Skip to main content

VMware Storage

Author: Wei Zhou, VMware by Broadcom — wei-wz.zhou@broadcom.com This is a community-driven project by a VMware engineer, not an official VMware product. For official VMware developer tools see developer.broadcom.com.

English | 中文

VMware vSphere storage management: datastores, iSCSI, vSAN, and read-only Fibre Channel / multipath diagnostics — 15 MCP tools, domain-focused and lightweight.

Split from vmware-aiops for lighter context and local model compatibility.

License: MIT

Upgrading to 2.0

2.0 renames 10 of its MCP tools (all but the four that already started with a verb) so every name starts with a verb (e.g. fc_adapter_list → list_fc_adapters, storage_device_paths → list_storage_device_paths, storage_iscsi_add_target → add_iscsi_target). The full old → new table is in RELEASE_NOTES.md. Three tools also change a parameter: browse_datastore and scan_datastore_images take datastore_name (was ds_name, now the same as vmware-aiops' browse_datastore), and list_all_datastores gains an optional limit (same as vmware-monitor's). Everything else stays: same tools, safety gates and CLI commands (the CLI still takes the datastore name as before). If an agent prompt, script or ~/.vmware/rules.yaml names a tool, update it — though deny rules written with the old names keep working with vmware-policy ≥ 1.18 (vmware-audit policy lists any rule the renames widened), and vmware-pilot ≥ 1.13 translates old names in saved workflows. If an install older than 2.0 shares that rules.yaml, give it vmware-policy ≥ 1.18.2 too: it matches each rule against both the old and the new name, so one file serves both.

Companion Skills

Skill Scope Tools Install
vmware-aiops ⭐ entry point VM lifecycle, deployment, guest ops, clusters 49 uv tool install vmware-aiops
vmware-monitor Read-only monitoring, alarms, events, VM info 27 uv tool install vmware-monitor
vmware-vks Tanzu Namespaces, TKC cluster lifecycle 20 uv tool install vmware-vks
vmware-nsx NSX networking: segments, gateways, NAT, IPAM 33 uv tool install vmware-nsx-mgmt
vmware-nsx-security DFW microsegmentation, security groups, Traceflow 21 uv tool install vmware-nsx-security
vmware-aria Aria Ops metrics, alerts, capacity planning 28 uv tool install vmware-aria

Quick Install

# Via PyPI
uv tool install vmware-storage

# Or pip
pip install vmware-storage

Offline / Air-Gapped Install (from source)

This project uses the modern PEP 517 build system (hatchling), so there is no setup.py by design — that is expected, not a missing file. If you cloned the source and hit ERROR: File "setup.py" or "setup.cfg" not found ... editable mode currently requires a setuptools-based build, your pip is older than 21.3 and cannot do an editable (-e) install with a non-setuptools backend. Editable mode is a developer convenience, not needed to run the tool — do one of:

# From the source tree — a normal (non-editable) install builds a wheel:
pip install .              # NOT  pip install -e .

# ...or upgrade pip first, and editable works too:
pip install --upgrade pip && pip install -e .

For a truly air-gapped host, build the wheels on a connected machine and copy them over — the target then needs no network:

# On a connected machine, collect this package + its dependencies as wheels:
pip wheel . -w dist        # → dist/*.whl   (or: uv build, for just this package)

# Copy dist/ to the air-gapped host, then install offline:
pip install --no-index --find-links dist vmware-storage

Configuration

mkdir -p ~/.vmware-storage
cp config.example.yaml ~/.vmware-storage/config.yaml
# Edit with your vCenter/ESXi credentials

echo "VMWARE_MY_VCENTER_PASSWORD=your_password" > ~/.vmware-storage/.env
chmod 600 ~/.vmware-storage/.env

# Verify
vmware-storage doctor

MCP Tools (15)

Category Tools Type
Datastore list_all_datastores, browse_datastore, scan_datastore_images, list_cached_images Read
iSCSI enable_iscsi, get_iscsi_status, add_iscsi_target, remove_iscsi_target, rescan_storage Read/Write
vSAN get_vsan_health, get_vsan_capacity, get_vsan_efficiency Read
FC / multipath list_fc_adapters, list_storage_device_paths Read
Access get_access_info — which account the server uses and whether it holds each tool's vSphere privileges (root folder) Read

Auto-Remediation Patterns (PoC)

The patterns/ directory hosts L5 auto-remediation candidate patterns from the Enterprise Harness Engineering framework. The first PoC pattern, patterns/iscsi-target-stale-rescan.yaml, describes an iSCSI HBA rescan as a low-risk, reversible, repeatable operation. The pattern schema is documented here only — runtime enforcement is not yet wired up, so this is a reference design, not production auto-remediation.

Common Workflows

Set Up iSCSI Storage on a Host

  1. Enable iSCSI adapter: vmware-storage iscsi enable esxi-01
  2. Add target: vmware-storage iscsi add-target esxi-01 10.0.0.100
  3. Verify: vmware-storage iscsi status esxi-01

The add-target command automatically rescans storage. Use --dry-run to preview any write command first.

Find Deployable Images Across Datastores

  1. List all datastores: vmware-storage datastore list
  2. Scan for images: vmware-storage datastore scan-images datastore01
  3. Browse with a pattern: vmware-storage datastore browse datastore01 --pattern "*.iso"

vSAN Health Assessment

  1. Check health: vmware-storage vsan health Cluster-Prod
  2. Check capacity: vmware-storage vsan capacity Cluster-Prod
  3. If issues found, investigate with vmware-monitor for alarms and events

Check Fibre Channel Paths

  1. Dead or disabled paths behind a datastore: vmware-storage paths devices --datastore ds-fc-01
  2. Hosts that see a shared device through a different number of paths than their peers, or not at all: vmware-storage paths devices --cluster Cluster-Prod --only-differences
  3. WWPNs for the SAN team: vmware-storage paths fc-adapters --cluster Cluster-Prod

Hosts that could not be read are listed in hosts_not_read and are never reported as missing a device. Path states are reported as vSphere reports them — standby is not flagged.

CLI

# Datastore
vmware-storage datastore list
vmware-storage datastore browse datastore01
vmware-storage datastore scan-images datastore01

# iSCSI
vmware-storage iscsi status esxi-01
vmware-storage iscsi enable esxi-01
vmware-storage iscsi add-target esxi-01 192.168.1.100
vmware-storage iscsi remove-target esxi-01 192.168.1.100
vmware-storage iscsi rescan esxi-01

# vSAN
vmware-storage vsan health Cluster-Prod
vmware-storage vsan capacity Cluster-Prod

# Fibre Channel / multipath (read-only)
vmware-storage paths fc-adapters --cluster Cluster-Prod
vmware-storage paths devices --datastore ds-fc-01

# Diagnostics
vmware-storage doctor

MCP Server

After uv tool install vmware-storage, start the MCP server with one command (v1.5.15+):

# Recommended — single command, no network re-resolve
vmware-storage mcp

# With a custom config path
VMWARE_STORAGE_CONFIG=/path/to/config.yaml vmware-storage mcp

# Or via Docker
docker compose up -d

Agent Configuration

Add to your AI agent's MCP config:

{
  "mcpServers": {
    "vmware-storage": {
      "command": "vmware-storage",
      "args": ["mcp"],
      "env": {
        "VMWARE_STORAGE_CONFIG": "~/.vmware-storage/config.yaml"
      }
    }
  }
}
Alternative: uvx (no install) or legacy entry point
# Run without installing (requires PyPI access each launch)
uvx --from vmware-storage vmware-storage mcp

# Legacy entry point (still works, kept for backward compatibility)
vmware-storage-mcp

Behind a corporate TLS proxy? uvx may fail with invalid peer certificate: UnknownIssuer. Use the recommended vmware-storage mcp form above (no network needed), or set UV_NATIVE_TLS=true.

Why a Separate Skill?

vmware-aiops has 61 MCP tools — too heavy for local LLMs (7B-14B). By splitting storage into its own skill:

  • 15 tools — fits comfortably in small model context windows
  • Domain-focused — storage admins get only what they need
  • Least privilege — can run under a vCenter service account with storage read-only permissions
  • Composable — use alongside vmware-monitor or vmware-aiops as needed

Version Compatibility

Python: 3.10+ (since v1.5.27 — previously 3.11+). Tested on 3.10 / 3.11 / 3.12.

vSphere / VCF Support Notes
VCF 9.1 / vSphere 9.1 Full Released 2026-05-12. pyVmomi+vSAN SDK <10.0 works via SOAP.
VCF 9.0 / vSphere 9.0 Full pyVmomi 8.0.3+ with bundled vSAN SDK connects to vSphere 9.
8.0 Full vSAN SDK built into pyVmomi 8.0.3+
7.0 Full All storage APIs work
6.7 Compatible iSCSI + datastore features work; vSAN limited

Official Broadcom References

Safety

Feature Description
Read-heavy 11/15 tools are read-only
Preview by default (MCP) The 4 write tools take confirm (default false): a call without it changes nothing and returns blast_radius (host, adapters, and for target removal the paths, devices and datastores behind the target). confirm=true is refused when a datastore would lose every path or part of the blast radius could not be read. dry_run is a deprecated alias
Input validation IP addresses and ports validated before iSCSI operations
Audit logging All operations logged to ~/.vmware-storage/audit.log
No VM operations Cannot create, delete, or modify VMs
Credential safety Passwords only from environment variables, never config files

Troubleshooting

Problem Cause & Fix
iSCSI enable fails with "already enabled" Not an error — adapter is already active. Run iscsi status to see configured targets.
"Datastore not found" when browsing Datastore names are case-sensitive. Run datastore list to get the exact name.
get_vsan_health returns overall_health: null null = not asked (see health_not_queried_reason), never a measurement; a string is always vSAN's own answer, including its own "unknown". Usual cause: connected to standalone ESXi, but the health service runs in vCenter.
Rescan doesn't discover new LUNs Wait 15-30 seconds after adding targets, then rescan again. Verify target IP is reachable from ESXi.
"Password not found" error Variable names follow VMWARE_<TARGET_UPPER>_PASSWORD (hyphens → underscores). Check ~/.vmware-storage/.env.
doctor fails with "no vSphere role", or every command fails with "session is not authenticated" The login works but the account has no vSphere role. Assign one (Read-Only or higher) on the vCenter root folder (Administration > Access Control > Global Permissions). Mid-run, the same fault can be an expired session: run the command again.
Connection timeout to vCenter Use vmware-storage doctor --skip-auth to bypass auth checks on high-latency networks.
"Datastore browse did not finish within Ns" The datastore is very large or busy. Narrow the search with a sub-path and a specific pattern (e.g. datastore browse ds01 --path templates --pattern "*.ova") instead of browsing the root — do not just retry the same broad browse.

Remote access (HTTPS) and limiting tools

By default vmware-storage mcp speaks stdio to one local client and offers every tool. Two options change that (vmware-policy ≥ 1.21.0).

Serve over HTTPS so clients on other machines can connect. Every caller needs a bearer token:

vmware-audit token create alice          # prints the token once; give it to alice
vmware-audit token list                  # names only
vmware-audit token revoke alice          # refused from its next request, no restart
vmware-storage mcp --transport https --host 0.0.0.0 --port 8443 \
    --cert /etc/vmware-mcp/server.pem --key /etc/vmware-mcp/server-key.pem \
    --public-name mcp.example.com

Connect a client (Claude Code shown; any MCP client that supports streamable HTTP and custom headers works):

claude mcp add --transport http vmware-storage https://mcp.example.com:8443/mcp \
    --header "Authorization: Bearer $VMWARE_MCP_TOKEN"
{
  "mcpServers": {
    "vmware-storage": {
      "type": "http",
      "url": "https://mcp.example.com:8443/mcp",
      "headers": { "Authorization": "Bearer ${VMWARE_MCP_TOKEN}" }
    }
  }
}
  • The server will not start without a token, refuses Host/Origin values outside --public-name, and checks before it binds that unauthenticated requests get 401. Use a certificate your clients trust for those names.
  • Behind a TLS-terminating reverse proxy on the same machine use --transport http --host 127.0.0.1 --public-name mcp.example.com and pass the Authorization header through.
  • Behind a load balancer or gateway on another machine, keep --transport https (a self-signed certificate is fine), list in --public-name the host name the balancer sends as Host, and have it forward Authorization. Its health probe can use GET /healthz, which needs no token and returns only {"status": "ok"} (vmware-policy ≥ 1.23.0).
  • Send traceparent or X-Request-ID with each request to have it stored on the audit row; vmware-audit log --correlation-id ID then finds the calls behind one platform request.
  • The audit log records each caller as token:<name>. Calls run side by side, also on the same target: the server keeps up to VMWARE_MCP_POOL_SIZE (default 2) sessions per target, each one a login on that target, and a call waits at most 300 s for a free session (vmware-policy ≥ 1.22.0).
  • Everyone who can reach the endpoint acts with this server's account. Tokens identify callers; they grant nothing on the platform. Run one endpoint per privilege level. vmware-storage access-info shows which account that is and what it may do.

Offer only read tools, plus the writes you choose:

vmware-storage mcp --expose read --allow-write enable_iscsi
# or: VMWARE_STORAGE_MCP_EXPOSE=read VMWARE_STORAGE_MCP_ALLOW_WRITE=enable_iscsi vmware-storage mcp

Tools not offered do not appear in the client's tool list. A bad value or an unknown write tool stops the server (exit 2). This limits what clients are offered; it is not authorization, so the account itself should be least-privilege.

Details: skills/vmware-storage/references/setup-guide.md ("Serving MCP over HTTPS", "Limiting which tools are offered").

License

MIT

Metadata

Release files for vmware-storage 2.3.1

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for vmware-storage 2.3.1
File Size Uploaded
vmware_storage-2.3.1.tar.gz 331.4 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for vmware-storage 2.3.1
File Interpreter ABI Platform
vmware_storage-2.3.1-py3-none-any.whl Python 3 none any Details

Total release size: 414.3 kB

Release files / vmware_storage-2.3.1.tar.gz

Download URL vmware_storage-2.3.1.tar.gz
Size 331.4 kB
Tags Source
SHA-256 checksum
How to use checksums
04291cff927ac7ba5ad87a3ea17309f68a6aa7b1868f805db726a2941fdfe3a8
BLAKE2b-256 checksum
How to use checksums
c8fc3f4248882adbcd7a53d44c4142d78b885a7eb6f1ed7c1352cd49d4a0c76e
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.13.12

Release files / vmware_storage-2.3.1-py3-none-any.whl

Download URL vmware_storage-2.3.1-py3-none-any.whl
Size 82.9 kB
Tags Python 3
SHA-256 checksum
How to use checksums
71270158ae07b4ca791dd73b785b241b3e93b78e9cb365075fb2d206e0666927
BLAKE2b-256 checksum
How to use checksums
5b02889f1f33814b0e305592cecbb3939691a3e0c3a3b2b616d8e2e4ca59665b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.13.12

Release history Release notifications | RSS feed

2.4.0

2 release files

This release

2.3.1 This release

2 release files

2.3.0

2 release files

2.2.0

2 release files

2.1.0

2 release files

2.0.0

2 release files

1.12.1

2 release files

1.12.0

2 release files

1.11.0

2 release files

1.10.0

2 release files

1.9.3

2 release files

1.9.2

2 release files

1.9.1

2 release files

1.9.0

2 release files

1.8.16

2 release files

1.8.15

2 release files

1.8.14

2 release files

1.8.13

2 release files

1.8.12

2 release files

1.8.11

2 release files

1.8.9

2 release files

1.8.8

2 release files

1.8.7

2 release files

1.8.5

2 release files

1.8.4

2 release files

1.8.3

2 release files

1.8.2

2 release files

1.8.1

2 release files

1.8.0

2 release files

1.7.7

2 release files

1.7.5

2 release files

1.7.4

2 release files

1.7.3

2 release files

1.7.2

2 release files

1.7.1

2 release files

1.7.0

2 release files

1.6.1

2 release files

1.6.0

2 release files

1.5.39

2 release files

1.5.38

2 release files

1.5.37

2 release files

1.5.36

2 release files

1.5.35

2 release files

1.5.29

2 release files

1.5.28

2 release files

1.5.27

2 release files

1.5.26

2 release files

1.5.23

2 release files

1.5.18

1 release file

1.5.15

2 release files

1.5.14

2 release files

1.5.13

2 release files

1.5.12

2 release files

1.5.11

2 release files

1.5.10

2 release files

1.5.8

2 release files

1.5.7

2 release files

1.5.6

2 release files

1.5.5

2 release files

1.5.4

2 release files

1.5.3

2 release files

1.5.0

2 release files

1.4.9

2 release files

1.4.8

2 release files

1.4.7

2 release files

1.4.6

2 release files

1.4.5

2 release files

1.4.4

2 release files

1.4.3

2 release files

1.4.1

2 release files

1.4.0

2 release files

1.3.5

2 release files

1.3.4

2 release files

1.3.3

2 release files

1.3.2

2 release files

1.3.1

2 release files

1.3.0

2 release files

1.2.1

2 release files

1.2.0

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page