Skip to main content

ventsim-mcp

agenticeram/ventsim-mcp MCP server

An MCP server that lets AI assistants read and inspect Ventsim mine ventilation models (.vsm files).

It works on the model file itself, so Ventsim does not need to be running. It reads the geometry, fans and the results Ventsim saved in the file, and has its own experimental airflow, temperature and gas solvers for what-if questions; confirm important results in Ventsim.

Unofficial. Not affiliated with or endorsed by Howden / Chasm Consulting. "Ventsim" is their trademark. The .vsm format is undocumented; it was read from files saved by Ventsim DESIGN 6 and may change between versions.

Tools

Tool What it does
model_summary Title, Ventsim version, airway and fan counts, total length, depth range
list_airways Filter by name/notes or minimum velocity, sort by any field (airflow, length, pressure...)
get_airway Every column of one airway
list_fans Fan airways with fan model name, duty airflow, fan pressure, power
velocity_check Airways above a maximum (or below a minimum) air velocity
fan_duty_check Where each fan runs on its curve: airflow per fan, stall margin, flags fans in or near the stall region or off the curve
fan_summary Fans by model with total Fan Power as stored in the file (kW)
compare_models Diff two saved versions: added/removed airways, airflow and pressure changes
check_flow_balance Airflow mass balance at every junction (finds un-simulated or broken networks)
what_if Experimental: re-solve the network after scaling airway resistance, switching fans off or changing fan speed, report airflow changes
size_regulator Experimental: resistance, pressure drop and approximate opening area of a regulator that brings one airway to a target airflow
trace_airflow Main airflow path through an airway from intake to exhaust, with length and frictional pressure along it
simulate_airflow Experimental: solve the airflow from the model inputs alone (no saved results needed), with optional changes
simulate_heat Experimental: dry- and wet-bulb temperature and humidity after airflow changes or with extra heat and moisture sources (diesel, fire, coolers)
contaminant_spread Experimental: steady-state gas / smoke concentration downstream of release points
escape_routes Walking distance from every airway to the surface and to the nearest refuge (Ventsim's own rule), optionally with airways blocked
recirculation_check Closed loops in the airflow (fan recirculation and other circulating air)
contaminant_arrival Time for smoke or gas to reach each airway from release points
diesel_exhaust Experimental: diesel particulate (DPM) concentration and air per kW of diesel
compliance_check Airways outside velocity, diesel air, wet-bulb and escape-distance limits (your limits)
fan_select Fans from the model's fan library that meet a duty, with speed, efficiency, power and stall margin
energy_report Fan energy and yearly cost, and the airways where the air power is lost
calibrate_airflow Experimental: fit airway resistances to measured airflows (survey calibration)
list_stages Stages in the model; most analysis tools take stage= to study another one
write_results Experimental: write a copy with this server's airflow and temperatures in it
render_network Draw the network to SVG (plan or section), coloured by any field, fans marked, paths highlighted
export_csv Airways to CSV, any columns
edit_airways Experimental: write a copy with changed Notes / Group / Branch Name, fan speed or fan on/off, airway size, length or friction factor (resistance follows), or an airway closed
add_airways Experimental: write a copy with new airways (copied from an existing one, joined to the network where the ends meet)

list_airways takes units="imperial" (cfm, fpm, ft, in. w.g., hp).

All values are in the SI units Ventsim stores internally (m, m3/s, Pa, kW).

Install

pip install ventsim-mcp
# or the latest code: pip install git+https://github.com/agenticeram/ventsim-mcp

Claude Desktop / Claude Code config:

{ "mcpServers": { "ventsim": { "command": "ventsim-mcp" } } }

Then ask, for example: "Open C:\models\mine.vsm and list the 10 airways with the highest velocity."

File format notes

A .vsm is a gzip-compressed, CRLF-separated, tab-delimited text file. The airway table starts at a header line beginning MAIN<TAB>Unique No, which names all ~288 columns; the parser uses those names, never fixed positions. Reading and writing is byte-exact when nothing is edited. A .txt export of the same file (uncompressed) is read too. The CSV/NBC/XLSX exports are headerless or derived dumps of the same tables and are not supported; use the .vsm/.txt.

What-if solver (experimental)

what_if solves node pressures for the airways of the simulated stage, balancing mass flow (air expands as it warms) with dP = R*Q|Q| - Ps(Q) - NVP on every airway. What it reads from the file:

  • Stage: Stage is a bit mask and an airway that differs between stages is stored once per stage, on top of each other. The stage whose saved airflow balances is used.
  • Junctions: airway ends closer than 5 cm are one node.
  • Resistance: the effective value from the saved pressure drop (includes fittings, dampers, orifices); scaling in what_if multiplies it. Closed airways carry no air.
  • Fans: density-corrected curves, static or total pressure as the saved results show, speed by the affinity laws, curve calibrated through the saved duty point. A fan whose saved pressure drop is resistance only is treated as stopped.
  • Boundaries: portals and dead ends are held at the pressure that reproduces the saved flow.
  • Unitemised pressure terms: natural ventilation pressure, velocity-pressure changes and Ventsim's own convergence residual per airway are frozen at their saved values.

Because these inputs come from the saved state, re-solving an unchanged model reproduces Ventsim's airflow almost exactly. That checks the network was read correctly (stages, junctions, closed airways, fans); it is not an accuracy figure for changes (total absolute flow error / total flow, python bench/fit.py <folder>):

Ventsim DESIGN 6 example Airways solved Error
diamondmine 1,057 0.06 %
Tutorial2 184 0.04 %
InclinedHeatMine 810 0.02 %
the other 17 examples (CoalMine 3,403 airways, Blue_sky, Fire, HVAC, ...) < 0.01 %

Accuracy for changes. Fire and Fire2 are the same network with two airway resistances changed (x2.26 and x1.41; 25 more differ only in the last digits). Predicting Fire2 from Fire plus those changes (python bench/predict.py Fire.vsm Fire2.vsm) gives an airflow error of 0.03 % of total flow; it reproduces 96.7 % of the airflow change Ventsim computed. This is the only such pair among the shipped examples, so treat it as one data point.

Heat, density and fire effects are not re-evaluated after a change. Treat results as an estimate and confirm in Ventsim.

Simulation from inputs (experimental)

simulate_airflow does not use any saved result: resistance (Resistance Total), fan curves at their speed and count, fixed-flow airways, fixed-pressure airways (only when Ventsim's flag for it is set), closed airways, ends open to surface and dead ends (read from Ventsim's branch flags). Air is taken as incompressible and natural ventilation is ignored, unless use_saved_heat=True borrows both from the saved results. Compared with the airflow Ventsim saved (python bench/simulate.py <folder>):

Ventsim DESIGN 6 examples Error, cold With saved heat
CoalMine2, Heat Strategies, Tutorial1, RealMine, DemoMine 0.0 - 0.2 % same
Tutorial2, DevSolids, RealMine 2 0.2 - 1.2 % same
CoalMine, diamondmine, without_ducting, Natural Ventilation Effects 2 - 4 % 1.3 - 3.5 %
Fire, Fire2, InclinedHeatMine (heat-driven) 6 - 28 % 0.6 - 2 %
Blue_sky 8.5 % 5.4 %
HVACDemo, A, B (building ducts with room outlets) not supported

The remaining differences come from what the file does not spell out: heat and natural ventilation, how Ventsim applies total-pressure fan curves, leakage on ducts.

Heat and gas (experimental)

simulate_heat carries the dry-bulb temperature along the airflow, fully mixed at junctions. Each airway keeps the sensible heat Ventsim saved for it (rock, diesel, fans, other sources); the auto-compression part of it is split off and follows the new mass flow. Extra sources (kW, negative for cooling) can be added; a stopped fan's power is taken out and a speed change scales it with speed cubed. Changes are reported against the unchanged model, and baseline_fit says how well that matches Ventsim.

Moisture is carried the same way: each airway adds the water Ventsim saved as evaporating there (latent heat / 2450 kJ/kg), mixed by mass at junctions, and the wet bulb follows from dry bulb, moisture and pressure (standard psychrometrics; Ventsim's saved latent heat and wet bulbs agree with it to 0.4 % in the heat examples).

Re-running an unchanged model with its saved airflow (python bench/heat.py <folder>) is a reproduction check, not an accuracy figure for changes, because the heat comes from the same saved results. Outlet temperature, airways above 0.5 kg/s, mass-flow weighted mean / 95th percentile / worst single airway of |error|:

Ventsim DESIGN 6 example Airways Dry bulb Wet bulb
Heat Strategies 30 0.03 / 0.05 / 0.05 K 0.01 / 0.02 / 0.02 K
diamondmine 761 0.17 / 0.31 / 2.9 K 0.04 / 0.11 / 0.9 K
Natural Ventilation Effects 186 0.18 / 0.47 / 0.6 K 0.05 / 0.14 / 0.2 K
InclinedHeatMine 731 0.18 / 0.65 / 14 K 0.08 / 0.80 / 8 K
Blue_sky 506 0.33 / 0.55 / 6.4 K 0.10 / 0.33 / 3.3 K
CoalMine 1,989 0.36 / 1.6 / 8.8 K 0.41 / 1.1 / 7.3 K
Fire, Fire2 (fire airways) 147 1.1 / 2.7 / 11.5 K 3.3 / 7.4 / 11 K

There is no independent check yet: Fire2's saved temperatures are the same as Fire's, so the pair used for airflow says nothing about heat. Moisture (latent heat, wet-bulb) and the change of rock heat with air temperature are not modelled; treat temperatures after large changes as an estimate.

Heat loads stay as saved: rock heat is not computed from rock properties (Ventsim takes the virgin rock temperature and rock age from global climate settings for most airways, and where those live in the file is not known yet).

contaminant_spread gives the steady-state concentration of a gas released in airways (m3/s of pure gas): c_out = c_in + G/Q, mixed by airflow at junctions, recirculation included. It is checked against exact hand calculations in the tests only: the mine examples hold time-dependent contaminant results, and the one steady result (dust in HVACDemoB) is in an HVAC model, which is not supported. Reading the model's own source inputs (include_file_sources=True, Base Injection x Base Concentration) is an unverified interpretation of Ventsim's fields and is off by default.

contaminant_arrival gives the first arrival of smoke or gas carried at the mean air velocity, the rule behind Ventsim's Spread Time: it matches all 131 airways of Tutorial1 to within 0.1 % (python bench/spread.py <folder>). InclinedHeatMine's saved spread times are 1 - 4 % faster than its saved airflow allows, so they look like results of an earlier run; HVACDemoB is an HVAC model.

diesel_exhaust mixes diesel particulate from the engines in the model (kW x an emission factor you give, g/kWh) along the airflow. Ventsim's own saved DPM values do not follow a steady mixing model (they look time-dependent), so this tool is not checked against Ventsim.

Escape routes and recirculation

escape_routes reproduces Ventsim's distancetosurface and distancetorefuge exactly: shortest walk along airways from the middle of each airway to a surface connection or to the middle of a refuge airway (Branch Flags2 bit 5); resistances marked impassable in the model's resistance table (stoppings, roof falls) cannot be walked. All 3,262 airways of the two examples that hold these results match (python bench/escape.py <folder>). recirculation_check finds the strongly connected parts of the directed airflow. Its fan loop in Fire2 is exactly the seven airways Ventsim marks as recirculation; it also reports loops without fans (and large circulating groups in Blue_sky and RealMine) that Ventsim does not mark, so read those as "air goes round here", not as Ventsim's recirculation.

Design tools

  • fan_select reads the fan library in the model (static and total pressure, efficiency, power per curve point) and finds the speed at which each fan meets a duty. Checked on the running fans of the examples (python bench/fan_select.py <folder>): for 99 of 103 fans with a library curve (for the other 4 no speed from 20 to 250 % fits), the fan's own curve meets its saved duty, at a speed within 1.3 points of the saved Fan Speed (6 points where only a total-pressure curve is given).
  • energy_report uses the saved fan power (Ventsim's Fan Power = airflow x fan total pressure / efficiency) and splits the air power over the airways.
  • compliance_check limits default to common practice values (0.25 - 6 m/s, 20 m/s in shafts, 0.06 m3/s per diesel kW, 28 C wet bulb); they are not any particular regulation, so pass the values that apply to you.
  • calibrate_airflow fits resistance factors to measured airflows by least squares on the what_if solver. Using Fire2's airflow in the 27 airways whose stored resistance differs from Fire as "measurements" on Fire (python bench/calibrate.py Fire.vsm Fire2.vsm) brings the whole network to within 0.002 % of Fire2's airflow in 8 s. The resistances themselves are not recovered: the two airways that really changed (x2.26 and x1.41) come out as x1.52 and x1.08, the rest of the change lands on airways in series with them, which the measurements cannot tell apart. Treat the factors as one fit, not as measured values.
  • write_results writes airflow, end pressures, airway pressure drop, fan pressure and temperatures into a copy (what_if solver by default). The other tools read such a copy consistently: what_if on a written copy reproduces it with 0.00 % error on Fire and CoalMine. Heat terms and gases are left as they were; the copies have not been opened in Ventsim itself yet.
  • compliance_check takes the wet bulb Ventsim saved.
  • Stages: simulate_airflow(stage=...) solves another stage from its inputs and escape_routes(stage=...) checks its escape routes; the other tools use the saved results, which belong to the saved stage.
  • Closing an airway (edit_airways, field Closed) writes it the way Ventsim stores closed airways in the examples: resistance type 1, resistance 1000.

Leakage: in these examples leakage paths are ordinary high-resistance airways, already in the network solve; nothing else is needed for them.

Editing geometry (experimental)

edit_airways accepts Width, Height, Length and kFactor. Area and perimeter follow the airway shape (rectangle, round; other profiles are scaled) and Resistance Total is scaled with the Atkinson relation R ~ k * P * L / A^3, so shock and density factors Ventsim folded into it are kept in proportion. add_airways copies an existing airway to new end points; it does not copy fans, fixed flows or pressures, heat or gas sources. A new end joins the network where it meets an existing airway end (not at a surface connection, which it would close); an end that meets nothing is a dead end unless listed in open_ends. Run simulate_airflow on the copy for the new airflow. Edited and added copies have not yet been opened in Ventsim itself; check them there before relying on them.

Limits

  • Fire dynamics, dispersion in time-dependent contaminant spread and rock heat from rock properties stay in Ventsim.
  • Fan curve pressure at the duty point differs from Ventsim's saved value by about 0.7 % (median); Ventsim applies a correction the file does not hold. Fan airflow is exact.
  • Building HVAC examples (HVACDemo, A, B) are not supported: their ducts connect through room objects the airway table does not hold.
  • Tested on the 20 example models shipped with Ventsim DESIGN 6 (up to 6,700 airways). Other versions untested.

Contributing

Issues and pull requests are welcome; see CONTRIBUTING.md. Questions and ideas go to Discussions.

Development

pip install -e ".[test]"
pytest

MIT licence.

Metadata

Release files for ventsim-mcp 0.11.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for ventsim-mcp 0.11.0
File Size Uploaded Provenance Actions
ventsim_mcp-0.11.0.tar.gz 64.8 kB With provenance Details for ventsim_mcp-0.11.0.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for ventsim-mcp 0.11.0
File Interpreter ABI Platform Actions
ventsim_mcp-0.11.0-py3-none-any.whl Python 3 none any Details for ventsim_mcp-0.11.0-py3-none-any.whl

Total release size: 117.2 kB

Release files / ventsim_mcp-0.11.0.tar.gz

Download URL ventsim_mcp-0.11.0.tar.gz
Size 64.8 kB
Tags Source
SHA-256 checksum
How to use checksums
83d53d98def6cb3ceb05fe5a454bcf0cc9dedf5894fc460d27b3da750a160269
BLAKE2b-256 checksum
How to use checksums
5a2269475e3d185c945fc0b19e1776da221fa4b33d05b79cb32bfe4f4b57c59f
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 26, 2026.

Transparency log

Release files / ventsim_mcp-0.11.0-py3-none-any.whl

Download URL ventsim_mcp-0.11.0-py3-none-any.whl
Size 52.4 kB
Tags Python 3
SHA-256 checksum
How to use checksums
09528fbd393135328b3e0413ec6c98b6722b1d3c1f81e5fe526fff6e60fd47b1
BLAKE2b-256 checksum
How to use checksums
0064a64d3ec75a32a40b32a4922af7185a27e87d2a9b9368dd125e22fee85000
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 26, 2026.

Transparency log

Security for ventsim-mcp 0.11.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

Both files in this release have been uploaded with provenance metadata.

Select from 2 files

Attestation for ventsim_mcp-0.11.0.tar.gz

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 26, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page