Skip to main content

sensor-sdk

OYMotion sdk for Python

Brief

OYMotion SDK is the software development kit for developers to access OYMotion products.

Contributing

See the contributing guide to learn how to contribute to the repository and the development workflow.

License

MIT


Installation

pip install sensor-sdk 

USB Bluetooth dongle (bumble backend)

When a USB Bluetooth HCI dongle is plugged in and usable by libusb (e.g. Actions 10d7:b012 or 33fa:0012; several dongles can be used at once, each serving one connection), the SDK automatically drives it directly with a bumble host-mode backend instead of the OS Bluetooth stack — no Bluetooth permission prompt, works even when the internal Bluetooth is off, and allows larger ATT MTU. The bleak-bumble backend is vendored into the SDK (sensor/bleak_bumble/, MIT license), and the bumble stack + libusb are declared as regular dependencies — a plain pip install sensor-sdk is all that is needed.

Behavior and controls:

  • With the dependencies installed and a usable dongle present, the backend is selected automatically on all platforms when the SDK starts (native bleak is used otherwise). "Usable" means libusb can open the device: on Windows the dongle must be bound to the WinUSB driver, on Linux the user needs udev permission, on macOS USB access is driverless. Check the active backend with SensorController.getBLEBackendName() ("bumble" / "bleak").
  • SensorController.checkSetupDongle() checks dongle readiness and, when no dongle is usable, runs the bundled setup script with elevation — UAC prompt on Windows (binds the WinUSB driver), sudo on Linux (installs udev rules; the password goes through the controlling terminal, or when there is none — e.g. a GUI app launched without a terminal — a terminal-emulator window is spawned to run the script, falling back to pkexec; a replug may still be required afterwards) — then re-checks and returns "OK: N" (N = number of usable dongles detected) on success or an "Error: ..." string with the system error detail on failure. macOS needs no setup and is check-only. The call blocks while waiting for the elevation prompt. The same logic also lives in sensor_utils.checkSetupDongle(), exported at package top level as sensor.checkSetupDongle() for use without a controller instance. The same scripts (setup_dongle_winusb.ps1, setup_dongle_udev.sh and their driver/rules files) ship inside the wheel under sensor/tools/ and can also be run manually.
  • SENSOR_SDK_BLE_BACKEND=bleak forces the native backend; SENSOR_SDK_BLE_BACKEND=bumble forces the dongle backend on any platform; SENSOR_SDK_BUMBLE_TRANSPORT overrides the bumble transport spec (e.g. usb:0).
  • With the bumble backend, each dongle serves one connection at a time: scanning uses a free dongle and is skipped while all dongles are connected; connections fail fast when no dongle is free. Connection timeout is raised to 25s automatically.

1. Permission

Application will obtain bluetooth permission by itself.

2. Import SDK

from sensor import *

SensorController methods

1. Initalize

SensorControllerInstance = SensorController()

# register scan listener
if not SensorControllerInstance.hasDeviceFoundCallback:
    def on_device_callback(deviceList: List[BLEDevice]):
        # return all devices doesn't connected
        pass
    SensorControllerInstance.onDeviceFoundCallback = on_device_callback

2. Start scan

Use def startScan(period_in_ms: int) -> bool to start scan

success = SensorControllerInstance.startScan(6000)

returns true if start scan success, periodInMS means onDeviceCallback will be called every periodInMS

Use def scan(period_in_ms: int) -> list[BLEDevice] to scan once time

bleDevices = SensorControllerInstance.scan(6000)

The asynchronous variant is asyncScan(period_in_ms: int) -> list[BLEDevice].

3. Stop scan

Use def stopScan() -> None to stop scan

SensorControllerInstance.stopScan()

4. Check scaning

Use property isScanning: bool to check scanning status

isScanning = SensorControllerInstance.isScanning

5. Check if bluetooth is enabled

Use property isEnable: bool to check if bluetooth is enable

isEnable = SensorControllerInstance.isEnable

Use onEnableCallback to be notified when the bluetooth enable state changes:

SensorControllerInstance.onEnableCallback = lambda enabled: print("bluetooth on" if enabled else "bluetooth off")

6. Create SensorProfile

Use def requireSensor(device: BLEDevice) -> SensorProfile | None to create SensorProfile.

If bleDevice is invalid, result is None.

sensorProfile = SensorControllerInstance.requireSensor(bleDevice)

7. Get SensorProfile

Use def getSensor(deviceMac: str) -> SensorProfile | None to get SensorProfile.

If SensorProfile didn't created, result is None.

sensorProfile = SensorControllerInstance.getSensor(bleDevice.Address)

8. Get Connected SensorProfiles

Use def getConnectedSensors() -> list[SensorProfile] to get connected SensorProfiles.

sensorProfiles = SensorControllerInstance.getConnectedSensors()

9. Get Connected BLE Devices

Use def getConnectedDevices() -> list[BLEDevice] to get connected BLE Devices.

bleDevices = SensorControllerInstance.getConnectedDevices()

10. Terminate

Use def terminate() to terminate sdk

def terminate():
    SensorControllerInstance.terminate()
    exit()
    
def main():
    signal.signal(signal.SIGINT, lambda signal, frame: terminate())
    time.sleep(30)
    SensorControllerInstance.terminate()
    
Please MAKE SURE to call terminate when exit main() or press Ctrl+C

SensorProfile methods

11. Initalize

Please register callbacks for SensorProfile

from typing import List
from sensor import SensorProfile, SensorData, DeviceStateEx

sensorProfile = SensorControllerInstance.requireSensor(bleDevice)

# register callbacks
def on_state_changed(sensor: SensorProfile, newState: DeviceStateEx):
    # device state transitions (Connecting/Connected/Ready/Disconnected/...)
    # called synchronously on the SDK state machine; return quickly
    # please do logic when device disconnected unexpected
    pass

def on_error_callback(sensor: SensorProfile, reason: str):
    # called when error occurs (dongle unplugged, reconnect budget exhausted, ...)
    pass

def on_power_changed(sensor: SensorProfile, power: int):
    # callback for get battery level of device, power from 0 - 100
    # (invalid -1 readings are never reported here; getBatteryLevel() may
    # still return -1 when no valid reading is available yet)
    # the reported value is stabilized with a hysteresis band (±2%): it only
    # changes when a new reading differs from the current value by 2 or more,
    # so ±1 jitter is filtered while real drain/charge trends are still tracked
    pass

def on_data_callback(sensor: SensorProfile, data_list: List[SensorData]):
    # called after start data transfer; each invocation delivers the whole
    # batch of SensorData objects parsed together (loop over it to process
    # each one)
    for data in data_list:
        pass

sensorProfile.onStateChanged = on_state_changed
sensorProfile.onErrorCallback = on_error_callback
sensorProfile.onPowerChanged = on_power_changed
sensorProfile.onDataCallback = on_data_callback

Callback threading model:

  • onDataCallback runs on a dedicated single-worker thread pool per profile, so batches are delivered strictly in arrival order.
  • onPowerChanged and onErrorCallback share a multi-worker thread pool.
  • onStateChanged is invoked synchronously.
  • Keep callbacks short or thread-safe; update UI through your framework's main-thread mechanism (e.g. Qt signals).

A fifth callback, onAutoReconnect, customizes stream recovery after an abnormal disconnect — see section 15.1.

12. Connect device

Use def connect() -> bool to connect.

success = sensorProfile.connect()

13. Disconnect

Use def disconnect() -> bool to disconnect.

If data notification is currently active, disconnect() will automatically stop it first before closing the BLE connection.

success = sensorProfile.disconnect()

14. Get device status

Use property deviceState: DeviceStateEx to get device status.

Please send command in 'Ready' state, should be after connect() return True.

deviceStateEx = sensorProfile.deviceState

# deviceStateEx has define:
# class DeviceStateEx(Enum):
#     Disconnected = 0
#     Connecting = 1
#     Connected = 2
#     Ready = 3
#     Disconnecting = 4
#     Invalid = 5

15. Get BLE device of SensorProfile

Use property BLEDevice: BLEDevice to get BLE device of SensorProfile.

bleDevice = sensorProfile.BLEDevice

15.1 Auto reconnect and resume data stream

Use property autoReconnect: bool (default True) to control automatic recovery. While True and the device is streaming, an abnormal disconnect — remote link loss or a long no-data (half-dead link) disconnect — is followed by automatic reconnect → init() with the previous init arguments → re-applying the setParam parameters from the previous streaming session (in the order they were set) → startDataNotification(). Recovery retries on the next successful reconnect if a step fails. Explicit user calls (connect(), disconnect(), stopDataNotification()) cancel the pending resume, and setting autoReconnect = False disables the behavior entirely.

sensorProfile.autoReconnect = True   # default; set False to opt out

Custom recovery via onAutoReconnect (default None): when the auto-reconnect finds the disconnected device again (back in Ready, about to resume), this callback is invoked instead of the default flow.

def on_reconnect(sensor, restore: bool) -> bool:
    # restore=True  -> a previous session exists (init args + setParam values can be
    #                  preserved and restored); restore=False -> fresh-init case
    # return True   -> the app handled recovery itself (fresh init or custom flow);
    #                  the SDK skips the default recovery
    # return False  -> fall back to the default flow (connect -> init -> replay
    #                  setParam values -> startDataNotification)
    sensor.init(32, 60000)
    sensor.startDataNotification()
    return True

sensorProfile.onAutoReconnect = on_reconnect

Callback exceptions are logged and treated as False (fall back). The callback runs on the SDK recovery thread, so blocking calls (init(), setParam(), startDataNotification()) are allowed inside it.

16. Get device info of SensorProfile

Use def getDeviceInfo() -> DeviceInfo | None to get device info of SensorProfile.

Please call after device in 'Ready' state and init() has succeeded, returns None otherwise.

    deviceInfo = sensorProfile.getDeviceInfo()

# deviceInfo is a DeviceInfo object with attributes:
#   DeviceName, ModelName, HardwareVersion, FirmwareVersion, MTUSize
#   plus a ChannelCount / SampleRate attribute pair for each modality:
#   Ppg, Spo2, Impe, Emg, Eeg, Ecg, Acc, Gyro, Brth, MagAngle, Euler, Quat
# e.g. deviceInfo.EmgChannelCount, deviceInfo.EegSampleRate

17. Init data transfer

Use def init(packageSampleCount: int, powerRefreshInterval: int) -> bool.

Please call after device in 'Ready' state, return True if init succeed.

success = sensorProfile.init(5, 60*1000)

packageSampleCount: set sample counts of SensorData.channelSamples per batch in onDataCallback() powerRefreshInterval: callback period for onPowerChanged()

18. Check if init data transfer succeed

Use property hasInited: bool to check if init data transfer succeed.

hasInited = sensorProfile.hasInited

19. DataNotify

Use def startDataNotification() -> bool to start data notification.

Please call if hasInited return True

19.1 Start data transfer

success = sensorProfile.startDataNotification()

Data type list:

class DataType(Enum):
    NTF_ACC = 0x1            # acceleration, unit is g
    NTF_GYRO = 0x2           # gyroscope, unit is degree/s
    NTF_EULER_DATA = 0x4     # euler angle, unit is degree
    NTF_QUATERNION = 0x5     # quaternion (w, x, y, z)
    NTF_GEST = 0x07          # gesture id
    NTF_EMG = 0x8            # unit is uV
    NTF_MAG_ANGLE_DATA = 0x0D
    NTF_EEG = 0x10           # unit is uV
    NTF_ECG = 0x11           # unit is uV
    NTF_IMPEDANCE = 0x12     # electrode impedance
    NTF_IMU = 0x13           # aggregated IMU batch (acc 0-2 / gyro 3-5 / euler 6-8 / quat 9-12;
                             # new-EMG devices only, see DeviceInfo.ImuChannelCount)
    NTF_ADS = 0x14
    NTF_BRTH = 0x15          # respiration, unit is uV
    NTF_IMPEDANCE_EXT = 0x16
    NTF_SPO2 = 0x17          # SpO2 percentage
    NTF_PPG = 0x18           # PPG raw samples

Process data in onDataCallback. Each invocation delivers a list of SensorData batches parsed together; loop over the list to process each batch.

def on_data_callback(sensor: SensorProfile, data_list: List[SensorData]):
    for data in data_list:
        if data.dataType == DataType.NTF_EEG:
            pass
        elif data.dataType == DataType.NTF_ECG:
            pass

        # process data as you wish
        for oneChannelSamples in data.channelSamples:
            for sample in oneChannelSamples:
                if sample.isLost:
                    # do some logic
                    pass
                else:
                    # draw with sample.data & sample.channelIndex
                    # print(f"{sample.channelIndex} | {sample.sampleIndex} | {sample.data} | {sample.impedance}")
                    pass

sensorProfile.onDataCallback = on_data_callback

19.2 Stop data transfer

Use def stopDataNotification() -> bool to stop data transfer.

success = sensorProfile.stopDataNotification()

19.3 Check if it's data transfering

Use property isDataTransfering: bool to check if it's data transfering.

isDataTransfering = sensorProfile.isDataTransfering

20. Get battery level

Use def getBatteryLevel() -> int to get battery level. Please call after device in 'Ready' state.

batteryPower = sensorProfile.getBatteryLevel()

# batteryPower is battery level returned, value ranges from 0 to 100, 0 means out of battery, while 100 means full;
# -1 means no valid reading is available yet (onPowerChanged never reports -1).

Please check console.py in examples directory

Async methods

all methods start with async is async methods, they has same params and return result as sync methods.

Please check async_console.py in examples directory

setParam method

Use def setParam(self, key: str, value: str) -> str to set parameter of sensor profile. Please call after device in 'Ready' state.

The asynchronous variant is asyncSetParam(self, key: str, value: str) -> str.

If the device is already streaming when you change an NTF_* or FILTER_* key, the SDK will stop and restart the data notification so the new setting takes effect immediately.

Below is available key and value:

# Data stream toggles
result = sensorProfile.setParam("NTF_GEST", "ON")
result = sensorProfile.setParam("NTF_EMG", "ON")
result = sensorProfile.setParam("NTF_EEG", "ON")
result = sensorProfile.setParam("NTF_ECG", "ON")
result = sensorProfile.setParam("NTF_IMU", "ON")
result = sensorProfile.setParam("NTF_BRTH", "ON")
result = sensorProfile.setParam("NTF_IMPEDANCE", "ON")
result = sensorProfile.setParam("NTF_MAG_ANGLE", "ON")
result = sensorProfile.setParam("NTF_PPG", "ON")
result = sensorProfile.setParam("NTF_PPG_RAW", "ON")   # alias of NTF_PPG
result = sensorProfile.setParam("NTF_SPO2", "ON")
result = sensorProfile.setParam("NTF_GFORCE_EULER", "ON")
result = sensorProfile.setParam("NTF_GFORCE_QUAT", "ON")
result = sensorProfile.setParam("NTF_GFORCE_ACC", "ON")
result = sensorProfile.setParam("NTF_GFORCE_GYRO", "ON")
# set data stream to ON or OFF, result is "OK" if succeed
# NTF_IMU is the master switch of the four NTF_GFORCE_* streams: toggling it
# updates all four, and toggling any of the four updates the aggregated NTF_IMU state.
# Note: on legacy (non-new) EMG devices, NTF_GEST and NTF_EMG are mutually exclusive.

# Firmware filter toggles
result = sensorProfile.setParam("FILTER_50HZ", "ON")
# set 50Hz notch filter to ON or OFF, result is "OK" if succeed

result = sensorProfile.setParam("FILTER_60HZ", "ON")
# set 60Hz notch filter to ON or OFF, result is "OK" if succeed

result = sensorProfile.setParam("FILTER_HPF", "ON")
# set 0.5Hz hpf filter to ON or OFF, result is "OK" if succeed

result = sensorProfile.setParam("FILTER_LPF", "ON")
# set 80Hz lpf filter to ON or OFF, result is "OK" if succeed

# NeuCir remote control (NeuCir devices only)
result = sensorProfile.setParam("NEUCIR_SET_MODE", "APP_REMOTE")
result = sensorProfile.setParam("NEUCIR_APP_CONTROL", "OPEN")   # OPEN / CLOSE / STOP

result = sensorProfile.setParam("DEBUG_BLE_DATA_PATH", "d:/temp/test.bin")
# set the bin export path: the session's raw BLE capture is recorded in the system
# temp directory and copied to this location on stopDataNotification / disconnect;
# "True" exports to {DeviceName}_data_YYYYMMDD_HHMMSS.bin in the SDK log directory
# (see setLogPath; disabled when file output is off), "False" or "" disables
# export (the temp bin is just deleted).
# please give an absolute path and make sure it is valid and writeable by yourself

result = sensorProfile.setParam("DEBUG_LOG_PATH", "True")
# enable this profile's log file: {DeviceName}_log_YYYYMMDD_HHMMSS.txt in the SDK
# log directory (see setLogPath), or pass an absolute custom path instead of "True";
# "False" or "" disables it. The profile log contains only this profile's logs plus
# the bleak/bumble logs related to its current connection; all other (common) logs
# go to the controller log.
# getParam("DEBUG_LOG_PATH") returns the current log file path ("" when disabled).

getParam method

Use def getParam(self, key: str) -> str to query the current parameter state of a sensor profile. Please call after the device reaches the 'Ready' state.

The asynchronous variant is asyncGetParam(self, key: str) -> str.

Supported aggregate query keys:

result = sensorProfile.getParam("FILTER")
# Returns a pipe-separated string of all filter states, e.g.:
# "FILTER_50HZ|ON|FILTER_60HZ|ON|FILTER_HPF|ON|FILTER_LPF|ON"

result = sensorProfile.getParam("NTF")
# Returns a pipe-separated string of all notification states, e.g.:
# "NTF_BRTH|ON|NTF_ECG|ON|NTF_EEG|ON|NTF_EMG|ON|..."

If the key is not supported, the result starts with "Error".

Bin file recording and replay

On every successful connect, the SDK records all raw BLE packets of the session into a .bin file in the SDK log directory (~/Documents/sensorsdklog by default, or the directory of the configured log file), named {DeviceName}_{MAC}_{YYYYMMDD_HHMMSS}.bin. Recording is always on; it is skipped or stopped with a warning when free disk space is below 100MB or a disk error occurs, without affecting live streaming. Bin files can be replayed offline for debugging and packet-loss analysis.

Get bin file info

Use def getBinFileInfo(self, file_path: str) -> Optional[dict] to read the config record of a bin file:

info = SensorControllerInstance.getBinFileInfo("path/to/session.bin")
# Returns a dict:
#   device_mac, device_name, chip_type, is_universal_stream, feature_map,
#   device_info, sensor_datas (per data-type parse config),
#   replay_duration (recording seconds, written into the header record at close;
#                    older bins without a header fall back to a full-file estimate)
# Returns None if the file does not exist or has no config record.

Replay a bin file

Use def replayBinFile(self, file_path: str, sensor: Optional[SensorProfile] = None, realtime: bool = True, timeout: Optional[float] = None) -> Optional[SensorProfile] to replay a bin file through the normal parsing pipeline. Parsed results arrive via onDataCallback on the returned SensorProfile, same as live data.

# Simplest form: controller creates the profile from the bin config record
sensor = SensorControllerInstance.replayBinFile("path/to/session.bin")

# Recommended: reuse an existing profile with callbacks registered
sensor = SensorControllerInstance.requireSensor(device)
sensor.onDataCallback = on_data
SensorControllerInstance.replayBinFile("path/to/session.bin", sensor, realtime=True)
  • sensor: an existing SensorProfile to replay through. When None, the controller creates (or reuses) a profile from the bin config record; in that mode the profile is returned only after replay finishes, so register callbacks on an existing profile to receive data.
  • realtime: True replays at the recorded pace; False replays as fast as possible.
  • timeout: seconds to wait for completion. None auto-estimates from the bin duration in realtime mode (duration + 30s, min 60s), or 600s otherwise. On timeout the call returns while replay may still be running in the background.
  • Replay is rejected while the target sensor is streaming live data.

Pause / resume / stop replay

result = SensorControllerInstance.pauseBinReplay(sensor)   # pause feeding
result = SensorControllerInstance.resumeBinReplay(sensor)  # resume feeding
result = SensorControllerInstance.stopBinReplay(sensor)    # abort; the blocking replayBinFile call returns
# Each returns "OK" on success or an error string otherwise.

Parse a bin file to CSV

Use def parseBinToCsv(self, bin_path: str, csv_path: Optional[str] = None) -> str to convert a recorded bin file to CSV offline (parsing runs through the real pipeline; row timestamps come from the bin records):

csv_path = SensorControllerInstance.parseBinToCsv("d:/temp/test.bin")
# or with an explicit output path:
csv_path = SensorControllerInstance.parseBinToCsv("d:/temp/test.bin", "d:/temp/test.csv")
# Returns the CSV file path.

CSV format — header row:

timestamp,mac,type,raw_hex,data_type,sample_rate,channel_count,lost_count,samples_info,first_sample

Row kinds in record order (config records produce no rows; a bin without a config record yields raw rows only):

  • raw rows — one per data record: timestamp = ISO 8601 (local time) of the bin record timestamp, mac (empty for records before the first config record), type = raw, raw_hex = raw packet bytes as hex; remaining columns empty.
  • cmd_send / cmd_recv rows — one per command record: type = cmd_send / cmd_recv, raw_hex = command bytes as hex, data_type = decoded command name (cmd_send, e.g. NTF_DATA_START) or NAME:CODE (cmd_recv, e.g. GET_FEATURE_MAP:SUCCESS); remaining columns empty. These rows are analysis-only and are not fed into parsing.
  • event rows — one per BLE event record: type = event, raw_hex = event name as hex, data_type = event name (connect / disconnect / stream_start / stream_stop); remaining columns empty.
  • parsed rows — one per parsed batch emitted by the real parsing pipeline (raw_hex empty):
Column Meaning
timestamp ISO 8601 (local time) of the bin record being fed when the batch completed
mac Device MAC from the config record
type parsed
data_type DataType enum name of the batch, e.g. NTF_EMG, NTF_EEG, NTF_ACC
sample_rate Batch sample rate (Hz)
channel_count Batch channel count
lost_count lostPackageCount of the batch (non-zero only for new-EMG devices)
samples_info Per-channel sample counts as a Python list string, e.g. [32, 32, 32]
first_sample First sample of the first non-empty channel: data=<v>|raw=<raw>|imp=<impedance>|sat=<saturation>|idx=<sampleIndex>|ts=<timeStampInMs>|ch=<channelIndex>|lost=<isLost>

Logging controls

setLogPath sets the SDK log directory (it must be a directory). All default file outputs live in it: the controller log, the default per-profile logs (DEBUG_LOG_PATH=True) and the default bin exports (DEBUG_BLE_DATA_PATH=True).

The controller log (sensor_controller_log_YYYYMMDD_HHMMSS.txt) holds all common logs (scan, connection management, dongle/backend, and logs of profiles whose profile log is not enabled). It is created automatically in the log directory when setDebugEnabled(True) is called, and closed on setDebugEnabled(False). Each profile log ({DeviceName}_log_YYYYMMDD_HHMMSS.txt, enabled per profile via setParam("DEBUG_LOG_PATH", ...)) contains only that profile's logs plus the bleak/bumble logs related to its current connection.

Records emitted before a log file is first created are held in a bounded memory buffer and replayed into the file on creation, so early (scan/connect) logs are not lost. The log directory and debug switch are automatically shared with the BLE subprocess, so both sides append to the same files.

SensorControllerInstance.setDebugEnabled(True)
# enable SDK debug logs; automatically creates the controller log in the log
# directory. setDebugEnabled(False) closes it.

SensorControllerInstance.setLogPath(True, "d:/temp/sdklogs")
# set the log directory (must be a directory; created if missing, rejected if
# it points to an existing file). setLogPath(False) disables file output
# (controller log, default profile logs and default bin exports).

SensorControllerInstance.setLogPath(True)
# reset to the default log directory (~/Documents/sensorsdklog)

Metadata

Release files for sensor-sdk 0.5.1

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Built distributions (wheels)

Table of built distributions (wheels) for sensor-sdk 0.5.1
File Actions
sensor_sdk-0.5.1-cp313-cp313-win_amd64.whl CPython 3.13 CPython 3.13 Windows x86-64 Details for sensor_sdk-0.5.1-cp313-cp313-win_amd64.whl
sensor_sdk-0.5.1-cp313-cp313-manylinux_2_28_x86_64.whl CPython 3.13 CPython 3.13 Linux glibc 2.28+ x86-64 Details for sensor_sdk-0.5.1-cp313-cp313-manylinux_2_28_x86_64.whl
sensor_sdk-0.5.1-cp313-cp313-macosx_12_0_arm64.whl CPython 3.13 CPython 3.13 macOS 12.0+ ARM64 Details for sensor_sdk-0.5.1-cp313-cp313-macosx_12_0_arm64.whl
sensor_sdk-0.5.1-cp312-cp312-win_amd64.whl CPython 3.12 CPython 3.12 Windows x86-64 Details for sensor_sdk-0.5.1-cp312-cp312-win_amd64.whl
sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_x86_64.whl CPython 3.12 CPython 3.12 Linux glibc 2.28+ x86-64 Details for sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_x86_64.whl
sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_aarch64.whl CPython 3.12 CPython 3.12 Linux glibc 2.28+ ARM64 Details for sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_aarch64.whl
sensor_sdk-0.5.1-cp312-cp312-macosx_12_0_arm64.whl CPython 3.12 CPython 3.12 macOS 12.0+ ARM64 Details for sensor_sdk-0.5.1-cp312-cp312-macosx_12_0_arm64.whl
sensor_sdk-0.5.1-cp311-cp311-win_amd64.whl CPython 3.11 CPython 3.11 Windows x86-64 Details for sensor_sdk-0.5.1-cp311-cp311-win_amd64.whl
sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_x86_64.whl CPython 3.11 CPython 3.11 Linux glibc 2.28+ x86-64 Details for sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_x86_64.whl
sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_aarch64.whl CPython 3.11 CPython 3.11 Linux glibc 2.28+ ARM64 Details for sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_aarch64.whl
sensor_sdk-0.5.1-cp311-cp311-macosx_12_0_arm64.whl CPython 3.11 CPython 3.11 macOS 12.0+ ARM64 Details for sensor_sdk-0.5.1-cp311-cp311-macosx_12_0_arm64.whl
sensor_sdk-0.5.1-cp310-cp310-win_amd64.whl CPython 3.10 CPython 3.10 Windows x86-64 Details for sensor_sdk-0.5.1-cp310-cp310-win_amd64.whl
sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_x86_64.whl CPython 3.10 CPython 3.10 Linux glibc 2.28+ x86-64 Details for sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_x86_64.whl
sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_aarch64.whl CPython 3.10 CPython 3.10 Linux glibc 2.28+ ARM64 Details for sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_aarch64.whl
sensor_sdk-0.5.1-cp310-cp310-macosx_12_0_arm64.whl CPython 3.10 CPython 3.10 macOS 12.0+ ARM64 Details for sensor_sdk-0.5.1-cp310-cp310-macosx_12_0_arm64.whl

Total release size: 127.2 MB

Release files / sensor_sdk-0.5.1-cp313-cp313-win_amd64.whl

Download URL sensor_sdk-0.5.1-cp313-cp313-win_amd64.whl
Size 1.9 MB
Tags CPython 3.13 Windows x86-64
SHA-256 checksum
How to use checksums
a7734830cdbc955a5b7e5af0c668192663b6907800862d9fcea0a78df298e1ba
BLAKE2b-256 checksum
How to use checksums
97c4c2daeec124e29fb44dc1f343af52385570ce13a3d2114a9c4f88ac95955e
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp313-cp313-manylinux_2_28_x86_64.whl

Download URL sensor_sdk-0.5.1-cp313-cp313-manylinux_2_28_x86_64.whl
Size 15.9 MB
Tags CPython 3.13 Linux glibc 2.28+ x86-64
SHA-256 checksum
How to use checksums
b08cc71532b73b509cef8b74371886876e10213a48c96c27811e30c43fa1603c
BLAKE2b-256 checksum
How to use checksums
f63d00fb00ea82c0b91be9a028f75472b4b5032c9a1f044ef7c020580e21d5d9
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp313-cp313-macosx_12_0_arm64.whl

Download URL sensor_sdk-0.5.1-cp313-cp313-macosx_12_0_arm64.whl
Size 2.0 MB
Tags CPython 3.13 macOS 12.0+ ARM64
SHA-256 checksum
How to use checksums
eb3483bb7ed84c1e712859f8fd9a610b830695ee87a50818dfc8c47e65947e53
BLAKE2b-256 checksum
How to use checksums
1f47533dad0c3a2e096bcd21f9cde1076b1970a8d66abe9ed526f2597171434b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Release files / sensor_sdk-0.5.1-cp312-cp312-win_amd64.whl

Download URL sensor_sdk-0.5.1-cp312-cp312-win_amd64.whl
Size 1.9 MB
Tags CPython 3.12 Windows x86-64
SHA-256 checksum
How to use checksums
a2537a9c4b188c6ff7eb4b9c73df5382b596548c2548f65a0af2b85e359194f9
BLAKE2b-256 checksum
How to use checksums
348a3657a0a0ec0f839b2856606e2263d7c8509a1ccf844393d1b2daeea3f95b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_x86_64.whl

Download URL sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_x86_64.whl
Size 16.0 MB
Tags CPython 3.12 Linux glibc 2.28+ x86-64
SHA-256 checksum
How to use checksums
0de061085733f741c6765d4af5076356c39a7e89f4e55e455bf3da2d5a0f05bd
BLAKE2b-256 checksum
How to use checksums
2c6bb6372c62a19ee1988e261a844aec39cfb47ac0050e16363c3ad97865030b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_aarch64.whl

Download URL sensor_sdk-0.5.1-cp312-cp312-manylinux_2_28_aarch64.whl
Size 15.5 MB
Tags CPython 3.12 Linux glibc 2.28+ ARM64
SHA-256 checksum
How to use checksums
41839d89652948657c15c4b082cf37a8e411b2eedb8ee4578cf3ec3844f9e7bd
BLAKE2b-256 checksum
How to use checksums
996b0fb30327ab71d6e4b21c4a3a5cf6126a3fa5acd81353000fa728c56b6a4c
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Release files / sensor_sdk-0.5.1-cp312-cp312-macosx_12_0_arm64.whl

Download URL sensor_sdk-0.5.1-cp312-cp312-macosx_12_0_arm64.whl
Size 2.0 MB
Tags CPython 3.12 macOS 12.0+ ARM64
SHA-256 checksum
How to use checksums
53f71cfb56fcf890a3eef4c5846e433df544a8f02a41dedcf93b13b5e1b6748e
BLAKE2b-256 checksum
How to use checksums
430f9a92708bfcf433a7ea066a44a729548d1a1bf2bf97a960650da1cfd7747b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Release files / sensor_sdk-0.5.1-cp311-cp311-win_amd64.whl

Download URL sensor_sdk-0.5.1-cp311-cp311-win_amd64.whl
Size 2.0 MB
Tags CPython 3.11 Windows x86-64
SHA-256 checksum
How to use checksums
8475256eded83320576cabb898467f3acebbcdaca5f08e1459f631dcc8a52dc7
BLAKE2b-256 checksum
How to use checksums
d228b3855559247d235d3d8407d53dfa2e6c61c5e63277b5adf7eafb52e1c38d
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_x86_64.whl

Download URL sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_x86_64.whl
Size 16.5 MB
Tags CPython 3.11 Linux glibc 2.28+ x86-64
SHA-256 checksum
How to use checksums
90e169307ce61a5a1a972928b4069eb985b545e60f39975dab7e42f5a1ad4015
BLAKE2b-256 checksum
How to use checksums
5ed89ce1082961d9cf75d5cef4e1e397a144008b23470a876f59466a764b7b58
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_aarch64.whl

Download URL sensor_sdk-0.5.1-cp311-cp311-manylinux_2_28_aarch64.whl
Size 16.3 MB
Tags CPython 3.11 Linux glibc 2.28+ ARM64
SHA-256 checksum
How to use checksums
88e485c74aa7a8a3b83ba7a21be11b9c688f21cdd5a84d3b742f7e81bf139b29
BLAKE2b-256 checksum
How to use checksums
cab5192f1d6a6546577de56e0c5b89d0cd2e43277208d9b762bec278e39cd37f
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Release files / sensor_sdk-0.5.1-cp311-cp311-macosx_12_0_arm64.whl

Download URL sensor_sdk-0.5.1-cp311-cp311-macosx_12_0_arm64.whl
Size 2.0 MB
Tags CPython 3.11 macOS 12.0+ ARM64
SHA-256 checksum
How to use checksums
c5e94803c466ce9d8e4b5e3337ee8b76dbd5b0fac8bd99f28ce69f5a315116a1
BLAKE2b-256 checksum
How to use checksums
2f2f621521c3dcf0e4c23442ea8a395072053f6789940a52d85a4cab7d333f27
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Release files / sensor_sdk-0.5.1-cp310-cp310-win_amd64.whl

Download URL sensor_sdk-0.5.1-cp310-cp310-win_amd64.whl
Size 2.0 MB
Tags CPython 3.10 Windows x86-64
SHA-256 checksum
How to use checksums
73ff4db82df4999903d301062756c8636ac1f781c5b88a75b47336171b0c2668
BLAKE2b-256 checksum
How to use checksums
4761aafa6c46ccc2187999f470036264ea627021948551039334b105ae375374
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_x86_64.whl

Download URL sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_x86_64.whl
Size 15.7 MB
Tags CPython 3.10 Linux glibc 2.28+ x86-64
SHA-256 checksum
How to use checksums
b05933740e7422c44637c15bcba9dbef1e1dde08183e0eec33be11144e8e774d
BLAKE2b-256 checksum
How to use checksums
b7968462e5549c6fdb29435c0dc5fda5430c90b29599fdc447f987d1236c2d9e
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.10

Release files / sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_aarch64.whl

Download URL sensor_sdk-0.5.1-cp310-cp310-manylinux_2_28_aarch64.whl
Size 15.4 MB
Tags CPython 3.10 Linux glibc 2.28+ ARM64
SHA-256 checksum
How to use checksums
1be6bc7031d9ed59be979f80bcfbf98d467d8bff2347573a7a49c14d5836e496
BLAKE2b-256 checksum
How to use checksums
7570146d16b6de8a5a0fcab80809bb2e0c8653e78eefb8fbd991dd2762dcf18e
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Release files / sensor_sdk-0.5.1-cp310-cp310-macosx_12_0_arm64.whl

Download URL sensor_sdk-0.5.1-cp310-cp310-macosx_12_0_arm64.whl
Size 2.1 MB
Tags CPython 3.10 macOS 12.0+ ARM64
SHA-256 checksum
How to use checksums
011ed4d8af63d00aa15378b8f4586b3f8cf7f55f5c84c675704a0bc23b5b2b58
BLAKE2b-256 checksum
How to use checksums
f56393bbcb819c2eec84353894a59537b424a731fc7f26ec510b7ae676f4808c
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.13.9

Security for sensor-sdk 0.5.1

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

No provenance found

None of the files in this release were uploaded with provenance metadata.

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Release history Release notifications | RSS feed

This release

0.5.1 This release

15 release files No provenance

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page