Skip to main content

XRDpy

XRDpy is a Python toolkit for X-ray diffraction (XRD) simulation and analysis, with a particular focus on time-resolved / pump-probe diffraction workflows.

The project name on GitHub and Zenodo is XRDpy. The package is distributed on PyPI as trxrdpy and should be imported in Python as trxrdpy.


Repository

Source code: https://github.com/julioguzmanb/XRDpy

DOI (Zenodo)

Manual


Main capabilities

Simulation

  • Polycrystalline XRD simulation, including CIF-based 1D patterns on q, 2θ, or d axes
  • Single-crystal diffraction simulation
  • CIF-based crystallographic helpers
  • Plotting utilities for simulated diffraction data
  • Simulation GUI workflows
  • Matrix-rotation helper GUI

Analysis

  • Facility-specific analysis workflows
  • Metadata-driven data reduction for representative 2D images
  • Single-shot 1D pattern production for Max IV FemtoMAX and SPring-8 SACLA
  • Side-by-side detector-image and pyFAI 2D-cake diagnostics
  • Azimuthal integration from representative 2D images or compatible single-shot 1D caches
  • On-the-fly refresh of final patterns from the completed shots currently available
  • Standardized generation of 1D xy diffraction patterns
  • 1D absolute-pattern and difference-pattern visualization
  • Peak fitting workflows
  • Differential analysis workflows
  • Shared utilities for plotting, path handling, calibration, fitting, and common analysis operations
  • Modular Analysis GUI for ESRF ID09, Max IV FemtoMAX, and SPring-8 SACLA workflows

Installation

From PyPI

pip install trxrdpy

Optional extras:

pip install "trxrdpy[analysis]"
pip install "trxrdpy[gui]"

The GUI extra installs PyQt5 and mplcursors. mplcursors is required for the interactive hover annotations shown in simulation detector/reflection plots.

From source

Clone the repository and install in editable mode:

git clone https://github.com/julioguzmanb/XRDpy.git
cd XRDpy
pip install -e .

For development with analysis and GUI dependencies:

pip install -e ".[analysis,gui]"

Launching the GUIs

Simulation GUI

python3 -m trxrdpy.simulation.gui.main_window

Orientation from measured Bragg peaks

In Single Crystal, select Find Orientation Matrix. Set the unit cell (or load a CIF), detector geometry (or PONI file), energy, sample goniometer, and optional initial orientation in the normal controls. Then use New project from current setup to capture those conditions. A project contains reusable detector setups, linked experimental poses, and any number of observed Bragg pixels per pose.

Add a pose from a selected parent to inherit its energy, detector setup, and motor readings. Select Absolute readings for entered sample motor values or Changes from parent for motor increments. Blank fields inherit. Detector motor readings can also be changed for a pose. Add all peaks observed at that pose as separate rows. An HKL may be exact, any symmetry equivalent of the entered family, or unknown. Update q/d from pixels helps identify a peak from its measured scattering-vector magnitude.

Set default horizontal and vertical peak position uncertainties in Uncertainties, then edit individual peak rows when their precision differs. Detector calibration uncertainty is a separate, shared input. Energy, motor, and lattice uncertainties also weight the fit. Fit crystal orientation ranks candidate assignments, shows pixel residuals and local orientation uncertainty, and reports when the measurements leave a rotation undetermined. Candidate details include the direct-lattice orientation matrix at every recorded pose. Select a candidate and pose, then Update crystal orientation at selected pose to install the corresponding initial orientation and experimental conditions. Projects and fitted results can be saved and loaded separately as JSON.

Two-Parameter Mapping Slices

In Single Crystal, select Motors Mapping for Catching Braggs. The two plotted parameters remain fixed. Under Additional Mapping Sliders, enable Scan additional parameters and add ranges for other sample rotations or sample-chain motors, energy, or full bandwidth (e_bandwidth, in percent). An extra parameter cannot also be one of the plotted axes. This option is off for older GUI states; new states retain the checkbox, ranges, and shared Euler order.

Legacy scans first apply the initial sample orientation, then apply all scan rotation components together in Rotation order beside the legacy sample Euler angles. The table row order does not change rotation order. For motor-chain geometry, the physical chain order is retained and extra motors set the unplotted motor angles.

Unlike the compact reciprocal explorer, this mode computes every requested mapping slice. The amount of work multiplies with each added range. Parallel processing operates on the existing mapping rows, and Stop safely cancels the computation without replacing the previous completed result. Start with coarse extra ranges. Sliders, previous/next buttons, and numeric value boxes select computed slices; they do not repeat the Bragg search. Save Results stores all slices in HDF5, and Load Results restores them independently of the current sample inputs. Points, band outlines, and filled bands remain available. Detector-hit filtering is applied to the displayed slice using the current detector, leaving the saved Bragg results intact.

Mapping renderer selects Matplotlib (the compatible default) or Plotly (browser) and is retained in GUI states. Plotly supports ordinary maps and saved mapping slices, with clickable reflection legends, hover values, sliders, and numeric entry. Points and outlines use WebGL; filled bands use separate occupied-cell polygons so disconnected branches are not joined. For sliced maps, keep Python running: a loopback-only viewer sends only the selected slice, caches prepared frames with a 48-entry/64-MiB limit, and prepares neighboring slices in the background. Slider requests are coalesced after a brief pause, and obsolete responses are not displayed. Filtering and band construction run outside the GUI thread. Revisits are faster while cached; the first uncached slice and browser rendering can still take time. Replot after changing detector geometry to create a fresh view and cache. Closing the GUI or Close All Plots shuts down the local viewers. Changing renderer does not repeat the simulation or modify saved numerical results.

Legacy energy/rotation mappings use an optimized path: geometry is evaluated once per sampled rotation, and bandwidth intervals identify the accepted sampled energies. Boundary candidates are rechecked with the original Bragg formula. Parallel execution uses bounded shared-memory orientation batches, avoiding thousands of process tasks and repeated process startup per slice. Rotation/rotation and motor-chain scans retain their existing execution paths. The log names each distinct slice and reports its selected extra-parameter values. Progress restarts for each slice; this is not a duplicate submission. Fine grids can still produce large results: memory, saving, detector filtering, and plotting costs grow with the number of accepted reflection points.

Scripts can pass extra_scan_ranges={'rotz': (-20, 20, 10)} to scan_two_parameters_for_Bragg_condition, or named sample motors to scan_two_motors_for_Bragg_condition. Without this argument the return value is the original hkl-to-points dictionary. With it, the return value is a structured mapping-slice dataset suitable for SimulationResult('parameter_mapping', data, {}), save_result, and plot_result.

Reciprocal Space and Ewald Construction

Scan configurations is optional and disabled by default. Enable it under simulate_reciprocal, add parameter rows, and enter start, stop, and step. Legacy geometry supports energy (eV), sam_rotx/y/z, and det_rotx/y/z (degrees). Motor-chain geometry offers sample:<motor> and detector:<motor> instead of legacy Euler rotations. Both offer e_bandwidth, displayed as ΔE/E [% full width]: 2 means a full 2% bandwidth (±1% about the central energy). Values must be at least zero and less than 200. Unscanned parameters retain their current values. Each slider selects a sampled value, not an interpolated configuration; the stop is included only when reached by the step, never overshot.

The compact scan stores one reflection set, the sampled axes, and the geometry. The selected configuration and nearby slider positions are evaluated; the Cartesian product is not computed or stored. For example, 8001 energies and 91 angles provide 728091 selectable configurations without allocating that many frames. The old 2000 configuration limit is removed. Up to eight axes are supported, each with at most one million samples. Browser indexing uses exact integers even for very large combinations. Older dense HDF5 scans remain readable.

Parallel processing and Workers are available for reciprocal scans. The viewer prepares up to two neighboring samples in each direction per axis, using shared-memory worker threads. With parallel processing enabled, up to four background workers are used, limited to Workers minus one (minimum one), leaving capacity for the selected configuration. Without it, one background worker prepares neighbors sequentially. Individual transforms use vectorized NumPy without nested worker pools. Existing full-grid mapping workflows retain their process pools. Parallel settings persist in GUI states and can be changed when replotting. No parallel setting triggers enumeration of all configurations.

Both renderers provide independent sliders, previous/next buttons, and editable numeric value boxes. Typed values snap to the nearest sampled point; values outside the saved range are rejected. Buttons move one sampled position and stop at the endpoints. Newly added parameter rows have blank ranges and use a compact dropdown editor instead of an oversized embedded widget. Plot titles include energy, wavelength, full bandwidth, sample pose, and available detector pose.

Plotly scan views now use a small loopback-only local viewer, with an unguessable session URL. No external service is contacted; Plotly.js is bundled. Each viewer keeps a cache bounded to 48 entries and 64 MiB of numerical data or serialized frames (whichever limit is reached first). Selecting a new position cancels queued obsolete preparation; the selected calculation is not queued behind background work. Nearby and revisited positions become faster as the cache fills, but plot rendering still takes time. Cached frames are temporary, not added to the saved HDF5 file. Keep the Python application running while using the browser sliders. An optional HTML export is a link to that live session, not an independent offline animation. For portable storage, save the HDF5 result and reopen it for plotting later. Close All Plots or closing the simulation GUI stops local viewers; browser tabs are not forcibly closed. At most eight live viewers are retained. Single-configuration Plotly views still use self-contained offline HTML. Matplotlib views have sliders, value boxes, and clickable legend entries. Save/load retains all reflections, including those outside Bragg condition. Changing the renderer does not rerun reflection enumeration. The current detector can be applied during replotting: saved detector scans retain their relative transforms, applied to the newly declared base pose. This moves the detector trajectory as a whole; it does not redefine the saved motor chain or sampled angles. With no detector override, scripts use the saved detector. GUI states store the scan checkbox and table, not numerical frames; older states keep single-configuration mode.

Require detector hit highlights detected Bragg reflections in green; other Bragg reflections remain red. The hkl-list colors match the points. This is a display calculation, not a destructive filter of the saved reciprocal lattice. It uses central-energy rays and rectangular detector bounds, not pixel masks.

Stop safely in simulation task windows requests cooperative cancellation. Scans check between points/solver seeds, cancel queued process work, and wait for active workers to exit. Incomplete simulation results are discarded; the previous completed result remains available. A currently executing numerical solver or native-library call may need to finish before stopping. No GUI thread or worker process is forcibly terminated. Reciprocal-space scan controls appear only for simulate_reciprocal; the 3D detector view has its own optional slider controls. Reciprocal-space results have their own section title. Successful task windows close automatically. Errors and cancellations remain visible. The progress bar shows measured tqdm progress when available, and a busy indicator for lattice preparation or rendering with no known total. The reciprocal explorer can prepare much faster than a two-parameter mapping: the latter evaluates every grid point, whereas the explorer evaluates selected states on demand. These timings are not equivalent computation workloads.

Single-Crystal Detector Sliders

In Single Crystal, select Detector 2D Simulation or Laboratory 3D Simulation and enable Scan configurations under the corresponding simulation sliders. Each view keeps its own saved ranges. Add one or more parameters and enter their start, stop, and step magnitude. A descending range (for example, −5 to −25) also uses a positive step magnitude. The plot gets a slider, previous/next buttons, and editable value box for each parameter. Buttons follow the sampled sequence, including descending ranges, and stop at its endpoints. Legacy mode offers energy, full bandwidth, and sample and detector Euler rotations. Geometry mode offers the active sample and detector motors instead of Euler rotations. Each selected position recalculates the Bragg rays and detector view; typed values snap to the nearest sampled position. The ordinary view is unchanged when scanning is disabled. Scripts can pass scan_ranges={'sam_roty': (0, 20, 1)} to simulate_2d or simulate_3d, or use keys such as sample:omega with the geometry-aware variants.

Rotation order beside the legacy sample Euler angles sets the order used by the 2D, 3D, and reciprocal simulations, with or without sliders. It defaults to xyz for existing sessions. Geometry motor chains use their declared chain order.

In Single Crystal, select Ewald Construction Simulation. The view uses the current lattice, initial crystal orientation, sample rotations (or motor-chain angles), beam energy, bandwidth, and qmax; no detector configuration is required. The reciprocal origin is excluded from the reflection list. Q coordinates are in inverse angstrom, with the incident beam along +x. Each Ewald sphere has radius 2*pi/lambda and centre (-2*pi/lambda, 0, 0), so it passes through Q=0. The bandwidth is the full energy width in percent, consistent with the other single-crystal simulations.

Plotly (browser) is the default renderer. It groups reflections into two interactive point sets (inside/outside the Bragg condition), with hkl and Q in the hover information. Hovering over a reflection in either renderer shows its hkl, Q components, |Q|, azimuth, and elevation. Lab azimuth is 0° along +Qz (up), −90° toward +Qy (left), and +90° toward −Qy (right) in the unrotated detector view. Elevation is measured above the Qx–Qy plane toward +Qz. Angles are in degrees and are undefined where the corresponding direction cannot be determined. A scrollable Bragg hkl list below the right-hand legend lists every distinct reflection currently in Bragg condition, without adding one 3D trace per reflection. Matplotlib includes the hkl entries in its right-hand legend, using additional columns for long lists. The central-energy sphere and optional bandwidth boundaries can be toggled using the legend. For single configurations, the generated HTML includes its JavaScript and works offline, without a server or uploading data. Its local path is printed in the log. The browser handles rotation and zoom independently of the simulation GUI; Close All Plots does not close browser tabs. Matplotlib remains available as an alternative renderer. The 2D and 3D single-crystal detector views show the same Q and angular details when you hover over a Bragg spot, including when intensity coloring is enabled.

Save Results... stores the numerical reciprocal-space result in HDF5; Load Results... followed by Plot Loaded / Last Results redraws it with the currently selected renderer and visibility options, without recalculating the lattice. The saved result retains its original physical conditions. GUI states store the new display options; older GUI states use their defaults. Plotly is included in the gui extra. Existing installations without it can install plotly>=5.18 or use Matplotlib.

For scripts, the existing four positional arguments remain supported:

from trxrdpy.simulation import plot

fig = plot.plot_reciprocal(
    Q_hkls, hkls, wavelength_m, 1.5,
    backend="plotly", html_path="reciprocal.html", show=False,
)

Q_hkls and hkls must be matching N-by-3 arrays; wavelength is in metres. Alternatively, single_crystal.simulate_reciprocal(...) builds the reflection set from sample parameters before plotting.

Analysis GUI

python3 -m trxrdpy.analysis.gui.main_window

Import

import trxrdpy

from trxrdpy import simulation
from trxrdpy import analysis

Common simulation imports:

from trxrdpy.simulation import polycrystalline
from trxrdpy.simulation import single_crystal
from trxrdpy.simulation import cif

Common analysis imports:

from trxrdpy.analysis import calibration
from trxrdpy.analysis import fitting
from trxrdpy.analysis import differential_analysis

from trxrdpy.analysis.MaxIV_FemtoMAX import azimint as femtomax_azimint
from trxrdpy.analysis.Spring8_SACLA import azimint as sacla_azimint
from trxrdpy.analysis.Spring8_SACLA import datared as sacla_datared
from trxrdpy.analysis.ESRF_ID09 import azimint as id09_azimint

The package currently exposes the following top-level modules through trxrdpy.__init__:

from .simulation import utils
from .simulation import experiment
from .simulation import plot
from .simulation import sample
from .simulation import cif
from . import simulation
from . import analysis

Package structure

XRDpy/
├── pyproject.toml
├── README.md
├── LICENSE
└── src/
    └── trxrdpy/
        ├── __init__.py
        │
        ├── simulation/
        │   ├── __init__.py
        │   ├── utils.py
        │   ├── geometry.py
        │   ├── diffractometers.py
        │   ├── detector.py
        │   ├── poni.py
        │   ├── experiment.py
        │   ├── plot.py
        │   ├── sample.py
        │   ├── cif.py
        │   ├── polycrystalline.py
        │   ├── single_crystal.py
        │   └── gui/
        │       ├── __init__.py
        │       ├── main_window.py
        │       ├── state.py
        │       ├── style.py
        │       ├── services/
        │       │   ├── __init__.py
        │       │   ├── path_service.py
        │       │   └── simulation_service.py
        │       ├── tabs/
        │       │   ├── __init__.py
        │       │   ├── polycrystalline_tab.py
        │       │   └── single_crystal_tab.py
        │       └── widgets/
        │           ├── __init__.py
        │           ├── geometry_panel.py
        │           ├── matrix_rotation_window.py
        │           └── path_widgets.py
        │
        └── analysis/
            ├── __init__.py
            ├── common/
            │   ├── __init__.py
            │   ├── paths.py
            │   ├── plot_utils.py
            │   ├── general_utils.py
            │   ├── azimint_utils.py
            │   ├── differential_analysis_utils.py
            │   ├── fitting_utils.py
            │   └── calibration_utils.py
            ├── _shared_2d/
            │   ├── __init__.py
            │   └── azimint.py
            ├── ESRF_ID09/
            │   ├── __init__.py
            │   ├── datared.py
            │   └── azimint.py
            ├── MaxIV_FemtoMAX/
            │   ├── __init__.py
            │   ├── datared_utils.py
            │   ├── datared.py
            │   ├── azimint.py
            │   ├── single_shot_azimint.py
            │   └── ping_references_default.csv
            ├── Spring8_SACLA/
            │   ├── __init__.py
            │   ├── datared.py
            │   ├── azimint.py
            │   ├── single_shot_azimint.py
            │   └── pbs/
            │       ├── parallel_job_sender.sh
            │       └── single_shot_1d_job_sender.sh
            ├── differential_analysis.py
            ├── fitting.py
            ├── calibration.py
            └── gui/
                ├── __init__.py
                ├── main_window.py
                ├── runtime_guard.py
                ├── defaults.py
                ├── state.py
                ├── style.py
                ├── utils.py
                ├── services/
                │   ├── __init__.py
                │   ├── calibration_service.py
                │   ├── differential_service.py
                │   ├── facility_service.py
                │   ├── fitting_service.py
                │   ├── integration_service.py
                │   ├── path_service.py
                │   └── preparation_service.py
                ├── tabs/
                │   ├── __init__.py
                │   ├── calibration_tab.py
                │   ├── differential_tab.py
                │   ├── fitting_tab.py
                │   ├── pattern_creation_tab.py
                │   ├── preparation_tab.py
                │   ├── session_tab.py
                │   └── viewer_tab.py
                └── widgets/
                    ├── __init__.py
                    ├── experiment_widgets.py
                    ├── facility_widgets.py
                    ├── log_widget.py
                    ├── multi_experiment_widgets.py
                    ├── parameter_widgets.py
                    ├── path_widgets.py
                    ├── polarization_widget.py
                    └── task_output_dialog.py

Analysis organization

The analysis section is organized into shared utilities, facility-specific workflows, user-facing analysis APIs, and a modular GUI.

analysis.common

Facility-independent shared utilities:

  • path handling
  • plotting helpers
  • general helper functions
  • common azimuthal-integration helpers
  • fitting utilities
  • differential-analysis utilities
  • calibration utilities

analysis._shared_2d

Shared representative-2D-image azimuthal-integration workflow.

This layer is currently used by:

  • Max IV FemtoMAX
  • SPring-8 SACLA

It is one of the two final-pattern sources supported by those facilities. Their facility namespaces also expose single-shot 1D production and aggregation.

analysis.ESRF_ID09

ID09-specific data-reduction and azimuthal-integration workflow.

At ESRF ID09, the route to generate xy files differs from the homogenized 2D-image workflow used elsewhere. The beamline-provided tools and data structure are handled through a dedicated facility-specific implementation.

analysis.MaxIV_FemtoMAX

FemtoMAX-specific analysis entry points.

This section contains:

  • beamline-specific data reduction
  • metadata handling
  • representative 2D image creation
  • metadata-selected single-shot 1D production
  • final-pattern integration from representative images or single-shot caches
  • wrappers that preserve the facility-facing public API

analysis.Spring8_SACLA

SACLA-specific analysis entry points.

This section contains:

  • beamline-specific data reduction
  • representative 2D image creation
  • run/tag-based single-shot 1D production
  • final-pattern integration from representative images or single-shot caches
  • PBS job-submission helpers for representative-image and single-shot HPC workflows

User-facing analysis APIs

These modules provide the user-facing analysis layer after xy files are available:

  • analysis.calibration
  • analysis.fitting
  • analysis.differential_analysis

The calibration API also exposes plot_detector_and_cake(...), which loads a homogenized dark detector image, performs pyFAI integrate2d integration, and plots the detector image and q/azimuth cake side by side. Detector axes can be flipped independently, and applying the detector mask is optional.

Calibration always uses a representative 2D detector image. Once final xy files are created by either supported source, visualization, fitting, and differential analysis are shared across facilities.


GUI organization

Simulation GUI

The simulation GUI is organized as:

trxrdpy.simulation.gui
├── main_window.py
├── state.py
├── style.py
├── services/
├── tabs/
└── widgets/

It provides GUI access to simulation workflows while keeping the simulation logic in the simulation backend modules.

Current GUI-level features include:

  • polycrystalline simulation tab
  • single-crystal simulation tab
  • matrix-rotation helper window
  • session persistence
  • autosave / restore
  • summary / log section
  • plot-window cleanup

The first Session tab contains saving/loading, a GUI-state JSON drop field, notes, and the configuration summary, followed by Polycrystalline and Single Crystal. A fourth Extra Functions tab contains Matrix Rotation, Equivalent Reflections, q / d / Angle Conversion, pyFAI / Fit2D, and Photon Attenuation Length. Only Close All Plots remains at the bottom right. Both simulation tabs accept CIF file drops. Sections can be collapsed without changing their values or enabled settings; collapsed sections and utility inputs are included in GUI states. Older saved states remain loadable.

Equivalent Reflections uses the current sample's space group and the existing lattice symmetry method. It accepts one HKL or several, such as [(1, 0, 0), (2, 0, 0)], with results grouped by input reflection in an expandable output area. q / d / Angle Conversion converts between q, d, theta, and 2theta using an energy or wavelength, and identifies inaccessible Bragg angles. pyFAI / Fit2D accepts a PONI file or manual geometry values and converts in either direction using pyFAI. Units are shown beside every field. Fit2D cannot preserve independent pyFAI rot3; conversion back returns the canonical orientation. This utility does not modify simulation parameters automatically.

Save PONI... is at the end of Common Detector Parameters in both simulation tabs. It uses the current detector dimensions, edited pixel sizes, binning, geometry, and beam energy without asking for them again. Predefined detectors populate visible pixel counts and editable pixel sizes; simulations use these as an explicit flat-detector template. The export converts the actual detector transform to pyFAI coordinates, including motor-chain translations. Overwriting requires confirmation. Detector-specific distortion maps and masks are not represented by this flat-detector export. All input edits survive GUI state save/load; older states recover their predefined detector's original sizes.

Scan Computation and Results in the single-crystal tab provides opt-in Parallel processing, a worker count, Save Results..., Load Results..., and Plot Loaded / Last Results. It covers fixed-energy HKL targeting, detector collection scans, and two-parameter Bragg scans. No result file is written automatically. HDF5 files store numeric results plus the input GUI state; loading them does not change current controls or rerun a simulation. Targeting plots use the detector/2D/3D plot checkboxes. Result files do not contain pickles.

Parallel scans use ordered independent rows and separate processes (four by default when enabled). Legacy Euler targeting also supports parallel execution; motor-chain inverse targeting deliberately retains serial continuation seeds to preserve solution-branch continuity. Small scans can be faster serially. For scripts, the high-level search functions accept parallel=True, workers=4; use the usual if __name__ == "__main__": guard when starting processes. Parallel controls, but not large computed results, are stored in GUI states. Simulation runs in both tabs use non-modal background tasks, including powder reflection preparation. Each run snapshots its inputs; editing fields or loading a GUI state does not change an active computation. The active tab's Run button is disabled until completion, while other tabs and tools remain available. Figures are created on the GUI thread, not in computation workers. Progress and errors appear in the task window and terminal. Closing the main application is deferred while a simulation is running.

Mapping display offers Points (the default), Band outlines, and Filled bands, for newly computed and saved two-parameter maps. Band modes trace occupied cells on the original scan grid, retaining gaps, holes, and separate branches; they do not connect across angular wraparound. Outlines show the boundary of the accepted band, not a fitted central curve. Boundary precision is limited by the scan steps. Numerical results are never reduced or modified. Grid steps and the selected mode are saved in result metadata and GUI states. Older result files recover scan steps from their stored GUI snapshot where available; otherwise use Points. Band rendering uses sparse occupied-cell runs, not a full rectangular grid: large maps retain their original scan resolution without the previous eight-million-cell display limit. Filled bands merge adjacent rectangles; outlines contain only exposed boundaries, including holes. Mapping legends sit to the right of a square plotting area, automatically using multiple columns to fit the available height. The initial figure widens to make room for the legend; resizing keeps the plotting area square and reflows the legend. Clicking a legend entry still toggles its reflection. The GUI always computes and saves the complete Bragg-condition mapping. The Require detector hit checkbox under Scan Computation and Results is a non-destructive plotting filter for both new and loaded mappings. Change the detector pose and click Plot Loaded / Last Results to view another detector acceptance without repeating the scan; turn it off to view all saved points. The original sample orientation and scan energy are retained, while the detector uses its current Euler or motor-chain pose. The option is disabled by default and saved in GUI states. Ray preparation runs in the background and is cached for subsequent detector poses. Package callers can use plot_result(result, require_detector_hit=True, detector_obj=det). Older unfiltered files recover their sample context from the saved GUI snapshot. Files previously saved with points discarded by the computation-time filter cannot recover those missing points; a warning identifies these partial maps. The low-level scan functions retain their explicit computation-time filter for API compatibility, but the GUI does not use it. Like the existing 2D/3D simulation, the filter uses the central-energy ray and rectangular detector bounds; it does not model dead pixels or module gaps. 2D, 3D, and reciprocal titles show entered Euler angles with their application order. Geometry views show the diffractometer convention and active motor values; any equivalent Euler angles are labelled as fixed laboratory-axis xyz relative to the initial sample orientation. Detector motor conversions use the same explicit xyz label. Titles use the configured precision where available.

Both single-crystal and powder 2D and 3D detector views show a red cross at the direct-beam intersection when the forward beam hits the detector, including tilted and translated detector geometries.

Polycrystalline simulate_2d and simulate_3d project powder cones through the full detector transform, subdivide ring curves according to their detector- pixel curvature, and clip them to the detector edges. The 3D view draws smooth cone surfaces, their detector-intersection curves, and a light display mesh on the detector face. Neither mode needs a cone point count or allocates a full detector pixel grid.

The 2D and 3D powder and single-crystal views also offer Consider intensities. Supply a CIF containing atom sites, then select a colormap (viridis by default) and optional minimum and maximum color limits. Reflections use relative structure-factor intensity |F(hkl)|²; powder rings also use the 1D Lorentz factor. Single-crystal strengths use the maximum theoretical |F(hkl)|² among all allowed reflections as their reference, including those currently outside the Bragg condition or detector. Beam polarization can be switched off or set with a factor from −1 (vertical linear) through 0 (unpolarized) to +1 (horizontal linear). The default is +1 for horizontally polarized synchrotron light. Intermediate values describe partial polarization; an axis-offset field rotates the polarization reference in degrees. The powder correction varies around each ring according to the laboratory scattering direction. The intensity views show a colorbar and label powder rings or single-crystal Bragg spots with their HKL indices. Exact zero-intensity pixels are black. Optional Gaussian noise uses a standard deviation relative to the strongest reflection; optional Poisson background uses a mean relative to that reflection. These display settings are saved in GUI sessions. The 2D powder display draws smooth ring curves over a black detector; optional noise is shown on the detector pixels. The returned experiment exposes reflection_intensities and detector_intensity_image. In 3D, random noise appears only on the detector plane, which uses a compact display mesh. Single-crystal 3D intensity views include a clickable HKL legend with the relative intensity of each reflection. The colorized mode above remains the lightweight default.

Polycrystalline simulate_1d can optionally use the same detector settings. Enable Use detector coverage in the 1D options to derive the reachable q limit from the detector position, size, rotation, and beam energy. The manual qmax field is used only when detector coverage is off. A blank azimuth range selects all 360°. To select a sector, enter (-15, 15) or -15,15 in degrees; the lab-frame convention is 0° vertically up, -90° left, and +90° right when looking along the beam toward the detector. The azimuth offset shifts this reference without following detector rotation. Detector coverage determines which peaks are visible; missing pixels do not dilute their intensities in the azimuthal average. The Python API accepts a Detector via simulate_1d(..., detector=detector) and returns detector_qmax and coverage_fraction alongside the pattern. Coverage uses the central beam energy and rectangular detector bounds; beam bandwidth, pixel masks, and module gaps are not included. Detector settings entered on either simulation tab carry over when switching between Polycrystalline and Single Crystal.

The single-crystal 3D view uses the same lightweight detector face and visual mesh. A colored dot marks each forward Bragg ray that falls within the detector pixel bounds; rays that miss the detector have no hit dot.

Detector Euler angles retain their named axes for every rotation order, keeping the 3D detector grid, Bragg positions, and direct-beam marker consistent. Custom sample orientation matrices and the Matrix Rotation tool's mode, Euler rotation order (default xyz), angles, and result survive GUI-state save/load without requiring another import.

Analysis GUI

The analysis GUI is organized as:

trxrdpy.analysis.gui
├── main_window.py
├── defaults.py
├── state.py
├── style.py
├── utils.py
├── services/
├── tabs/
└── widgets/

The Analysis GUI supports:

  • session persistence
  • autosave / restore
  • facility selection
  • Data Reduction for metadata, representative 2D images, and supported single-shot 1D caches
  • calibration utilities
  • detector-image and 2D-cake visualization
  • Azimuthal Integration from representative 2D images or completed single-shot patterns
  • 1D visualization
  • differential analysis
  • peak fitting
  • task-output dialogs for long-running operations
  • shared single-experiment metadata across tabs
  • log output
  • plot-window cleanup

The GUI layer is intentionally separated from the computational backend so that workflows can also be used programmatically.

When the 1D Viewer regenerates XY patterns, its q-point count follows Number of q points in Azimuthal Integration rather than a separate viewer default. ID09 synthetic fluence scans copy previously integrated delay curves and retain their source q grid.

Fitted-property display modes

In Fitting Analysis, leave both display-mode boxes unchecked for absolute values. Normalize (0-1) maps the selected reference to zero and the maximum to one; Relative variation (%) displays 100 * (P - P_ref) / P_ref. These options are mutually exclusive. Reference lines and baseline error bars use the same transformation, and normalized axes omit physical units. The reference estimate is treated as fixed when scaling the existing baseline spread; these are not newly calculated fit-parameter confidence intervals. Zero denominators and unavailable references produce an error.

Single experiments use the reference controls in their series selection; multiple experiments use each entry's reference. Merged delay entries retain their existing pooled negative-delay baseline. References must exist in the fitting CSV; changing the plot reference does not refit or rewrite that CSV.

Multiple fitting experiments can optionally specify an Azimuthal selection per entry: Full, a center such as 30 for phi-averaged fits, or a sector such as (-15, 15) for separate-phi fits. Blank fields retain the shared selection. The corresponding API descriptor key is phi_window.

Multiple-fluence plots have an optional Colormap field. Leaving it blank keeps the previous default colors (cmap=None); entering, for example, viridis uses that Matplotlib colormap. All new controls and per-experiment selections are included in saved GUI states, and older states remain loadable.


Facility-specific workflow overview

The analysis pipeline is intentionally split because raw-data handling differs across facilities.

Max IV FemtoMAX

Repeated scan numbers are processed only once, preserving their first-occurrence order. For fluence scans, supply fluences aligned with either the original list or the unique scans; repeated entries for a scan must agree on its fluence.

When ping timing is unreliable, scan_delay_overrides_fs={scan: delay_fs} optionally assigns an exact delay to every detector shot of selected scans. Unlisted scans retain normal ping timing; the default is None. The Analysis GUI exposes Scan delay overrides and an Override delay unit in FemtoMAX Data Reduction. Both paths write the same downstream metadata structure. Changed assignments require metadata and derived-product regeneration; dark scans ignore overrides. For fluence scans, assignments must match the selected fixed delay. Use a fresh analysis subdirectory when reassignment would leave obsolete products under old delay names.

  • Uses facility-specific data reduction
  • Always creates or locates a representative 2D image for calibration
  • Can produce final xy files from homogenized 2D images
  • Can instead integrate metadata-selected frames into a resumable single-shot 1D cache
  • Can refresh the same final xy filenames while that cache is still growing
  • Then uses the shared downstream analysis pipeline

SPring-8 SACLA

  • Uses facility-specific data reduction
  • Some reduction steps may depend on beamline-specific software, legacy Python environments, VPN access, or HPC job submission
  • Always creates or locates a representative 2D image for calibration
  • Can produce final xy files from homogenized 2D images
  • Can instead integrate metadata-selected run/tag pairs into a resumable single-shot 1D cache
  • Retains the SACLA chunked/PBS execution model for large single-shot productions
  • Then uses the shared downstream analysis pipeline

ESRF ID09

  • Does not use the same 2D homogenization route as FemtoMAX/SACLA
  • Uses a different beamline-specific azimuthal-integration workflow to generate xy files
  • Does not provide the single-shot 1D production mode
  • Then uses the same downstream fitting and differential-analysis pipeline

In other words:

  • data reduction differs across facilities
  • FemtoMAX and SACLA support representative-2D and single-shot-1D sources
  • ID09 retains its dedicated image-based xy generation workflow
  • the downstream analysis after xy creation is shared

Notes

  • Some analysis workflows may require facility-specific dependencies that are not part of a standard Python installation.
  • Some SACLA workflows may rely on legacy Python environments and external HPC job submission.
  • The simulation and analysis sections are developed within the same package but target different use cases.
  • The project is published on PyPI as trxrdpy because the xrdpy name is already taken on PyPI.

Citation

If you use XRDpy in academic work, please cite the Zenodo record corresponding to the version you used.

Version-specific citation metadata is available on the Zenodo release page.


License

Creative Commons Attribution 4.0 International (CC BY 4.0).

See LICENSE for details.


Authors and Collaborators

Julio Guzman-Brambila, D. Léa, M. Lorenc, E. Janod, C. Mariette.

The ordered author list is also recorded in CITATION.cff, .zenodo.json, and the PyPI package metadata. See CITATION.cff for a machine-readable citation.

Optional PONI detector calibration files

The simulation module can optionally read detector calibration values from a PONI file. This provides an additional detector-geometry input route while preserving the existing manual detector parameters.

The PONI reader is implemented in:

src/trxrdpy/simulation/poni.py

The reader parses detector distance, PONI coordinates, pixel sizes, detector shape, rotations, wavelength, and detector metadata when available. The Detector class can use the parsed distance, PONI coordinates, pixel sizes, detector shape, and rotations directly. PONI rotations are stored in radians in the file and converted to degrees before being passed to the Detector.

Manual detector input remains available and does not require a PONI file. A PONI file is used only when a path is explicitly provided or when the detector type is set to poni.

Example:

from trxrdpy.simulation.detector import Detector

det = Detector(
    detector_type="poni",
    poni_file="calibration.poni",
)

The graphical interface also exposes an optional PONI file field in the polycrystalline and single-crystal simulation tabs. If no PONI file is selected, the usual manual or predefined detector configuration is used.

The detector rotation order is shown explicitly in the GUI and can be changed. Available orders are zyx, zxy, yzx, yxz, xzy, and xyz. The default detector rotation order is zyx.

Offline photon attenuation length

The simulation GUI's Extra Functions → Photon Attenuation Length opens a standalone scan. Enter a chemical formula directly or load it from a CIF, then supply its density in g/cm³. Grazing-incidence depth is the default; bulk length is also available. Energy controls use eV and a step size. The optional incidence-angle scan evaluates the visible curve on demand. Choose the slider motor before plotting: Incidence angle shows depth versus photon energy, while Photon energy shows depth versus incidence angle. A numeric box beside the slider selects an exact value, including positions between scan steps. Previous/next buttons jump to adjacent sampled values while numeric entry continues to accept values between them. The window shows numerical points and saves the selected plot to PDF. Data export defaults to compressed HDF5 (.h5), with CSV available for readable exchange. Both formats store length values in meters and material metadata once per file; the display unit stays in the window. HDF5 files load lazily, so only the viewed curve enters memory. When plotting loaded data, angles between saved steps use linear interpolation between the two adjacent saved curves. Photon energies between saved steps are handled similarly. The simulation GUI state saves the window's inputs and plot preferences, not calculated curves. CIF density is not assumed; check and enter the measured density. All 92 CXRO elements are available offline.

import numpy as np
from trxrdpy.simulation.attenuation import XRayMaterial
from trxrdpy.simulation.attenuation_plot import AttenuationData, plot_attenuation

energy_eV = np.arange(10000, 15001, 10)
material = XRayMaterial("SrTiO3", 5.12)
depth_m = material.grazing_penetration_depth(energy_eV / 1000, 1.0, unit="m")
data = AttenuationData(energy_eV, depth_m, [1.0], "grazing", "µm", "SrTiO3", 5.12)
plot_attenuation(data)

The optical index is n = 1 - δ + iβ. Bulk intensity attenuation length is λ/(4πβ). Normal grazing depth is 1/(2 Im kz), with kz = (2π/λ) sqrt(sin²α - 2δ + 2iβ) and angle α measured from the surface. Negative beamline rotY values can be converted to the physical angle with abs(rotY) before calling the API, or through grazing_depth_from_rot_y. The numerical API accepts keV while GUI, plots, and CSV use eV. The exact=True option uses sqrt(n² - cos²α) instead. These are homogeneous, semi-infinite optical models; they do not include roughness, standing waves, diffraction sampling, or finite films. See the local data notes for provenance, interpolation, and adding elements.

Metadata

Release files for trxrdpy 5.1.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for trxrdpy 5.1.0
File Size Uploaded Provenance Actions
trxrdpy-5.1.0.tar.gz 17.4 MB With provenance Details for trxrdpy-5.1.0.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for trxrdpy 5.1.0
File Interpreter ABI Platform Actions
trxrdpy-5.1.0-py3-none-any.whl Python 3 none any Details for trxrdpy-5.1.0-py3-none-any.whl

Total release size: 34.9 MB

Release files / trxrdpy-5.1.0.tar.gz

Download URL trxrdpy-5.1.0.tar.gz
Size 17.4 MB
Tags Source
SHA-256 checksum
How to use checksums
f06423e82abab79b7a59d98339082b3b48f0691015baaed54fbfe92fda79b04a
BLAKE2b-256 checksum
How to use checksums
2b9f35163d866184ff240b5ca8423e2ab738be034965aa052315485c35716e74
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 23, 2026.

Transparency log

Release files / trxrdpy-5.1.0-py3-none-any.whl

Download URL trxrdpy-5.1.0-py3-none-any.whl
Size 17.4 MB
Tags Python 3
SHA-256 checksum
How to use checksums
ef3dae4aea8f691cd2ebcd420e6b9a7758229eb845e0b26fa322907e87f7b2f6
BLAKE2b-256 checksum
How to use checksums
d6e83ac00d748c44fde2b9432c85e3d73d0e156c2ea6ce32a2858d350c10e1be
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 23, 2026.

Transparency log

Security for trxrdpy 5.1.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

Both files in this release have been uploaded with provenance metadata.

Select from 2 files

Attestation for trxrdpy-5.1.0.tar.gz

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 23, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page