Skip to main content

A Prometheus Exporter for the SunPower PVS Device

Project description

About

A Prometheus exporter for the SunPower ProVision monitoring system:

  • SunPower PVS 5x
  • SunPower PVS 6

Requirements

  • Python 2.7+
  • Prometheus Client

Installation

From pip:

pip install sunpower_pvs_exporter

From github:

# pip install git@github.apple.com:ginoledesma/sunpower-pvs-exporter.git
pip install sunpower_pvs_exporter

Usage

Help

$ sunpower-pvs-exporter -h 
usage: sunpower-pvs-exporter [-h] [--hostname HOSTNAME] [--port PORT]
                             [--use-tls] [--listen-on LISTEN_ON]
                             [--log-file LOG_FILE]
                             [--log-level {ERROR,WARNING,INFO,DEBUG}]
                             [--timeout TIMEOUT] [--use-device-data-timestamp]

optional arguments:
  -h, --help            show this help message and exit
  --hostname HOSTNAME   SunPower PV Supervisor hostname
  --port PORT           SunPower PV Supervisor port
  --use-tls             Use SSL/TLS when communicating with SunPower PV
                        Supervisor
  --listen-on LISTEN_ON
                        Listen on the specified port
  --log-file LOG_FILE   Output logfile
  --log-level {ERROR,WARNING,INFO,DEBUG}
                        Log level
  --timeout TIMEOUT     Connection timeout value (in seconds)
  --use-device-data-timestamp
                        Use the data timestamp from the PVS device

Runtime

$ sunpower-pvs-exporter
2019-05-13 20:13:48,701 Listening on port 9110...

$ curl http://localhost:9110/
# HELP python_info Python platform information
# TYPE python_info gauge
python_info{implementation="CPython",major="2",minor="7",patchlevel="10",version="2.7.10"} 1.0
# HELP sunpower_pvs_communication_interface_info Communications Interface Information
# TYPE sunpower_pvs_communication_interface_info gauge
sunpower_pvs_communication_interface_info{interface="wan",internet="up",sms="reachable"} 1.0
sunpower_pvs_communication_interface_info{interface="plc",internet="down",sms="unreachable"} 1.0
sunpower_pvs_communication_interface_info{interface="sta0",internet="down",sms="unreachable"} 1.0
sunpower_pvs_communication_interface_info{interface="cell",internet="down",sms="unreachable"} 1.0
# HELP sunpower_pvs_grid_profile_info Grid Profile
# TYPE sunpower_pvs_grid_profile_info gauge
sunpower_pvs_grid_profile_info{id="aabbccddeeffaabbccddeeffaabbccddeeffaabbccd",name="IEEE-1547",percent="100",status="success"} 1.0
# HELP sunpower_pvs_supervisor_communication_errors_total Total number of communication errors
# TYPE sunpower_pvs_supervisor_communication_errors_total counter
sunpower_pvs_supervisor_communication_errors_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 283.0
# HELP sunpower_pvs_supervisor_cpu_loadavg CPU Load Average
# TYPE sunpower_pvs_supervisor_cpu_loadavg gauge
sunpower_pvs_supervisor_cpu_loadavg{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.2
# HELP sunpower_pvs_supervisor_errors_total Total number of errors
# TYPE sunpower_pvs_supervisor_errors_total counter
sunpower_pvs_supervisor_errors_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.0
# HELP sunpower_pvs_supervisor_flash_storage_available_bytes Storage available space (bytes)
# TYPE sunpower_pvs_supervisor_flash_storage_available_bytes gauge
sunpower_pvs_supervisor_flash_storage_available_bytes{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 7.8512128e+07
# HELP sunpower_pvs_supervisor_mem_used_bytes Memory used (bytes)
# TYPE sunpower_pvs_supervisor_mem_used_bytes gauge
sunpower_pvs_supervisor_mem_used_bytes{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 3.9350272e+07
# HELP sunpower_pvs_supervisor_scan_time_seconds Scan time
# TYPE sunpower_pvs_supervisor_scan_time_seconds gauge
sunpower_pvs_supervisor_scan_time_seconds{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.0
# HELP sunpower_pvs_supervisor_skipped_scans_total Skipped scans
# TYPE sunpower_pvs_supervisor_skipped_scans_total counter
sunpower_pvs_supervisor_skipped_scans_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 0.0
# HELP sunpower_pvs_supervisor_untransmitted_events_total Untransmitted events
# TYPE sunpower_pvs_supervisor_untransmitted_events_total counter
sunpower_pvs_supervisor_untransmitted_events_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 9510.0
# HELP sunpower_pvs_supervisor_uptime_seconds_total Uptime (seconds)
# TYPE sunpower_pvs_supervisor_uptime_seconds_total counter
sunpower_pvs_supervisor_uptime_seconds_total{device_id="ZT01234567890123456",model="PV Supervisor PVS6",software_version="2019.5, Build 4150"} 10494.0
# HELP sunpower_pvs_power_meter_ct_rated_current_amperes CT Rated Current
# TYPE sunpower_pvs_power_meter_ct_rated_current_amperes gauge
sunpower_pvs_power_meter_ct_rated_current_amperes{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 50.0
sunpower_pvs_power_meter_ct_rated_current_amperes{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 100.0
# HELP sunpower_pvs_power_meter_ac_frequency_hertz AC Frequency
# TYPE sunpower_pvs_power_meter_ac_frequency_hertz gauge
sunpower_pvs_power_meter_ac_frequency_hertz{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 60.0
sunpower_pvs_power_meter_ac_frequency_hertz{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 60.0
# HELP sunpower_pvs_power_meter_net_energy_watt_hours Total Net Energy
# TYPE sunpower_pvs_power_meter_net_energy_watt_hours gauge
sunpower_pvs_power_meter_net_energy_watt_hours{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 294370.0
sunpower_pvs_power_meter_net_energy_watt_hours{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} -103980.0
# HELP sunpower_pvs_power_meter_average_real_power_watts Average real power
# TYPE sunpower_pvs_power_meter_average_real_power_watts gauge
sunpower_pvs_power_meter_average_real_power_watts{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 9.0
sunpower_pvs_power_meter_average_real_power_watts{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 464.1
# HELP sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive Average reactive power
# TYPE sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive gauge
sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 328.0
sunpower_pvs_power_meter_average_reactive_power_volt_amperes_reactive{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} -915.6
# HELP sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive Average reactive power
# TYPE sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive gauge
sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 329.40000000000003
sunpower_pvs_power_meter_average_apparent_power_volt_amperes_reactive{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 1077.3999999999999
# HELP sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power Power Factor (Real Power / Apparent Power) ratio
# TYPE sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power gauge
sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power{ct_rated_current="50",description="Power Meter PVS6M01234567p",device_id="PVS6M01234567p",mode="production",model="PVS6M0001p",port="",software_version="3000",type="PVS5-METER-P"} 0.0241
sunpower_pvs_power_meter_power_factor_real_power_per_apparent_power{ct_rated_current="100",description="Power Meter PVS6M01234567c",device_id="PVS6M01234567c",mode="consumption",model="PVS6M0001c",port="",software_version="3000",type="PVS5-METER-C"} 0.4302
# HELP sunpower_pvs_inverter_ac_current_amperes AC Current
# TYPE sunpower_pvs_inverter_ac_current_amperes gauge
sunpower_pvs_inverter_ac_current_amperes{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
sunpower_pvs_inverter_ac_current_amperes{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
sunpower_pvs_inverter_ac_current_amperes{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
# HELP sunpower_pvs_inverter_ac_power_watts AC Power
# TYPE sunpower_pvs_inverter_ac_power_watts gauge
sunpower_pvs_inverter_ac_power_watts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.1
sunpower_pvs_inverter_ac_power_watts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.4
sunpower_pvs_inverter_ac_power_watts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.0
# HELP sunpower_pvs_inverter_ac_voltage_volts AC Voltage
# TYPE sunpower_pvs_inverter_ac_voltage_volts gauge
sunpower_pvs_inverter_ac_voltage_volts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 250.48
sunpower_pvs_inverter_ac_voltage_volts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 249.98
sunpower_pvs_inverter_ac_voltage_volts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 250.16
# HELP sunpower_pvs_inverter_dc_current_amperes DC Current
# TYPE sunpower_pvs_inverter_dc_current_amperes gauge
sunpower_pvs_inverter_dc_current_amperes{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.01
sunpower_pvs_inverter_dc_current_amperes{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.03
sunpower_pvs_inverter_dc_current_amperes{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.03
# HELP sunpower_pvs_inverter_dc_power_watts DC Power
# TYPE sunpower_pvs_inverter_dc_power_watts gauge
sunpower_pvs_inverter_dc_power_watts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 0.1
sunpower_pvs_inverter_dc_power_watts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 0.6
sunpower_pvs_inverter_dc_power_watts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 0.8
# HELP sunpower_pvs_inverter_dc_voltage_volts DC Voltage
# TYPE sunpower_pvs_inverter_dc_voltage_volts gauge
sunpower_pvs_inverter_dc_voltage_volts{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 10.12
sunpower_pvs_inverter_dc_voltage_volts{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 21.99
sunpower_pvs_inverter_dc_voltage_volts{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 21.99
# HELP sunpower_pvs_inverter_operating_frequency_hertz Operating Frequency (hertz)
# TYPE sunpower_pvs_inverter_operating_frequency_hertz gauge
sunpower_pvs_inverter_operating_frequency_hertz{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 60.19
sunpower_pvs_inverter_operating_frequency_hertz{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 59.98
sunpower_pvs_inverter_operating_frequency_hertz{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 59.98
# HELP sunpower_pvs_inverter_energy_total_watt_hours Total Energy
# TYPE sunpower_pvs_inverter_energy_total_watt_hours gauge
sunpower_pvs_inverter_energy_total_watt_hours{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 19249.9
sunpower_pvs_inverter_energy_total_watt_hours{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 19313.7
sunpower_pvs_inverter_energy_total_watt_hours{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 18932.5
# HELP sunpower_pvs_inverter_heatsink_temperature_celcius Heatsink Temperature
# TYPE sunpower_pvs_inverter_heatsink_temperature_celcius gauge
sunpower_pvs_inverter_heatsink_temperature_celcius{description="Inverter E00000000000001",device_id="E00000000000001",model="AC_Module_Type_E",module_id="P07M20205372",port="",software_version="118079776",type="SOLARBRIDGE"} 22.0
sunpower_pvs_inverter_heatsink_temperature_celcius{description="Inverter E00000000000002",device_id="E00000000000002",model="AC_Module_Type_E",module_id="P07M20205351",port="",software_version="118079776",type="SOLARBRIDGE"} 22.0
sunpower_pvs_inverter_heatsink_temperature_celcius{description="Inverter E00000000000003",device_id="E00000000000003",model="AC_Module_Type_E",module_id="P07M20205226",port="",software_version="118079776",type="SOLARBRIDGE"} 21.0
# HELP sunpower_pvs_device_state Device (Component/Module) State
# TYPE sunpower_pvs_device_state gauge
sunpower_pvs_device_state{device_id="ZT01234567890123456",device_type="PVS",model="PV Supervisor PVS6",software_version="2019.5, Build 4150",state="working",type=""} 1.0
sunpower_pvs_device_state{device_id="PVS6M01234567p",device_type="Power Meter",model="PVS6M0001p",software_version="3000",state="working",type="PVS5-METER-P"} 1.0
sunpower_pvs_device_state{device_id="PVS6M01234567c",device_type="Power Meter",model="PVS6M0001c",software_version="3000",state="working",type="PVS5-METER-C"} 1.0
sunpower_pvs_device_state{device_id="E00000000000001",device_type="Inverter",model="AC_Module_Type_E",software_version="118079776",state="working",type="SOLARBRIDGE"} 1.0
sunpower_pvs_device_state{device_id="E00000000000002",device_type="Inverter",model="AC_Module_Type_E",software_version="118079776",state="working",type="SOLARBRIDGE"} 1.0
sunpower_pvs_device_state{device_id="E00000000000003",device_type="Inverter",model="AC_Module_Type_E",software_version="118079776",state="working",type="SOLARBRIDGE"} 1.0

The --use-device-data-timestamp flag causes the exporter to use the timestamp emitted from the PVS device. This is disabled by default for a few reasons:

  • Setting the timestamp explicitly (instead of having Prometheus do it) is best suited for the Push Gateway

  • Depending on the component, the timestamp value may be too "out-of-date" (for example, the Supervisor component refreshes once every 5 minutes only)

  • The timestamp field may not be available when the device is in an error state

References

See the Notes section for more information.

Example Grafana Dashboards

Summary Dashboard - Panel Config Inverter Dashboard - Panel Config PVS Supervisor Dashboard - Panel Config

Project details


Release history Release notifications | RSS feed

This version

1.0

Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

sunpower_pvs_exporter-1.0.tar.gz (11.6 kB view hashes)

Uploaded Source

Built Distributions

sunpower_pvs_exporter-1.0-py3-none-any.whl (10.2 kB view hashes)

Uploaded Python 3

sunpower_pvs_exporter-1.0-py2-none-any.whl (10.2 kB view hashes)

Uploaded Python 2

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page