Skip to main content
Pre-release

This release is a pre-release and may not be stable for production use.

UltraZohm Data Viewer (ultrazohm_dataviewer)

A desktop data viewer (Windows and Linux) for UltraZohm JavaScope logs, built with Dear ImGui via imgui_bundle and ImPlot. It succeeds the Plotly/Dash javascope/dataviewer.py, with a native live-data prototype and a VSCode-style docked layout, drag-and-drop subplots, dedicated FFT/Histogram analysis windows, range-aware downsampling for multi-gigabyte logs, and a Python and terminal control API for automating data, analysis and plot settings.

+------------------------------------------------------------------+
|  Navigation  |      Plots / FFT / Histogram  (docked tabs)         |
|  runs &      |   Plots: runtime grid of subplots (1x1 ... 5x5)    |
|  signals     |   FFT / Histogram: dedicated analysis windows     |
|--------------|                                                   |
| Log Browser  |                                                   |
| / Console    |                                                   |
+------------------------------------------------------------------+

Log Browser and Console share the lower-left dock; Log Browser is selected at startup. On Windows and Linux sessions identified as X11 (XDG_SESSION_TYPE=x11), drag a panel's tab outside the main window to detach it into a desktop window. Drag it back to redock. Other environments keep panels inside the main window. View → New plot window opens an additional empty grid. Its signal assignments, axis ranges, cursors and downsampling settings are independent; recordings and their data cache are shared. Hide and reopen these windows using View. Additional plot windows last for the current session: loading a session closes them, and saved sessions preserve their independent grids. Their actions appear as labelled informational messages in the console.

Features at a glance

  • Load many files — .csv (JavaScope ; or standard ,, auto-detected) and .parquet, read with Apache Arrow. Open via the button or drag files onto the window (desktop).
  • Matlab-style navigation — runs → channels, (de)activate/remove, per-log time normalization.
  • Subplot grid — independent Rows and Columns sliders (1–5), draggable dividers, drag-and-drop signals, types line/scatter/stairs/XY, linked X axes and secondary Y axis. Right-click a plot for Reset view, Clear, cursors, show samples, CSV export and spy (a separate zoom window). Double-left-click a plot or axis to perform Reset view for that subplot. The popup's Grid layout menu also offers the sliders and Equal sizes. Divider sizes are saved with JSON sessions; older sessions start with equal sizes.
  • Range-aware downsampling — a min/max pyramid (pure NumPy) for time series; multi-GB logs pan at full fps and zoom reveals detail. (XY plots decimate by plain stride.)
  • FFT & Histogram windows — overlay several signals, pick the time window (follow a plot / full / custom), compute on demand, log axes, CSV export.
  • Node canvas — drag a signal into a graph, apply transforms (FFT / math / filter / shift), and the result becomes a new draggable signal. Fully scriptable (node_*) and extensible with your own Python plugin nodes (see Plugins).
  • Python automation — control the open viewer with ultrazohm_dataviewer.Client from a terminal, Python file, or the Python panel. The application log reports actions and errors. Sessions save to JSON.
  • MaterialFlat theme. Runs on Windows and Linux.

Quick start

Use uvx ultrazohm-dataviewer on Linux or Windows, or extract the Windows standalone ZIP. For Python scripting and repository development, see the application installation guide.

ultrazohm-dataviewer
ultrazohm-dataviewer gui path/to/log.csv
ultrazohm-dataviewer gui session.json

Start the GUI with ultrazohm-dataviewer, then use ultrazohm-dataviewer status from another activated terminal to control it. ultrazohm-dataviewer --help lists application commands; ./uz --help lists repository tasks. Input paths are relative to your current directory.

On desktop, selecting a CSV larger than 1 GiB prompts Large log, conversion to parquet recommended. Choose Open CSV to read it directly, or Convert to Parquet to create and open a file with the same stem and directory (for example, logs/run.csv becomes logs/run.parquet). This applies to native drag-and-drop, the Log Browser and the file picker. Conversion runs in the background using the selected backend and opens the result with the selected loading mode. The original CSV is preserved; an existing Parquet file is never overwritten and can instead be opened explicitly. Choosing Open CSV skips automatic disk-cache conversion for that load, even when disk caching is enabled. Console/API conversion follows the same safety policy: existing destinations are never overwritten, empty recordings are rejected, and failed or cancelled conversions clean up temporary output.

Then Open file(s)… in the Navigation panel, expand the run, and drag signals into the plots (or the FFT / Histogram windows).

Settings

Click Settings in the menu bar to open a non-modal window:

  • General: log browser directory and startup visibility of Application log and Python.
  • Data loading: backend, loading mode, and disk cache for newly opened recordings.
  • Performance: RAM cache limit and display points per signal.

Edits apply immediately (except startup visibility) and persist as application defaults in viewer_preferences.json in the platform user data directory. Each section has Reset this section. An empty log directory uses the firmware checkout's artifacts directory. The status bar displays FPS and cache usage.

Session files retain their own data and plot settings; loading a session does not rewrite application defaults. Explicit startup options override saved defaults for that launch. Device configuration remains in its acquisition panels. The Python client uses the same settings service:

viewer.get_settings()
viewer.set_setting("cache_budget", 512)
viewer.set_setting("show_application_log", False)

Large recordings and responsiveness

The Data Viewer never uses GUI idle throttling. Idling stays disabled during live streaming, paused views, and offline analysis, even without mouse or keyboard input. Actual FPS still depends on rendering workload and display synchronization.

The desktop defaults to Polars + Lazy; the online version uses PyArrow + In memory. Choose Settings → Data loading → Loading → In memory / Lazy before opening files, or select the mode at startup:

ultrazohm-dataviewer gui --loading-mode lazy path/to/log.parquet
ultrazohm-dataviewer gui --loading-mode lazy path/to/log.csv
  • In memory retains the existing full NumPy arrays for fast analysis.
  • Lazy (desktop default) reads selected columns and sample ranges from Parquet or streams CSV directly. CSV requires repeated text scanning and is slower for interactive navigation.

The setting affects subsequent opens. Existing runs retain their storage mode; JSON sessions preserve mixed modes. The Python client equivalents are viewer.loading_mode("lazy") and viewer.cache_budget(1024).

Plot preparation, first-use summaries, XY sampling, cursor reads, and GUI FFT / histogram computation run outside the desktop rendering thread. During an update, the last completed plot remains visible. Up to four plot requests run concurrently, so a slow first-time summary of one channel does not hold back other subplots; concurrent requests can each hold their own decoded batches in memory. Superseded display requests are cancelled or discarded. Main and spy plots reuse completed results, and finite display-point budgets account for pixel width and trace count. Gap markers may add points beyond the finite-point budget.

Parquet opens use footer statistics when available. The first sample query validates timestamp order and builds a persistent timestamp index; files without usable statistics need that scan during opening. First display of a channel builds its persistent min/max summaries. These operations stream through the file and can take seconds for large recordings. Reopening reuses valid indexes. Changed files must be reopened; cached results from their previous version are not reused, including in XY plots and cursor readouts. Lazy reads run on the desktop worker even for short recordings.

The shared timestamp/summary RAM cache defaults to 1,024 MiB and is configurable with Settings → Performance → RAM cache (MiB). Prepared plot arrays are bounded by display budgets. Cache limits are not a hard process-RAM limit: decoded batches, index-building scratch, FFTs, explicit NumPy conversions, exports and Python transformation plugins can allocate additional memory. A full-recording FFT still needs its raw input and output arrays. Histograms stream raw batches in two passes. Node evaluation runs on a detached graph in a background worker. Results are published on the application thread only if the graph and source inputs still match. Editing inputs during evaluation discards the result; evaluate again to use the new settings. Cancellation takes effect between reads and transforms; a running native transform returns before its cancellation can be observed.

Measurement caches stay in RAM by default; no automatic CSV conversion is written. Enable Settings → Data loading → Disk cache, pass --disk-cache, or use viewer.disk_cache(True) to persist indexes and summaries and convert lazy CSV inputs into reusable Parquet files. Reopen existing files to change their cache policy. JSON sessions preserve the setting for each file. When enabled, disk caches live in ~/.cache/ultrazohm_dataviewer (Polars uses its polars/ subdirectory), or the directory selected by UZ_DATAVIEWER_CACHE. They are disposable and source-versioned; close the viewer before clearing that directory. Disabling disk caching leaves existing cache files untouched and does not read them. There is currently no automatic disk-cache size limit. Read-only or full summary-cache storage falls back to RAM; enabled lazy CSV conversion requires writable cache space.

Session format and analysis correctness

Sessions now use schema version 6 with explicit run identities, including repeated opens and identical filenames in different directories. Node links preserve explicit input slots, including disconnected slots. Canvas connection order does not change subtraction or division. Restoring a saved session replaces the current session only after successful loading. Failed restoration leaves the current session intact. Version 1–5 snapshots and generated session scripts must be recreated as JSON sessions; version 6 records the materialized output domain explicitly. Plot windows, precise time ranges and inactive recordings survive JSON round trips. Restoring a session resets panel caches and canvas positions; Y fitting completes when lazy samples arrive. Both primary and secondary Y limits survive JSON saves, including mouse zoom. Removing a followed subplot switches its analysis windows to Full and discards the removed plot's cached range. Recomputing a node preserves its derived recording's selected time origin. Live snapshots and other runs without a backing file cannot be saved in a session; export their data first. Chain transforms with node links; using derived outputs as new source nodes is no longer supported. Analysis and exports use exact time windows, while plotting retains edge padding. Full analysis covers all selected recordings regardless of selection order. Linked time ranges apply immediately to scripts, exports and analysis, including before the first GUI frame. Reset view updates the linked range to the selected plot's recording extent. FFT inputs must be equal-length one-dimensional arrays. FFT and FIR filters reject duplicate or irregular timestamps. JavaScope logs identified by raw CHn=n) headers use their 10 ns timestamp resolution: samples must fit one uniform grid within ±5 ns plus floating-point roundoff. This also applies after conversion to Parquet and time normalization. Other inputs retain the 100 ppm interval tolerance. For plain-array API calls, pass timestamp_resolution=data.timestamp_resolution from data = uz.read(path) to uz.fft(...) or uz.filter(...); the default is unspecified precision, not an assumed JavaScope format. No samples are resampled. Binary math and XY plots require matching timestamps throughout both inputs; implicit index alignment and XY truncation have been removed. XY limits and zoom survive session round trips without changing linked time axes. Stale or failed derived outputs are blocked from plots, analysis and exports until successful reevaluation; existing assignments are preserved, including across JSON restoration. Failed graphs restore with empty, unavailable output placeholders until repaired. Source validation covers original CSV files even when reading a cached conversion. JSON is the only saved-session format; generated session-script export has been removed. Python automation uses viewer.load_session("session.json"); calls run sequentially and exceptions stop the script unless handled. Completing an export dialog after its subplot was removed cancels the export. FFT export validates every selected signal before writing: an invalid channel fails the export with its name and reason, preserving any existing destination file. The FFT window reports each failed channel even when other channels succeed. Plugin imports roll back their registrations on failure. Existing transform kinds cannot be replaced at runtime; restart the viewer after editing a loaded plugin.

Division and reciprocal transforms preserve undefined samples as NaN gaps; FFTs reject those inputs rather than treating undefined values as zero. Numeric node parameters must be finite, and integer parameters must fit a 32-bit integer. Built-in and plugin parameter editors use the same declared types as validation. Removing a recording immediately invalidates its analysis results. Explicit FFT/histogram X limits survive recomputation; Reset view clears those limits. These explicit analysis view limits also survive JSON session restoration. Shared upstream nodes are validated once per traversal, avoiding exponential work in graphs with reused inputs. Hann windows are released after each FFT. Native CSV materialization uses checked batch allocation for both backends, including actual row counts and retained buffer capacity. Parser scratch and transient growth copies remain outside the numeric-data budget. Both CSV backends share missing-value spellings (including NA, NULL and NaN).

Session restoration rejects malformed coordinates, unknown plot types/styles, and invalid numeric settings before replacing the current session. Commands use the same bounds: 1–100,000 histogram bins, 1–16 rows/columns, 2–1,000,000 display points, and 1–1,048,576 MiB of cache. Mouse zoom in analysis windows persists through recomputation and JSON restoration. FFT display sampling, including summary rebuilds after cache eviction, runs on a desktop worker. Headless reads, conversions, and analysis do not import the GUI. Import GUI entry points explicitly from ultrazohm_dataviewer.app; package-root GUI aliases were removed.

Documentation

Doc For
Usage Driving the app: panels, plots, analysis windows, Python automation, application log, full client API reference.
Architecture Developers: module map, the state-driven/command-routed design, internals, how to extend, testing, design decisions.
Build Tasks, desktop bundles and releases.
Plugins Writing your own node transforms as Python plugins.
Library Using the data/analysis core headlessly as a Python library (load logs, FFT, node transforms) — no GUI.
Roadmap Open ideas and the record of what's already shipped.
Dataviewer V Javascope How the live JavaScope and this offline viewer relate, and the legacy dataviewer.py it succeeds.

Project layout

ultrazohm_dataviewer/
├── run.py                    # run from a source checkout (also accepts Python startup files)
├── src/ultrazohm_dataviewer/
│   ├── app.py                # docking layout, runner, theme, Session menu
│   ├── state.py              # AppState, SubplotCell, FFT/Histogram configs
│   ├── commands.py           # command registry / parser / dispatcher (the script API)
│   ├── console.py            # application activity log
│   ├── model.py              # Run / Signal / DataRegistry (+ time normalization)
│   ├── loader.py             # CSV/Parquet loading + channel-name parsing
│   ├── sources.py            # raw sources, bounded caches and min/max summaries
│   ├── downsample.py         # visible-window selection and display adapter
│   ├── analysis.py           # GUI-free transforms (FFT)
│   ├── transforms.py         # GUI-free node transforms (math, FIR filter)
│   ├── nodes.py              # dataflow graph + evaluation -> derived signals
│   ├── plugins.py            # external transform-node plugins (@transform, loader)
│   ├── session.py            # JSON save/restore + CSV export
│   └── panels/               # navigation, plots, analysis base, fft, histogram, nodes
├── tests/                    # pytest (logic via commands + headless rendering)
├── tasks.py                  # lint and test; Windows bundle and bundle-smoke
└── build/                    # PyInstaller spec and frozen smoke tests

Documentation lives in ../docs/source/guide/gui/ultrazohm_dataviewer/.

Tests

Run the same checks as CI, on Linux (dev container) or Windows:

./uz check viewer                  # ruff and the full pytest suite, with a CLI wheel from this checkout
./uz build viewer                 # PyInstaller bundle in dist/
./uz task viewer bundle-smoke           # its smoke tests

The tasks use ultrazohm_dataviewer/.venv-ci, separate from the shared repository .venv. check builds a debug CLI wheel from ../ultrazohm_cli unless --cli-wheel PATH is given, so the live tests run against the same commit. ./uz check viewer forwards to the same task implementation. Linux CI runs it in the ci stage of .devcontainer/Dockerfile; Linux is distributed through Python wheels. Windows standalone packaging copies the build system's libraries.

The console transcript does not capture every GUI gesture (including analysis Reset view and some Y/XY gestures). Use JSON snapshots for supported view settings. FFT-derived plots use Hz, remain independent of linked time axes, and export a frequency column. Time normalization and time-based analysis reject spectra.

Sampling and domain transitions

Timestamp roundoff allowances are bounded to one percent of a sample interval. FFT and FIR reject axes whose absolute timestamp precision cannot establish that bound; binary math and XY never treat a sample-sized displacement as roundoff. Graph domain resolution shares a per-evaluation cache and uses iterative traversal. When a saved graph changes an output's domain, restoration discards its incompatible normalization and consumer assignments, matching live reevaluation. Failed outputs retain their saved domain as unavailable placeholders until repaired.

Native live-data prototype

Python and terminal automation

The viewer hosts a local control API at 127.0.0.1:19741. Open an environment shell with ./uz shell, then use ordinary Python or terminal commands. Control commands attach to an existing application:

ultrazohm-dataviewer --endpoint 127.0.0.1:19741 gui
# In another terminal:
ultrazohm-dataviewer status
ultrazohm-dataviewer load recording.csv
ultrazohm-dataviewer set-grid 3 2
ultrazohm-dataviewer --json list-runs
from ultrazohm_dataviewer import Client

with Client() as viewer:
    run = viewer.load("recording.csv")
    viewer.set_grid(2, 1)
    viewer.add_signal(1, run, "current")
    view = viewer.create_view()
    viewer.add_signal(1, run, "current", view=view)
    viewer.save_session("analysis.json")

Client uses an explicit endpoint, then UZ_DATAVIEWER_ENDPOINT, then the default. Each viewer instance needs a distinct endpoint. Recording, node, and view handles belong to a session; removal or session replacement invalidates old handles. list_runs(), list_nodes(), list_plots(), and list_views() inspect state. Terminal subcommands use hyphens, Python methods use underscores. Run ultrazohm-dataviewer --help or a subcommand's --help for signatures. --json prints machine-readable results; failures return a nonzero exit code.

Calls execute sequentially for each client. Loads and exports return when ready, while manual GUI interaction remains available. Manual changes can occur between calls; interactive automation is not a deterministic batch transaction. Client paths resolve from the caller's working directory. Mutations are never retried automatically after a transport failure, because they may already have completed.

The Python panel is available in offline and live modes through View → Python. It edits ordinary .py files. Run saves the file and starts a fresh process in the viewer environment, with UZ_DATAVIEWER_ENDPOINT supplied. Managed device run requires a connected acquisition service, supplies UZ_ACQUISITION_ENDPOINT, locks manual device controls, and provides Stop script + device. Ordinary Stop script terminates Python without issuing a hardware Stop. External terminal processes remain externally owned. A script can import both ultrazohm_dataviewer.Client and ultrazohm_cli.Client; the latter connects to the acquisition service.

The Application log displays diagnostics and operation activity. It has no command input. .uzscript and the old uz … console shortcut are removed. Use normal .py files and the acquisition package's terminal interface instead. See compare_recordings.py for the two-recording PT1 comparison workflow.

JSON schema 6 snapshots preserve recording references, node graphs, analysis settings, and additional plot grids. Recording paths are relative to the JSON file where possible. Saves replace files atomically; failed restoration leaves the existing workspace intact. Python variables, processes, and interpreter state are not persisted. Source builds use the project venv; frozen builds run scripts using bundled modules. An external Python environment can also attach to either. Choosing Load state manually stops app-owned scripts and clears pending startup automation before loading. External scripts retain ownership of their processes; their old session handles are rejected after replacement.

Each viewer creates a random local control credential. Python clients and the CLI discover it automatically in a private per-user directory under the OS temporary directory. No token needs to be copied for normal use. Credentials are removed on shutdown; a restarted viewer requires a new client. The listener accepts only loopback connections and does not execute Python code from requests.

Starting acquisition

The ordinary launcher and the bundle include the CLI; no Rust compiler is needed. Startup does not connect to hardware; Connect starts acquisition; Existing service → Attach reuses an existing service. Relative recording arguments keep their original working directory.

Launching ultrazohm-dataviewer from an UltraZohm checkout (or any of its subdirectories) automatically selects that checkout for live mode. gui --live-repo PATH overrides this default. Outside a checkout, use Live Data → Browse for ultrazohm_sw; Browse also lets you switch to another checkout after startup.

Preparing the selected checkout asks the CLI for channel-mapping --repo PATH and, when preferences are missing, profile --repo PATH. The CLI reads current headers and filters only built-in default assignments. Metadata is returned directly; ordinary preparation creates no mapping cache file. Preparation runs in the background, and failures appear in Live Data without closing the viewer. Connect and Flash UZ require successful preparation; attaching to an existing service does not.

Connect launches serve --repo PATH --profile settings.json. The service resolves the firmware configuration itself, strictly validates saved preferences, and exposes the effective configuration through catalog. An existing service keeps its loaded configuration. Shut it down and reconnect to apply a different repository or changed headers. Select the checkout in the viewer, or pass ultrazohm-dataviewer gui --live-repo PATH.

Repository setup selects both applications consistently: stable and prerelease use published packages; local uses the checkout. Use --app viewer to include both. Re-run ./uz setup local --app viewer after CLI changes.

Flash UZ, beside Connect/Disconnect, opens an OK / Cancel confirmation. The button is greyed out when Vitis XSCT is missing from PATH, with a tooltip explaining how to load the Vitis environment and restart the viewer. Availability is also checked again before any device or logging changes. OK sends device Stop, stops active fast and slow logging and waits for completed files, shuts down the service, regenerates the header mapping, and runs the CLI's build/program operation. Progress and tool output appear in the Console while the GUI stays responsive. After success, a fresh acquisition session starts and connects to the device. Logging is idle and system/control remain in the firmware startup state. Cancel makes no changes. If no service is running, programming can start directly. A Python script or active debug CLI jobs disable the flash button; the workflow locks device controls, script execution, and debug CLI submissions.

Managed flashing uses javascope_<commit>.json in the applicable user directory, including -dirty when applicable, and regenerates/replaces that cache on every attempt, like startup. The prototype assumes headers stay unchanged during build/programming, as agreed; no checksum check is performed. The restarted service loads the new JSON, keeps existing channel assignments whose names remain available, and reports removed names. Sampling period, buffer, flush settings, and ACK policy are preserved when restarting an existing service. Existing recordings retain their original data and mapping. Errors stop later steps and appear in the Console; retries retain the captured service settings. If the viewer closes during programming, the CLI finishes independently and the viewer does not start a replacement service afterward.

  • Live Data sits beside Navigation. Connect starts a service at the selected endpoint and connects it to the device. Existing service → Attach attaches to an already running service without changing its device connection. An existing service owns its settings; session directory and channel mapping fields apply only when launching a new service. The session directory must not exist. A sibling <session>.service.log contains service startup diagnostics. Connection progress appears immediately above the controls, followed by a connected/data-reception indicator or an error. Progress and results also appear in the Console; connection buttons stay disabled while a request is pending.
  • The 20 channel slots show the service's requested assignments. Double-click a slot to choose an observable using case-insensitive fuzzy search. Use Up/Down to highlight a result, Enter to assign it, and Esc to cancel. Typing continues filtering the list after arrow navigation; editing the query highlights the first match. Matches accept gaps between characters, but require their original order; contiguous matches rank first. Selection is blocked while either stream is recording. A mapping/reconnect generation change clears live plot assignments and cached samples; drag the desired signals again.
  • Drag channels into Live Plots. This reuses the normal plot renderer, grid, zooming and display downsampling, with independent live axes and drag targets. Follow live anchors the right edge at the newest sample. Mouse-wheel zoom changes X and Y like the ordinary Plots window; X zoom updates Time depth (s). Live Plots uses exactly the ordinary Plots window's ImPlot mouse mapping, including its pan/box-selection buttons and modifier-based axis constraints; it does not remap buttons. Ordinary wheel and box zoom keep following: their X span becomes the time depth and the right edge returns to the newest samples. Shift-modified zoom enters Inspect and keeps the selected region, freezing the current bounded RAM snapshot while acquisition and logging continue. Horizontal panning also enters Inspect. Unchecking Follow live freezes the display in the same way. The slider controls the same X duration. In Inspect, normal cursor-centered zoom and pan work; the slider changes duration around the current view's center. Checking Follow live catches up to the newest samples at the chosen duration. Reset view, including a double-left-click on a plot or axis, also resumes Follow live and resets the subplot's axes while preserving the chosen time depth. The toolbar's Reset view resets all subplots; the popup and double-click reset the selected subplot. No disk/cloud history is fetched in either mode.
  • Freeze plot 1 for analysis copies all channels in that plot's time window to Navigation and assigns its plotted signals to the normal Plots window. FFT, histogram and nodes can then consume stable samples. Snapshots are memory-only; export them if needed before closing the viewer.
  • Control exposes Enable System, Enable Control, device Stop, user buttons 1–8, and a scrollable variable table populated from the service's JSON mapping. Each row retains its own entered value; press Enter in that input to send it. A successful send highlights that value blue for 0.2 seconds. Editing, leaving a field, and filtering do not send commands. The filter narrows the table; rows follow command-ID order. Entered values are local, not device readbacks, and inputs are disabled while a Python script runs. Commands are sent without firmware acknowledgment; streamed platform state is shown separately. Error Reset is omitted because current firmware does not implement it.
  • Fast and slow logging have independent Start/Stop controls and phase/error/path indicators. Open completed log opens the final Parquet through the ordinary lazy file workflow. Stopping logging does not stop acquisition or the device.
  • Existing service → Detach leaves the service and logging running. Closing the viewer shuts down a viewer-started service; for an external service it sends device Stop and leaves logging running. Disconnect and Existing service → Shutdown send device Stop, ends acquisition, finalizes logs, and exits the service. An external CLI can attach to the same endpoint throughout.

A polling worker uses Client.read_since() at up to 30 Hz and retains at most the service's configured sample capacity. Device commands, Connect, Shutdown and Flash UZ run on a separate worker with their own service connection, so live plots keep updating while a command is in progress (polling pauses only during Flash UZ). Each publication is an immutable NumPy-backed snapshot that also carries per-bucket minima/maxima, maintained incrementally as samples arrive; wide windows are drawn from these buckets, narrow windows from raw samples, using the existing background request scheduler. The GUI does not read intermediate recording files. The default ring covers 30 seconds at the configured sample rate (300,000 samples at 10 kHz; 3,000,000 at 100 kHz). The slider's maximum automatically follows the service capacity times its configured sample period, not a measured wall clock. Your selected time depth is preserved and clamped when needed. The plot shows only the samples received so far while the buffer fills. Requests are paged independently of buffer capacity to respect the CLI response-size limit. Stale data, backend errors and cursor resynchronization are shown in the UI.

To compare live-data preparation performance between machines, run this with the viewer's installed Python environment (PowerShell shown):

.\.venv\Scripts\python.exe .\ultrazohm_dataviewer\build\benchmark_live.py --sample-rate 10000 --traces 3

On Linux, use .venv/bin/python with the same script and options. The benchmark simulates filling and wrapping the 30-second buffer and prints JSON timings for appends and preparing the visible traces. It needs no hardware. --channels defaults to 20: buffering work depends on acquired channels even when only three are plotted. These are CPU timings, not GUI FPS; they exclude the CLI, network, graphics driver and competition between worker threads. The reported ring allocation also excludes the CLI and older snapshots still held by Inspect or display readers. The status bar's RAM cache is a separate cache and does not include these live buffers.

Prototype limits: live history is RAM-bounded even while logging. Full recording history during acquisition and cloud access are future adapters using the same source/query boundary. Live windows/settings are not saved in offline sessions; analysis runs only on explicit frozen snapshots. Session times follow the CLI's nominal sampling clock; transport gaps cannot currently be reconstructed.

GUI plot, FFT, and histogram exports run in the background using captured settings. The Console reports completion or failure; one export per workspace runs at a time. Closing the workspace cancels publication of an unfinished export. Measurement-script completion terminates remaining child processes in its process group (on Windows, its job object) before manual controls are restored.

The Python panel starts hidden; open it with View → Python. Set Arguments (quote values containing spaces) and Working directory before running. Arguments are passed directly to Python without shell expansion; use forward slashes for Windows paths. Scripts receive viewer and available acquisition endpoints through UZ_DATAVIEWER_ENDPOINT and UZ_ACQUISITION_ENDPOINT. The ordinary runner stops the script process; Managed device run also provides the device Stop workflow. Python client export calls wait for publication and raise on failure. Startup Python files run sequentially after the GUI opens, so the viewer can process their requests; a failed startup script stops the sequence.

Connect starts a viewer-managed service and connects to the selected device IP. If an external service already occupies that endpoint, use Existing service → Attach. Disconnect sends shutdown (device Stop, recording finalization, and service exit) and leaves the GUI open. For a viewer-started service it waits for process exit before enabling Connect again. Each subsequent connection uses a fresh recording directory. The Existing service section contains Attach, Detach (viewer only), and Shutdown; Disconnect also shuts down an attached external service, whereas closing the GUI retains the external-service ownership policy.

To open an activated DataViewer environment without launching the GUI or a service:

./uz shell
./uz shell local   # with this checkout's CLI

The same works on Windows. Run python measurement.py or ultrazohm-cli status. Type deactivate to deactivate within the child shell, or exit to return to the original terminal.

Combined desktop distribution

Extract the Windows ZIP and launch ultrazohm-dataviewer.exe. Keep _internal beside it. Use ultrazohm-dataviewer.ps1 from PowerShell for terminal output and control commands. Python is bundled; uv and Vitis are not required for ordinary viewing. Vitis must be installed separately for firmware operations. Select the ultrazohm_sw root directory with Live Data → Browse for ultrazohm_sw, next to Browse for XSCT, or launch with gui --live-repo PATH. Offline viewing needs no selection. All available windows except Python and Application log open at startup; Navigation, Plots and Log Browser are selected. Mode selects Analysis or Live tabs without closing other windows. Use View to open Python or toggle individual windows. The source launcher behaves the same; all available windows except Python and Application log start open, with Analysis tabs selected.

The source and packaged applications use the same CLI and script worker logic. Scripts execute as ordinary __main__ files with the arguments entered in the Python panel and endpoint environment variables. No client object is injected. Source scripts use the venv's modules; packaged scripts use bundled modules. Additional dependencies can be used in an external venv with a matching CLI wheel attached to the service. Such scripts are not terminated by GUI Stop.

Writable data belongs to the selected firmware workspace, the same folder for the bundle and the source launcher: <workspace>/artifacts/_user/. Until a workspace is known (for example a bundle started outside a checkout), the viewer uses a per-user folder instead of its working directory: %LOCALAPPDATA%\UltraZohm\ultrazohm_dataviewer on Windows, ${XDG_DATA_HOME:-~/.local/share}/ultrazohm/ultrazohm_dataviewer on Linux.

The directory contains logs/ for recordings and service logs, viewer.ini for layout settings, and viewer_cache/ for optional data caches. Flash-generated javascope_*.json snapshots and editable settings.json and tools.json preferences live directly in the applicable user directory. Application packages, Tcl scripts, assets and built-in defaults remain bundled in the standalone application; workspace preferences are never written into _internal/.

After root-directory selection and successful header parsing, preparation creates missing runtime settings from the bundled CLI defaults, filtered for that workspace's observables. It also creates missing tool preferences with no XSCT selection and creates the logs directory. Existing preferences are preserved byte for byte. Layout settings are managed by the GUI framework when the viewer runs. Connect passes settings.json unchanged and rejects unavailable explicit channel assignments. Flash preserves its separate migration step and profile snapshot, reporting assignments removed by the new firmware. Edit sample_period_us and initial_channels before the next Connect; an empty initial_channels object sends no initial selections. Browsing for XSCT explicitly updates tools.json. The service rereads headers at each repository-based launch.

Save live settings, next to Browse for ultrazohm_sw, saves the current channel assignments as initial_channels in settings.json. It also writes live_view.json with connection fields, the recording parent directory, the live plot grid and signal names, axis settings, follow mode, time depth, filters, and variable input values. Selecting that workspace on a later launch restores the preferences; plot traces are restored when live data arrives. Saving while disconnected preserves the existing startup channel assignments. Restoring preferences does not connect, send variable values, or start logging. Acquisition data and an Inspect snapshot are not included; use recording or Freeze/export for those.

Two viewers on the same checkout share preferences, layout, caches and default logs. An already running acquisition service owns its configuration: use Existing service > Attach from the other viewer rather than starting another service at the same endpoint. Do not flash/build the shared Vitis workspace concurrently from two viewers. Explicit output paths and UZ_DATAVIEWER_CACHE still override their defaults.

For flashing, XSCT is detected on PATH. If it is absent, use Browse for XSCT and select the vendor launcher, such as Vitis/2022.2/bin/xsct.bat on Windows or bin/xsct on Linux. Select XSCT rather than the Vitis GUI executable. The viewer remembers the path in tools.json in its user directory and prepends its directory to PATH for itself and its child processes on subsequent starts. The system PATH is unchanged. Starting the viewer from a Vitis command prompt (or after sourcing settings64.sh) also works.

To build the combined application, run ./uz build viewer (optionally with --cli-wheel PATH for a wheel built from the same commit). The task synchronizes locked dependencies before installing that wheel. CI builds both OS wheels once, packages folder distributions from them, and tests frozen workers against the JavaScope simulator. Releases from develop and feature/uz_cli_dataviewer_testing are prereleases; main releases are stable. Each release holds two Windows ZIPs and three Python wheels (two CLI platform wheels and one viewer wheel), with both packages on PyPI.

The standalone distribution bundles repository Tcl scripts and Vitis launch presets. Its CLI workers always use those scripts, with the selected repository passed separately as the workspace root. Source/venv execution uses the checkout's Tcl scripts. JSON generation only needs the firmware headers and does not require Tcl or Vitis. Default runtime profile settings come from the CLI, not a ultrazohm_cli directory in the selected checkout.

Firmware operations still require Vitis 2022.2/XSCT, its compilers and utilities, JTAG drivers/server and hardware access, plus project firmware sources, linker scripts and hardware export (XSA/bitstream). Flash builds the existing Vitis workspace before programming; generate it first if absent. The hardware-specific psu_init.tcl comes from that hardware export; vendor fsbl.tcl and zynqmp_utils.tcl come from Vitis. They are not generic application resources.

The Windows distribution has one viewer executable and a PowerShell wrapper. Double-click ultrazohm-dataviewer.exe for the GUI; run .\ultrazohm-dataviewer.ps1 --help for terminal commands. The native ultrazohm-cli.exe is included for hardware control. Linux uses the Python wheels.

Discovery methods return typed handles, including handles nested in plot references. For example, viewer.add_signal(1, viewer.list_runs()[0]["handle"], "y") adds a recording already opened manually. CLI output remains ordinary JSON. Cancellation can stop preparation; once application-thread commit starts, the operation finishes publication and cannot be rolled back by disconnecting.

Application log starts hidden; enable it through View → Application log. The Log Browser starts at the selected checkout’s artifacts/ directory.

Python linting and formatting

This project owns its Ruff configuration and pinned version in pyproject.toml. These tasks run Ruff in an isolated tool environment and do not build or install either application. Run from the repository root:

./uz task viewer lint
./uz task viewer format
./uz task viewer format-check

On Windows, use .\uz.ps1 with the same arguments. format applies layout changes only; lint fixes and import sorting require explicit review. The enabled lint rules are F, E4, E7, E9, I, B, UP, and C4. The project's check task and CI enforce both lint and formatting.

Metadata

Release files for ultrazohm-dataviewer 0.1.88.dev0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Built distribution (wheel)

Table of built distributions (wheels) for ultrazohm-dataviewer 0.1.88.dev0
File Interpreter ABI Platform Actions
ultrazohm_dataviewer-0.1.88.dev0-py3-none-any.whl Python 3 none any Details for ultrazohm_dataviewer-0.1.88.dev0-py3-none-any.whl

Release files / ultrazohm_dataviewer-0.1.88.dev0-py3-none-any.whl

Download URL ultrazohm_dataviewer-0.1.88.dev0-py3-none-any.whl
Size 225.6 kB
Tags Python 3
SHA-256 checksum
How to use checksums
3c8e5d1fb1caff8c6be85dafc403827d1ec755d8f8c4c80d4587e055b0cc8b75
BLAKE2b-256 checksum
How to use checksums
1b09b75edb0f0c590d4d2dd4f92dee2e78329881ff6c93796e3659231df3146f
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 19, 2026.

Transparency log

Security for ultrazohm-dataviewer 0.1.88.dev0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

1 file in this release has been uploaded with provenance metadata.

Attestation for ultrazohm_dataviewer-0.1.88.dev0-py3-none-any.whl

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 19, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page