Skip to main content

A library for interacting with Wiliot's Deployment Tools

Project description

PyWiliot: wiliot-deployment-tools

wiliot-deployment-tools is a python library for accessing Wiliot's Deployment and Automation Tools. This python package includes the following CLI utilities:

  • Automatic Configuration Tool (wlt-config)
  • Calibration Management Tool (wlt-clibration-mgmt)
  • Firmware Update Tool (wlt-firmware)
  • Power Management Tool (wlt-power-mgmt)
  • Log Viewer (wlt-log)
  • Connectivity Analyzer (wlt-connectivity-analyzer)
  • Gateway Certificate (wlt-gw-certificate)
  • Power Optimization Tool (wlt-power-optimization)

Installing wiliot-deployment-tools

pip install wiliot-deployment-tools

Using wiliot-deployment-tools

This package includes the following CLI Utilities:

Automatic Configuration Tool

Automatically connects to all Gateways / Bridges in the location specified, and configure them to optimal parameters.

usage: wlt-config -owner OWNER -location LOCATION [-ota] [-no_gp_zone] [-pacing_interval PACING_INTERVAL] [-ignore_bridges [IGNORE_BRIDGES [IGNORE_BRIDGES ...]]] [--expected_num_brgs EXPECTED_NUM_BRGS]

required arguments:
  -owner OWNER         Platform owner id
  -location LOCATION   Location name in Wiliot platform. If location has ' ' in name, input location wrapped with double quotes: --location "LOCATION NAME"

additional (optional) arguments:
  -ota         Updating FW version to latest for all devices
  -no_gp_zone          don't use Global pacing group by zone (all bridges will be GPG=0)
  -pacing_interval PACING_INTERVAL
                        Pacing interval for all devices
  -ignore_bridges [IGNORE_BRIDGES [IGNORE_BRIDGES ...]]
                        bridges to ignore in the tool - their configuration won't be changed
  -expected_num_brgs EXPECTED_NUM_BRGS
                        Number of expected bridges in location. The tool will try to connect to all bridges (excluding those specified in ignore bridges) until reaching expected number.

example usage: wlt-config --owner wiliot --location "My Deployment" --ota_upgrade --pacing_interval 10 --ignore_bridges 1234ABCD0123

Calibration Management

Configure Wiliot Bridge calibration mode, broadcast is optional

usage: wlt-calibration-mgmt -owner OwnerID -brg BridgeID -gw GW -mode CalibrationMode [-timeout TIMEOUT]
usage (broadcast): wlt-calibration-mgmt -owner OwnerID -gw GW -mode CalibrationMode [-timeout TIMEOUT]

required arguments:
  -owner OWNER  Owner ID
  -brg BRG      Bridge ID (required only for non broadcast)
  -gw GW        GW ID to configure bridge (required only for broadcast)
  -mode Mode    CalibrationMode on of 3 options: 0-regular, 1-no ch37, 2-ch37 on data only

optional arguments:
  -timeout TIMEOUT      Minutes timeout (not required, defaults to 5 minutes)

  example usage: wlt-calibration-mgmt -owner wiliot -brg 0123ABCD -gw AB1234CD -mode 1

Firmware Update

Update Wiliot Gateways and Bridges firmware version OTA.

Print Available Versions

Prints all avaliable Firmware versions for update for every GW Type

usage: wlt-firmware -owner OWNER [-beta] versions

optional arguments:
  -beta              show available beta versions / update to beta firmware

example usage: wlt-firmware -o wiliot versions

Firmware Update

Run OTA Process, first updating specified GWs to latest / specified FW version. Afterwards seuqentially update each specified Bridges / all Bridges to the same Firmware version.

usage: wlt-firmware update -owner OWNER [-beta] [-version VERSION] [-gw GW [GW ...]] [-brg BRG [BRG ...]] [-all_brgs] [-ignore_bridges IGNORE_BRIDGES [IGNORE_BRIDGES ...]] [-action]


optional arguments:
 -beta              show available beta versions / update to beta firmware
 -version VERSION      Desired version. if not specified, will update to latest available version
 -gw GW [GW ...]       Gateways to update (multiple allowed)
 -brg BRG [BRG ...]    Bridges to update (multiple allowed)
 -all_brgs             update all bridges connected to Gateways
 -ignore_bridges IGNORE_BRIDGES [IGNORE_BRIDGES ...]
                       bridges to ignore
 -action               update using action API
 -force                update bridge even if its already in desired version (applicable only with -action)

 example usage: wlt-firmware -o wiliot update -gw GW0123 -all_brgs

Power Management

Use Wiliot Bridge power management functionality

Enter Power Management

Configure Specified Bridges to work in power management configuration.

usage: wlt-power-mgmt -o OwnerID enter -brg BridgeID -sleepduration SLEEPDURATION -onduration ONDURATION [-keepalive KEEPALIVE] [-scan SCAN] [-ledoff] [-gw GW] [-timeout TIMEOUT]

required arguments:
  -owner OWNER  Owner ID
  -brg BRG      Bridge ID

optional arguments:
  -sleepduration SLEEPDURATION
                        Sleep duration (minutes)
  -onduration ONDURATION
                        On duration (seconds) *rounds to nearest 30 second interval*
  -keepalive KEEPALIVE  Keep alive period (seconds) *rounds to nearest 5 second interval* (not required, defaults to 30 seconds)
  -scan SCAN            Keep alive scan (milliseconds) *rounds to nearest 10 millisecond interval* (not required, defaults to 300 milliseconds)
  -ledoff               Configure LEDs off (on by default)
  -gw GW                GW ID to configure bridge (required only for broadcast mode)
  -timeout TIMEOUT      Minutes timeout (not required, defaults to 5 minutes)

  example usage: wlt-power-mgmt -o wiliot enter -brg 0123ABCD -sleepduration 5 -onduration 60

Exit Power Management

Return specified bridges out of power management mode and into normal working mode.

usage: wlt-power-mgmt -o OwnerID exit -brg BridgeID [-gw GW] [-no_config] [-timeout TIMEOUT]

required arguments:
  -owner OWNER  Owner ID
  -brg BRG      Bridge ID

optional arguments:
  -gw GW            GW ID to configure bridge (not required)
  -no_config        If used, GW will not change to optimal configuration
  -timeout TIMEOUT  Minutes timeout (not required, defaults to 5 minutes)

example usage: wlt-power-mgmt -o wiliot exit -brg BridgeID

Log Viewer

View Wiliot Gateway logs

usage: wlt-log -owner OWNER -gw GW

Log Viewer - CLI Tool to view Wiliot Gateway logs

required arguments:
  -owner OWNER  Owner ID
  -gw GW        Gateway ID

Connectivety Analyzer

Check the RSSI values for GW-> Bridge transmissions (as received at the bridge) Can operate by: location, bridges or gateways Return the bridges with low connection Additional option: bridge-gw connectivity log printer (-bridge_log)

usage (connectivity check): wlt-connectivity-analyzer -owner OWNER -location Location
usage (bridge-gw conn log): wlt-connectivity-analyzer -owner OWNER -brg BRG -bridge_log

required arguments:
  -owner OWNER  Owner ID
  -bridge_log (Only for bridge-gw conn log)
  -brg BRG (Only for bridge-gw conn log)


optional arguments:
  -gws GwsList         List of gateways IDs to check connection to the bridges they see
  -brgs BridgesList    List of bridges IDs to check connection 
  -location Location   Location name (as written in platform) to check all bridges in

For more documentation and instructions, please contact us: support@wiliot.com

Gateway Certificate

Test Wiliot GWs capabilities. The GW Certificate includes different test that run sequentially to test each capability reported by the GW.

Coupling Test

The test switched the GW to an external MQTT Broker and uses a BLE Simulator (Wiliot WIFI GW connected using UART) to simulate bridges and test the coupling capability of the tested GW (Couple together Data and SideInfo packets) The test inclued the following stages:

  • STAGES = [InitStage, OneBrgStage, ThreeBrgInitStage, ThreeBrgStage]
  • Init Stage - Send 4 packet pairs (Data+SI) from 1 BRG, testing maximum/minimum RSSI and NFPKT Values encoded in SI packet
  • One Bridge Stage - Send packet pairs at increasing duplication (1->10) and increasing time delay between packets (15->255 ms) from 1 bridge, including simulated packet error.
  • Three Bridge Init Stage - send same data packet from 3 different bridges, each with different SI.
  • Three Bridge Stage - send same data packet from 3 different bridges, at increasing duplication (1->10) and increasing time delay between packets for each bridge (30->255). The test logs all sent packets, and all received packets from the tested GW in log files and outputs a summary of all sent packets in a CSV file (filepath specified at runtime).

GW Certificate Release Notes:

Version 4.1.7:

  • Downlink Test
  • Add incremental stage (optional)
  • Support for GCP Cloud
  • Code documentation overhaul

Version 4.1.4:

  • Randomize bugfix

Version 4.1.3:

  • Bugfixes
  • Support for Android
  • Support for python 3.11

Version 4.1.0:

  • Coupling Test
  • Add CSV Output
  • Calculate test run

Version 4.0.13:

  • Initial Release (Alpha)
usage: wlt-gw-certificate [-h] -owner OWNER -gw GW [-test] [-random] [-legacy]

Gateway Certificate - CLI Tool to test Wiliot GWs

optional arguments:
  -h, --help    show this help message and exit
  -test         If flag used, use test environment (prod is used by default)
  -random       randomize packets (if not used same packets will be sent for each run)
  -legacy       use legacy DevMode

required arguments:
  -owner OWNER  Owner ID
  -gw GW        Gateway ID

Power Optimization Tool:

Plots the gain-current curve for a given bridge to help determine optimal configuration in terms of power consumption

usage: wlt-power-optimization -bridge_type BridgeType -dc DutyCycle -gw GW -rxtx_period RxTxPeriod


required arguments:
  -bridge_type BRIDGE_TYPE  The bridge type that will be analyzed
  -dc DC      Duty cycles to compare in the plot
  -rxtx_period RXTX_PERIOD        The rxtx periods in mili-sec corresponding to the duty cycles
  

  example usage: wlt-power-optimization -bridge_type minew -dc 0.33 0.5 -rxtx_period 15 20

Release Notes:

Version 4.1.9:

  • Support for GCP/AWS in connectivity analyzer
  • Allowing connectivity analyzer to run without specifying a location
  • Support FW version 3.16 - MEL modules

Version 4.1.8:

  • Added power optimization tool to package

Version 4.1.7:

  • Support for GCP/AWS cloud in extended_api
  • Support FW 3.15

Version 4.1.1:

  • Bridge-Gw connectivity log print

Version 4.1.0:

  • Custom message support
  • GW Certificate - coupling test
  • Fixes for calibration management

Version 4.0.13:

  • Add Gateway Certificate (Alpha)

Version 4.0.12:

  • Add new Connectivity Analyzer

Version 4.0.11:

  • Add broadcast to calibration management
  • Bugfixes for power management using android GW

Version 4.0.10:

  • Internal fixes

Version 4.0.8:

  • Support for python 3.11
  • Added new calibration mgmt tool

Version 4.0.7:

  • Android power management support
  • Bugfix when no gateway logs found

Version 4.0.4:

  • Bugfixes, add relevant printouts to CLI to help understand errors.

Version 4.0.3:

  • Initial release of CLI tools suite - Automatic Configuration Tool, Firmware Update, Power Management, Log Viewer.

Version 4.0.0:

  • First version

The package previous content was published under the name 'wiliot' package. for more information please read 'wiliot' package's release notes


MacOS Installation

Getting around SSL issue on Mac with Python 3.7 and later versions

Python version 3.7 on Mac OS has stopped using the OS's version of SSL and started using Python's implementation instead. As a result, the CA certificates included in the OS are no longer usable. To avoid getting SSL related errors from the code when running under this setup you need to execute Install Certificates.command Python script. Typically you will find it under

/Applications/Python\ 3.7/Install\ Certificates.command

Python 3 on MacOS

The default Python version on mac is 2.x. Since Wiliot package requires Python 3.x you should download Python3 (e.g. Python3.7) and make python 3 your default. There are many ways how to do it such as add python3 to your PATH (one possible solution https://www.educative.io/edpresso/how-to-add-python-to-the-path-variable-in-mac)

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

wiliot-deployment-tools-4.1.11.tar.gz (19.4 MB view hashes)

Uploaded Source

Built Distribution

wiliot_deployment_tools-4.1.11-py3-none-any.whl (886.9 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page