franklinwh-direct-connect-api
This library is a proof-of-concept demonstration of how to talk to a FranklinWH aGate
gateway over the (undocumented, unofficial) FranklinWH Direct Connect local API — the
JSON cmdType frames exchanged over TCP/9000. It is the lower-level device↔broker
channel that the cloud sendMqtt REST relay (see
franklinwh-cloud) is layered on top of.
On the names. Direct Connect is FranklinWH's own term for the gateway's local protocol. This project implements that protocol; it is the library and CLI, not an application — the Direct Connect Bridge is the application built on top of it, and is where a REST API, MQTT, Home Assistant entities and a web UI live. Adopting FranklinWH's term implies no affiliation with, endorsement by, or support from FranklinWH.
The distribution on PyPI is franklinwh-direct-connect-api, the import package is
franklinwh_direct_connect_api, and the CLI command is franklinwh-direct-connect. The
pre-0.4.0 spellings still work, because removing them would break existing code: importing
franklinwh_local returns the same module objects (so isinstance and subclassing hold
across both spellings), the franklinwh-local command is the same entry point, and
LocalClient/LocalTransport remain aliases of DirectConnectClient/
DirectConnectTransport. Importing the old package emits a DeprecationWarning, and the
aliases are scheduled for removal in 0.6.0 — the date was previously 0.5.0, which
shipped with them still in place.
It is not intended for production use, and there is no guarantee it is compatible with
your FranklinWH gateway(s), aPower(s) or connectivity — now or in the future. FranklinWH
may change, block or deprecate this interface at any time. It has been tested on a local
area network against one aGate X with one aPower, most recently on firmware
IBG_VER V12R02B60D00_260924 / protocolVer V1.12.02 (read 2026-10-31). One site on one
firmware is a hypothesis, not a compatibility matrix: multi-aPower behaviour in particular
is unobserved, and anything this documentation marks UNCONFIRMED has not been proven on
any hardware.
You do not need a gateway to try it. Run the built-in emulator and point the whole CLI and library at it — a deterministic synthetic aGate with N aPowers, live telemetry, energy history, smart circuits and writes that persist, so you can see the thing work before you connect real hardware:
franklinwh-direct-connect emulate # a fake aGate (port 19000)
franklinwh-direct-connect --host 127.0.0.1 --port 19000 power_flow # ... talk to it
TCP 9000 is a reserved port and not available to this emulator. It refuses to start on 9000 and defaults to 19000.
9000belongs to a real aGate and to the FranklinWH Gateway Emulator — the official emulator, which is deliberately transparent, so something answering on 9000 is meant to be indistinguishable from a gateway. This library's mock must stay distinguishable from one: a mock left on 9000 once showed up in a LAN scan as9000/sendMqtt CONFIRMED, which makes every discovery result untrustworthy.
proxyis the exception and still listens on0.0.0.0:9000: it relays every byte to a real aGate and never answers on its own behalf, so a client reaching it is talking to the gateway. Sitting on:9000between the app and the device is the point of that tool.
The emulator is a development aid. It serves what it was told to serve, so it is not evidence of how real hardware behaves.
Status: alpha. The protocol was reverse-engineered from packet captures. Frame parsing/encoding and the offline tooling are well tested; live transport against real hardware should be validated on your own LAN.
This is still work in progress - as some functions have not been fully tested and/or exposed yet.
For example (there may be others):
- set operating mode specific reserved state of change
- battery dispatch to force charge and discharge
- set battery or grid inverter power (in watts) for battery dispatch operations
- determining battery capabilities for the AC inverter (in watts) and battery capacity (in watt hours)
Why this exists
A FranklinWH aGate can be reached three different ways:
- The FranklinWH Cloud API — what the official mobile app and the FleetView installer portal use. Capable, but it routes through FranklinWH's servers and needs an account and an internet connection.
- Modbus TCP (SunSpec) — a standards-based local interface. Good for basic power/energy reads and a few setpoints, but only a narrow slice of what the device actually knows.
- The aGate's own local broker protocol — the proprietary
sendMqttcmdTypechannel on TCP/9000 that the app itself speaks under the hood. The official FranklinWH app calls this interface "Direct Connect." This is what this library implements.
The project exists to demonstrate that third path: a fully local, no-cloud, no-account way to query, control, and administer an aGate directly on your LAN — no FranklinWH servers, no Modbus gateway required. Because it's the device's native channel, it surfaces the deep structural telemetry the cloud strips out to keep the app fast (per-cell battery voltages, relay/contactor states, full physics arrays), plus configuration and control (operating mode, off-grid, reboot) — things neither a plain Modbus read nor the cloud expose together in one place.
⚖️ Disclaimer
UNOFFICIAL SOFTWARE — NOT AFFILIATED WITH OR ENDORSED BY FRANKLINWH.
This library speaks FranklinWH's undocumented Direct Connect (local) protocol on TCP/9000 — technically the same private channel the official FranklinWH mobile app uses, intended for that app and not for third-party use. It may change, break, or become unavailable without notice. It is provided AS-IS, without warranty of any kind, express or implied — use entirely at your own risk. The authors accept no liability for service interruptions, data loss, equipment damage, or any other consequences of using this software.
On the name "Direct Connect": the official FranklinWH app uses this label for the local interface; this project adopts the term purely to identify the same channel. It implies no affiliation with, endorsement by, or support from FranklinWH — this is unofficial, reverse-engineered software.
Do NOT contact FranklinWH support about this software. Raise issues, defects, or feature requests on GitHub instead: https://github.com/david2069/franklinwh-direct-connect-api/issues
Compliance & anti-circumvention
You agree to keep your gateway and battery settings, controls, and operation compliant with the configuration set through the official FranklinWH Mobile App and the installer/support FleetView portal.
FranklinWH-managed settings may exist to, among other things: protect the safety and longevity of the battery and gateway; apply automatic software updates and restrict your ability to view or change battery, grid-import, or grid-export controls; enforce your local grid profile and any import/export limits or prohibitions; and enforce restrictions tied to contractual incentives, subsidies, or VPP/grid programmes.
If you use this software to bypass or override any such control, restriction, or compliance measure — deliberately or inadvertently — you do so entirely at your own risk. This is neither condoned nor encouraged by the authors or any other party.
This software is provided for informational and educational purposes, AS-IS, with no warranty of fitness for any purpose. Any use — personal or commercial — is permitted under the MIT License and is entirely at your own risk.
As the MIT License requires, the copyright notice and this notice (including the Additional Terms) should be included in copies or substantial portions of the software — in forks, derivatives, and AI-assisted works alike, so the unofficial-app and compliance context travels with the code. See
LICENSE(Additional Terms) for the authoritative text.
Docs: https://david2069.github.io/franklinwh-direct-connect-api/ — Usage (full how-to) · Protocol & catalog (wire format + command catalog) · API reference. The same pages as markdown: docs/.
Setup
Requires Python 3.10+. No runtime dependencies (standard library only).
python3 -m venv .venv # 1. create a virtualenv
source .venv/bin/activate # 2. activate it (Windows: .venv\Scripts\activate)
pip install franklinwh-direct-connect-api
franklinwh-direct-connect --version # 3. verify
# franklinwh-direct-connect 0.4.0
To work on it instead, install the checkout editable — add [test] for the pytest suite:
git clone https://github.com/david2069/franklinwh-direct-connect-api
cd franklinwh-direct-connect-api
python3 -m venv .venv && source .venv/bin/activate
pip install -e ".[test]"
pytest -m "not live" # offline suite; "live" tests need a real aGate
How to run it
franklinwh-direct-connect is a console script that pip install puts on your
PATH — it is not a .py file in this repo, so these do not work:
python franklinwh-direct-connect ... # can't open file '.../franklinwh-direct-connect'
python franklinwh_direct_connect_api.py ... # no such file
Run it one of these three ways:
franklinwh-direct-connect catalog # venv activated (recommended)
.venv/bin/franklinwh-direct-connect catalog # venv not activated — call it by path
python -m franklinwh_direct_connect_api catalog # module form; works anywhere the package imports
One name throughout, as of 0.4.0: distribution franklinwh-direct-connect-api, import
package franklinwh_direct_connect_api, CLI franklinwh-direct-connect. Direct
Connect is FranklinWH's own term for this protocol.
Migrating from 0.3.x and earlier
The import package was franklinwh_local and the CLI was franklinwh-local. Both still
work and emit a DeprecationWarning; they are scheduled for removal in 0.6.0.
from franklinwh_local import LocalClient # 0.3.x — deprecated
from franklinwh_direct_connect_api import DirectConnectClient # 0.4.0 onward
The alias re-exports the same objects, so isinstance, subclassing and is comparisons
hold across both spellings — you can migrate file by file. LocalClient and
LocalTransport also remain as aliases of DirectConnectClient / DirectConnectTransport.
To find every remaining use, run with PYTHONWARNINGS=error::DeprecationWarning.
For a ready-made application built on this library — REST API, MQTT / Home Assistant entities and a web UI — see the FranklinWH Direct Connect Bridge.
Everything below assumes the venv is activated. Offline commands
(catalog, decode, analyze, emulate) need no hardware — start with
franklinwh-direct-connect catalog to confirm your install works.
Troubleshooting the install
| Symptom | Cause / fix |
|---|---|
can't open file '.../franklinwh-direct-connect' |
You ran python franklinwh-direct-connect. Drop the python — it's a command, not a script. |
command not found: franklinwh-direct-connect |
The venv isn't activated (source .venv/bin/activate), or pip install -e . hasn't been run in it. |
No module named franklinwh_direct_connect_api |
You're on a different interpreter than the one you installed into. Check with which python and pip -V — both should point inside .venv. |
DeprecationWarning: 'franklinwh_local' was renamed |
Expected whenever you import the old name (it still works). See Migrating; it stops working at 0.5.0. |
error: externally-managed-environment |
You ran pip install outside a venv on a Homebrew/system Python. Create and activate the venv first. |
Quick start
Decode a capture (offline, no hardware):
from franklinwh_direct_connect_api import iter_pcap_frames
for frame in iter_pcap_frames("capture.pcap"):
print(frame, frame.data_area)
Build and parse a single frame:
from franklinwh_direct_connect_api import encode_frame, decode_frame
wire = encode_frame(1301, "FAKEGATE90FJ09J6H4F2", {"opt": 0}) # power-flow poll
frame = decode_frame(wire)
assert frame.verify() # len + crc check
Talk to a live gateway:
from franklinwh_direct_connect_api import DirectConnectClient
with DirectConnectClient("10.100.1.1") as c: # the hotspot gateway IP
c.login() # 1101 -> 1102 (firmware manifest)
print(c.power_flow()["soc"])
print(c.smart_circuits())
bms = c.battery_cells(1) # per-cell telemetry, the deep read
print(bms["batVolt"]) # [3326, 3326, ...] mV per cell
print(bms["batTemp"]) # [18.8, 18.9, ...] degC per cell
print(bms["batSoh"]) # 94.9
Battery Management
franklinwh-direct-connect -i 192.0.2.110 battery # per-cell view
franklinwh-direct-connect -i 192.0.2.110 battery --watch 2 --for 10m
Per-cell voltages and temperatures, pack SoC/SoH, bus rails and states — one session,
local only. --watch/--for/--count monitor continuously; Ctrl-C stops.
Per-device reads
Four reads are addressed to a specific device rather than the gateway, and need an
id from device_check / battery_modules (devMap[].id):
franklinwh-direct-connect -i 192.0.2.110 battery_cells --id 1 # per-cell V + temps, SoC/SoH
franklinwh-direct-connect -i 192.0.2.110 power_electronics --id 1 # bus/grid/inverter V and A
franklinwh-direct-connect -i 192.0.2.110 device_firmware --id 1 # PE/BMS serials + versions
franklinwh-direct-connect -i 192.0.2.110 device_states --id 1 # DSP/main/PE/BMS states
Called without id they return the same keys with empty or zero values
(result=1 reason=-1) — easy to misread as "this command returns nothing".
Connecting (Direct Connection)
The aGate exposes TCP/9000 on its own WiFi hotspot — the same "Direct Connect" path the FranklinWH mobile app uses. To talk to it:
-
On the gateway/app, start Direct Connect → Connect via aGate hotspot.
-
Join the WiFi network
AP_<serial-suffix>(e.g.AP_F24170091). -
The gateway is the hotspot gateway IP (typically
10.100.1.1). PointDirectConnectClient/ the CLI at it, or let the scanner find it:franklinwh-direct-connect scan gateway # auto-targets the hotspot gateway franklinwh-direct-connect --host 10.100.1.1 power_flow
(The app also offers a Bluetooth Direct Connect path; only the WiFi/TCP path is implemented here.)
Discover devices on the LAN
franklinwh-direct-connect scan 10.100.1.0/24 # scan a subnet
franklinwh-direct-connect scan gateway # just the hotspot gateway
franklinwh-direct-connect scan 10.0.0.0/24 --json
Detects open TCP 9000 (sendMqtt) and TCP 502 (Modbus), and by default confirms a 9000 listener by performing the login handshake.
Test without hardware (emulator)
franklinwh-direct-connect emulate # fake aGate replaying captured data
# then, in another shell:
franklinwh-direct-connect --host 127.0.0.1 power_flow
CLI
franklinwh-direct-connect catalog # list known cmdType codes (grouped)
franklinwh-direct-connect catalog --grep bms # filter by name/description/cloud call
franklinwh-direct-connect catalog --json # ... as JSON, with cloud equivalents
franklinwh-direct-connect decode capture.pcap # decode a pcap
franklinwh-direct-connect decode capture.pcap --json # ... as JSON
franklinwh-direct-connect --host 10.100.1.1 power_flow # live read
franklinwh-direct-connect --host 10.100.1.1 call 1301 --data '{"opt":0}'
franklinwh-direct-connect --host 10.100.1.1 power_flow --watch 5 # poll every 5s
franklinwh-direct-connect --host 10.100.1.1 power_flow --watch 5 --count 12
Every name in catalog is a live subcommand — the command list is generated from
the catalog, so the two cannot drift. franklinwh-direct-connect -i <ip> grid_ov_trip works just
as power_flow does, and anything uncatalogued is still reachable via call <code>.
--watch [SECONDS] (default 5) reuses one logged-in session and prints a line
per poll — a friendly summary for power_flow, compact JSON otherwise.
--count N stops after N samples (Ctrl-C otherwise).
Control (live writes)
⚠️ These commands change a live energy system. Operating mode, off-grid/island state and reboot all take effect on real hardware immediately, and some are not visibly reversible from this library alone. Read Compliance & anti-circumvention before using them, and confirm every change in the official FranklinWH app afterwards — the app is the authoritative view of what your gateway is actually doing, and a write that this library reports as accepted is not proof the device applied it.
Confirmed working over LAN TCP/9000 (no SPAN unlock, no cloud) — see
catalog.WRITES and docs/PROTOCOL.md. The CLI
shape mirrors the sibling tools: -i/--ip for the aGate (as in
franklinwh-modbus), and a
get-or---set command (as in
franklinwh-cloud):
franklinwh-direct-connect -i 192.0.2.110 mode # just the current mode
franklinwh-direct-connect -i 192.0.2.110 mode --list # all modes + details
franklinwh-direct-connect -i 192.0.2.110 mode --json # decoded dataArea (JSON)
franklinwh-direct-connect -i 192.0.2.110 mode --raw # full on-the-wire frame (cmdType/snno/crc/...)
franklinwh-direct-connect -i 192.0.2.110 mode --set self # set; alias tou / self / sc / backup
franklinwh-direct-connect -i 192.0.2.110 mode --set 29287 # ...or a programme id
franklinwh-direct-connect -i 192.0.2.110 offgrid # show off-grid status
franklinwh-direct-connect -i 192.0.2.110 offgrid --set on --soc 5
franklinwh-direct-connect -i 192.0.2.110 offgrid --set off # reconnect
In Python:
from franklinwh_direct_connect_api import DirectConnectClient
with DirectConnectClient("192.0.2.110") as c:
c.login()
c.set_mode("tou") # 1727 {opt:3, current_id}; alias or full name or id
These command a real battery system.
mode --setreportscurrent_idbefore→after so you can confirm it took. Some settings (e.g. smart-circuit SoC cut-off) still round-trip through the cloud — use… call <cmd> --data '…'to experiment with codes not yet wrapped.
Finding new (write/control) commands
The catalog so far is reverse-engineered from read traffic. To discover the
write/control codes, capture the app while it issues a control action and
look for cmdTypes not yet in the catalog. You don't need Wireshark — macOS/Linux
ship tcpdump, and this library de-obfuscates the frames (Wireshark would only
show ciphered bytes):
# 1. capture phone <-> aGate :9000 (Direct-Connect hotspot or LAN), then in the
# app do ONE control action at a time (switch mode, start charge, toggle SC).
sudo tcpdump -i <iface> -s0 -w fwh.pcap 'tcp port 9000'
# 2. triage — lists every cmdType seen; flags the ones NOT in the catalog:
franklinwh-direct-connect analyze fwh.pcap
franklinwh-direct-connect analyze fwh.pcap --unknown # just the candidate write codes
Or watch the conversation live with a transparent decoding proxy — redirect
the app's :9000 to it (ARP-spoof + DNAT, or a host route); it forwards every
byte verbatim and prints each decoded frame, flagging unknown cmdTypes:
franklinwh-direct-connect proxy 192.0.2.110 # relay :9000 -> aGate:9000
franklinwh-direct-connect proxy 192.0.2.110 --listen 0.0.0.0:9000
franklinwh-direct-connect proxy 192.0.2.110 --record session.pcap # capture on demand
# session.pcap opens in Wireshark and re-decodes: franklinwh-direct-connect decode session.pcap
Unknown odd codes captured during a control action are the requests; their
dataAreacarries the setpoint. Add confirmed codes tocatalog.py.
Or sweep the gateway directly with probe, which tries several request payload
shapes per code rather than only the usual {"opt":0}:
franklinwh-direct-connect -i 192.0.2.110 probe # all uncatalogued odd codes
franklinwh-direct-connect -i 192.0.2.110 probe --range 1413-1699 # one block
franklinwh-direct-connect -i 192.0.2.110 probe --json > probe.json
Some reads are addressed per battery, not per gateway — the cloud API's per-cell BMS
read sends {"fhpSn": "<aPower serial>", "type": 2|3}. A code like that answers a plain
{"opt":0} probe with silence, so a single-shape sweep cannot find it. probe
auto-discovers the battery serials (from battery_modules + the login manifest), tries
each shape, reports which one produced data, and flags replies that look like per-cell
telemetry. It only ever sends reads — never opt=1.
Caution: this sends cmdTypes whose semantics are unknown to a real battery system. The payload matrix is read-shaped by construction, but scope your sweeps (
--codes,--range) rather than blanket-probing a production gateway.
How the protocol works
A frame is one JSON object. The header is cleartext; everything from "type"
onward is obfuscated with a trivial position-based additive cipher:
{"cmdType":<N>,"equipNo":"<E>", <- cleartext header
"type":...,"timeStamp":...,"snno":...,"len":<L>,"crc":"<C>","dataArea":{...}}
\------------------------ ciphered region (i = 0 here) ----------------------/
encrypt: c[i] = (p[i] + seed + i) & 0xFF
decrypt: p[i] = (c[i] - seed - i) & 0xFF
There is no key, and the seed is derived from the serial in the equipNo
header — (sum(utf8(equipNo)) + len(equipNo) + 29) mod 256. That yields 0xA5 for the
pre-login 1101 handshake ("00000000") and 0x3F for the reference gateway's 20-char
serial; another serial gives another seed, so it must be derived, not hardcoded. Because
the first plaintext byte is always ", decoding is self-synchronizing — the seed is
recovered from the first ciphered byte, so any frame can be read without knowing the
serial. (The formula is voidstarr/franklinwh_local's finding; see
docs/PROTOCOL.md.)
Field rules: len is the byte length of the compact dataArea JSON, and crc
is its CRC32 (uppercase hex). Full details and the command catalog are in
docs/PROTOCOL.md.
Security note
The broker channel is plain TCP and the obfuscation is keyless, so anyone on the LAN path can read and forge frames. Decoded payloads expose WiFi credentials, device serials, firmware versions, and GPS/location. Treat the network segment accordingly.
Before you attach anything to an issue. Packet captures, .pcap files and the output of
--raw, proxy and probe contain those same values in clear — WiFi credentials, serial
numbers, firmware versions and your location. Redact them first: replace serials and
MACs with placeholders, and use the documentation address ranges (192.0.2.x) rather than
your own. A capture posted to a public issue is a capture published.
Layout
franklinwh_direct_connect_api/
protocol.py cipher, Frame, encode/decode, FrameStream, pcap reader
catalog.py cmdType catalog + enums (RUN_STATUS, WRITES, OPERATING_MODES)
transport.py TCP client: connect, login, request/response (serialised)
client.py high-level named commands (reads + the six writes)
cli.py command-line entry point
discover.py LAN scan for :9000 / :502
emulator.py fake aGate broker, backed by synthetic.py
synthetic.py deterministic per-seed synthetic site
energy.py 1303/1407 helpers: rollups, TOU blocks, tariff tiers
bms.py per-cell battery rendering for the `battery` command
probe.py read-only cmdType sweep with a payload matrix
proxy.py transparent decoding relay
franklinwh_local/ deprecated import shim (to be removed in 0.6.0)
tests/ pytest suite (emulator- and capture-driven)
docs/ the published guide (mkdocs): USAGE, PROTOCOL, API, CLOUD_MAPPING
License
MIT, plus Additional Terms — unofficial and not affiliated with or endorsed by
FranklinWH, with a compliance and anti-circumvention clause. See LICENSE for the
authoritative text and Disclaimer for the readable version.
Metadata
Release files for franklinwh-direct-connect-api 0.6.0
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| franklinwh_direct_connect_api-0.6.0.tar.gz | 174.9 kB | With provenance | Details for franklinwh_direct_connect_api-0.6.0.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| franklinwh_direct_connect_api-0.6.0-py3-none-any.whl | Python 3 | none | any | Details for franklinwh_direct_connect_api-0.6.0-py3-none-any.whl |
Total release size: 304.5 kB
Release files / franklinwh_direct_connect_api-0.6.0.tar.gz
| Download URL | franklinwh_direct_connect_api-0.6.0.tar.gz |
|---|---|
| Size | 174.9 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
80a0ae9b7b5833ec21c329444741bf6c49f5ff30bd284a08a3ab693f7f46d9cc
|
|
BLAKE2b-256 checksum How to use checksums |
2b52ad72d2c64ab6184527018d6d0f16cdb4a4c7b5bdd8dc62a7f3c7ef3d7cbb
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 3, 2026.
Transparency logRelease files / franklinwh_direct_connect_api-0.6.0-py3-none-any.whl
| Download URL | franklinwh_direct_connect_api-0.6.0-py3-none-any.whl |
|---|---|
| Size | 129.6 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
ba4b1b98f05ffcc63328dba7259207bf28255571fe5dfc5284b73b683acf8414
|
|
BLAKE2b-256 checksum How to use checksums |
5b7f5daa3a0a87fbde69c7e21bfb57fc2ba9b972b558f8225608207effd3e586
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 3, 2026.
Transparency logSecurity for franklinwh-direct-connect-api 0.6.0
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
Full provenance
Both files in this release have been uploaded with provenance metadata.
Attestation for franklinwh_direct_connect_api-0.6.0.tar.gz
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 3, 2026.
Transparency logA note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.