sample_rate_hz |
Required positive finite number | Actual sampling frequency Hz |
unit |
'unknown' |
g, m/s^2, V, or uncalibrated unknown; physical meaning must be declared |
start_time_s |
0.0 |
First sample time in caller clock, seconds |
clock_id, episode_id |
'sample_clock', 'default' |
Time-basis and continuous-acquisition identity; set deliberately |
channels |
() |
Ordered unique names; auto-generated if omitted |
valid |
None or bool [N] |
Sample-validity mask; nonfinite sample values are also invalid |
rpm |
None, scalar or [N] |
Externally measured rev/min; block value overrides config |
sequence |
None or nonnegative integer |
Consecutive acquisition packet identity |
metadata |
{} |
Actual asset/sensor/condition/calibration/frame provenance; propagated under result.metadata['source'] |
AnalysisConfig fields (defaults) |
Purpose / unit |
|---|---|
sample_rate_hz=12000, channels=1, channel=0 |
Hz; total channels and zero-based channel selected for scalar spectra/metrics; feature vector uses all channels |
window_seconds=1, hop_seconds=0.25 |
Window and step seconds; 256..2,000,000 samples/window; hop >=0.02 s and <= window |
unit='unknown', input_representation='physical' |
Output acceleration unit g / m/s^2 or unknown; representation physical / volts |
sensitivity_mv_per_g=None, conditioner_gain=1, bias_voltage_v=0, calibration_id='' |
Voltage -> g calibration: (V-bias)/(sensitivity/1000*gain); sensitivity list of 1 or C positive values; calibrated output unit required for voltage mode |
rpm=None, bearing_id=None, condition, load=None |
Nominal rev/min, host bearing lookup ID, operating-condition name and optional load metadata |
window='hann' |
FFT window; also hamming / boxcar |
envelope_low_hz=500, envelope_high_hz=5000 |
Carrier band Hz, strictly below Nyquist; configure lower bands for low-rate data |
velocity_low_hz=10, velocity_high_hz=1000 |
Acceleration integration band Hz; output mm/s RMS |
peak_tolerance_ratio=0.03 |
Relative marker peak-search tolerance, also bounded by frequency resolution |
warning_score=3, danger_score=6, persistence_seconds=2, release_seconds=3 |
Optional service policy settings; direct AlarmStage has its own explicit arguments and must be attached |
rms_warning=None, rms_danger=None, clip_abs=None |
Optional service RMS thresholds and absolute clipping level, in configured unit; clip check also used by direct core |
model_enabled=False, order_tracking=True |
Optional service classifier switch; RPM-trace angle resampling switch. Models are attached explicitly in direct API |
Output contract: what downstream code receives
AnalysisResult field / payload |
Meaning / unit |
|---|---|
start_time_s, end_time_s, clock_id, episode_id, channels |
Window identity; end time is exclusive; seconds in declared clock |
valid / payload['quality']['flags'] |
Numeric-window quality, not a healthy/fault label; invalid windows omit numeric DSP results |
metrics |
AC rms, peak, peak_to_peak, mean, rms_raw in configured unit; crest_factor, Pearson kurtosis, skewness dimensionless; velocity_rms_mm_s; envelope_rms; band_power in unit² |
payload['spectrum'], ['psd'], ['envelope_spectrum'] |
{x,y} arrays: x Hz; y amplitude, unit²/Hz, or envelope amplitude respectively |
payload['waveform'] |
{x,y} with relative seconds and calibrated samples for selected channel |
payload['spectrogram'] |
One window's frequency grid and log-PSD row (frequencies, db); host stacks rows over time to form a spectrogram |
payload['rpm'], ['rpm_variation_ratio'], ['frequency_resolution_hz'], ['order_spectrum'] |
Rev/min, dimensionless speed variation, Hz bin spacing; optional order axis (cycles/revolution) with resampling mode |
payload['bearing_markers'], ['rotation_markers'], ['diagnosis'] |
Predicted/observed Hz, peak contrast and nonexclusive candidate evidence; not confirmed faults |
features, feature_names |
Full feature vector and exact ordered names; keep together with configuration/profile schema |
payload[stage_name] |
Stage-defined output; baseline score, alarm level, diagnostic dict or custom-rule assessment |
metadata['measurement'], metadata['source'] |
Effective configuration and original host metadata |
to_dict(include_features=True) |
JSON-compatible vibration.analysis.v1 dictionary; False removes internal underscore-prefixed feature fields |
Stage order is insertion order. Later stages can read earlier named payloads.
Raw-window stages receive calibrated full arrays, not plot-decimated arrays.
Stage/sink exceptions propagate to the caller; sinks run synchronously after stages.
Use separate analyzer instances for different assets. A diagnostic hold or a missing
score must not be converted to normal or zero risk by the downstream system.
For every public constructor/method signature and dataclass field, see the complete source-derived API reference. The tables above are the integration map; the user guide explains operating sequences.
A complete first calculation
This generated waveform verifies the API; it is not a measured fault example.
import numpy as np
from rotorvibe import AnalysisConfig, SignalBlock, VibrationAnalyzer
fs = 12000
t = np.arange(fs) / fs
samples = 0.20 * np.sin(2 * np.pi * 20 * t)
analyzer = VibrationAnalyzer(AnalysisConfig(
sample_rate_hz=fs, channels=1, unit="m/s^2",
window_seconds=1, hop_seconds=0.25, rpm=1200,
))
result = analyzer.analyze(SignalBlock(
samples, fs, unit="m/s^2", rpm=1200,
channels=("drive_radial",), clock_id="daq_elapsed", episode_id="run-001",
metadata={"asset_id": "motor-01", "condition_id": "rated_load"},
))
print(result.valid, result.metrics)
serializable = result.to_dict(include_features=False)
samples may also be an N × C array. A one-dimensional input represents one
channel. Supply the physical unit, channel ordering, time basis and actual asset
identity; a numeric array alone cannot establish sensor calibration or installation.
Connect modules directly
The host controls acquisition, scheduling, storage and decisions. An analyzer instance owns one stream; application callbacks receive the results synchronously.
import numpy as np
from rotorvibe import AnalysisConfig, SignalBlock, VibrationAnalyzer
from rotorvibe import BearingGeometry, BearingMap
received = [] # Replace with your own event bus / storage callback.
class MyCalculation:
def __call__(self, result):
return {"quality_accepted": result.valid}
fs = 12000
samples = 0.20 * np.sin(2 * np.pi * 20 * np.arange(fs) / fs)
analyzer = VibrationAnalyzer(
AnalysisConfig(sample_rate_hz=fs, unit="m/s^2", rpm=1200,
bearing_id="demo", window_seconds=1),
bearing_provider=BearingMap({"demo": BearingGeometry(8, 7.0, 35.0)}),
stages={"host_calculation": MyCalculation()},
sinks=(received.append,),
)
result = analyzer.analyze(SignalBlock(
samples, fs, unit="m/s^2", rpm=1200, channels=("drive_radial",),
clock_id="daq_elapsed", episode_id="run-001",
metadata={"asset_id": "motor-01", "condition_id": "rated_load"},
))
assert received[0] is not result # Independent sink snapshot; same output values.
assert received[0].to_dict() == result.to_dict()
assert result.payload["host_calculation"]["quality_accepted"] is True
print(result.metrics["rms"], result.payload["host_calculation"])
For streaming input, call analyzer.push(block) and consume the returned list of
completed windows. Gaps, sequence changes, operating identity and clock continuity
matter. analyze(block) handles one complete block directly. Raw-window stages can
implement analyze_window(result, readonly_values) to use calibrated samples instead
of a display-decimated waveform. See composition examples
and the module catalog.
What is implemented
| Area | Available behavior | Required evidence or boundary |
|---|---|---|
| Waveform and spectra | AC RMS, peak, crest, Pearson kurtosis, FFT amplitude, PSD, spectrogram and envelope views | Physical units, sample rate and usable sensor bandwidth |
| Bearing markers | BPFO, BPFI, FTF, BSF and 2BSF from explicit geometry or injected providers | RPM and validated bearing dimensions; ideal kinematics, no slip model |
| Normal reference | Robust feature center/scale, scope checks, relative scores and time-based alarm state | Confirmed normal records separated from threshold calibration and testing |
| Fault candidates | Gaussian baseline, normal-first diagnostics, RPM-conditioned reference bank and morphology head | Experimental; asset, channel, band, duration and speed contracts apply |
| Rule evaluation | Quantity/unit/frame contracts and caller-provided limits | No ISO/KS limit tables are distributed; obtain and assess rules lawfully |
| Optional service | Local HTTP, UDP ingest, SSE, SQLite history and offline UI | Start explicitly; configure authentication before non-local exposure |
Bearing-frequency example
from rotorvibe import BearingGeometry
# Illustrative geometry in a common diameter unit, not a vendor catalog entry.
bearing = BearingGeometry(rolling_elements=8, rolling_diameter=7.0,
pitch_diameter=35.0, contact_angle_deg=0)
print(bearing.frequencies(1200))
Diagnostic states are different outcomes
normal means the applicable normal gate accepted the observation. hold means
there is no supported decision, not that the machine is healthy. anomaly_unknown
means deviation is detected but a trained fault type is not supported.
fault_candidate is a hypothesis within the model's recorded scope, not confirmation
of a physical root cause. Distances and similarity weights are not calibrated fault
probabilities. Keep operational_use=False for the research classifiers.
The morphology head must follow an anomaly gate. A standalone call to
FaultDiscriminator assumes that anomaly screening has already happened; it cannot
identify a healthy class. A two-stage composition
shows the ordering. No downloaded profile is silently enabled.
Evidence: retain the failures
The following experiments have different datasets and protocols. Their percentages must not be merged into a single product accuracy score.
| Historical experiment | Recording-level separation | Observed result | Interpretation |
|---|---|---|---|
| Brito Gaussian comparison | Fixed four-recording final split; subsequently exposed | 63.69% overall; healthy recording 0/420 | Historical reproduction, not field qualification |
| CrossSpeed supported-speed check | 24 held acquisitions after rig-specific fitting | 93.74% of 479 windows | Matched apparatus and own normal reference |
| CrossSpeed 1200 RPM transfer | 59 acquisitions / 1178 windows | 11.04%; all 399 healthy windows anomalous | Cross-speed transfer failed |
| UOS 6204 conditioned model | Eight new source files / 320 windows | 51.88% overall; fault type 48.21% | Better normal reference handling; weak type coverage |
| UOS morphology improvement | Seven new 8 kHz fault files / 560 windows | 559/560 = 99.82%; old comparator 49.11% on the same new files | Same apparatus, bearing and severities; no new healthy test |
| New UOS 30204 bearing domain | Six healthy + seven fault files; all test-only | Strict API: all hold. Offline scope-bypassed stress: healthy 240/240 anomalous, types 124/280 | Generalization failed even after scope bypass |
| Independent UFRJ ABVT rig | Fifteen healthy + fifteen fault files; all test-only | Strict API: all hold. Two predeclared amplitude assumptions: types 0/30 | Unit unresolved; no physical FPR qualification |
In the latest unadapted evaluation, 580 windows all held in the real API. Zero alerts with zero accepted healthy observations does not demonstrate a zero false-alarm rate. The offline stress route is explicitly separate from the product API and must not be used to hide an asset mismatch. UFRJ native CSV units are not explicit in its official page; both fixed amplitude assumptions are reported without choosing one.
The private research workspace passed 547 checks, including its licensed standards
route. That is a historical count, not the public release's test count. Public
release checks are recorded separately in research/public_verification.json; the
normative table tests are excluded and replaced with synthetic caller-rule checks.
Read the latest external assessment and
the evidence index before quoting any performance figure.
Standards and copyright boundary
The private development project investigated ten supplied KS/ISO editions. This
public release deliberately excludes the PDFs, transcriptions, threshold lookup
tables, normative selectors and corresponding table fixtures. vibration.iso now
accepts an explicit custom_rule; it does not select an ISO machine category for you.
The example rules use invented demonstration numbers, not published standard limits.
Independent algorithm implementations, our explanatory comments and our experiment results are released under MIT. The original external measurements, papers, vendor catalogs and standards retain their own terms. Citation identifiers and legal license text are intentionally preserved; third-party substantive prose and figures are not repackaged. See the rights inventory.
Optional dashboard
rotorvibe-monitor --host 127.0.0.1 --port 8765
The service does not simulate measured validation data when no dataset is present.
Use your own live waveform input or explicitly acquired research files. Python hosts
that construct Application must call close() to stop workers and sockets.
VIBRATION_RUNTIME_HOME selects a writable state directory;
VIBRATION_PROJECT_HOME locates separately acquired datasets. Do not point these
variables at confidential data when hosting an externally reachable service.
Published artifacts and documentation versions
Version 0.1.0a1 is public on PyPI,
GitHub Releases and
Zenodo. All three distribute the same
SHA-256-verified wheel and source archive. The GitHub main README includes subsequent
documentation clarifications; immutable 0.1.0a1 archives and their embedded PyPI README
remain the original release snapshot. No numerical model or training data changed.
Reproduce, continue, cite
- Start with synthetic core checks; they need no PDFs or raw data.
- Use the source inventory to acquire external files under their own terms.
- Distinguish historical replay from a new blind test: every previously opened recording is listed as exposed and cannot become a fresh holdout again.
- Freeze model, preprocessing, thresholds, metadata mapping and record membership before opening the next holdout. Audit by original acquisition, not random windows.
- Keep independent normal reference, calibration and final-test records. Record unsupported coverage and false negatives as well as correct classifications.
Continuation instructions identify exact commands, preserved
artifacts, unavailable private components, model hashes and next validation needs.
The archive DOI is 10.5281/zenodo.23937890;
use CITATION.cff for software citation. A DOI identifies an archived release; it
does not certify a diagnostic model.
Copyright © 2026 Ugwiyeon Lee. Original software: MIT.
Metadata
Release files for rotorvibe 0.1.0a5
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| rotorvibe-0.1.0a5.tar.gz | 808.7 kB | With provenance | Details for rotorvibe-0.1.0a5.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| rotorvibe-0.1.0a5-py3-none-any.whl | Python 3 | none | any | Details for rotorvibe-0.1.0a5-py3-none-any.whl |
Total release size: 962.9 kB
Release files / rotorvibe-0.1.0a5.tar.gz
| Download URL | rotorvibe-0.1.0a5.tar.gz |
|---|---|
| Size | 808.7 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
e4b98f4d78a84b47d0bb7f344471f263931f44a1f0a917d3da38478b7b8620b3
|
|
BLAKE2b-256 checksum How to use checksums |
a8455173e92fadc68708095da743047ac3255e751df503fd87310c6ab638b41b
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 4, 2026.
Transparency logRelease files / rotorvibe-0.1.0a5-py3-none-any.whl
| Download URL | rotorvibe-0.1.0a5-py3-none-any.whl |
|---|---|
| Size | 154.2 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
7b800e7b21a610d6cdb1e300893350d07fdc49e4777e4ebb541e62a4d6d1ab20
|
|
BLAKE2b-256 checksum How to use checksums |
adc942739f2cbb5fedd78371f490d755857f3f54a9294aa2ccf2342fbff38f92
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 4, 2026.
Transparency logSecurity for rotorvibe 0.1.0a5
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
Full provenance
Both files in this release have been uploaded with provenance metadata.
Attestation for rotorvibe-0.1.0a5.tar.gz
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 4, 2026.
Transparency logA note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.