Nilan Connect
An event-driven Python client for Nilan and Genvex ventilation units behind their gateway, over the gateway's local micro_nabto protocol, built on modbus_event_connect.
You subscribe to the values you care about and are told when one changes - with its quality, so "offline", "no reading" and a real value never look alike.
Supported controllers
| Controller | Status |
|---|---|
| Nilan CTS400 | Tested: every point checked against Nilan's Modbus manual and read from a unit |
| Genvex Optima 270 | Tested: read from a unit |
| Nilan CTS602, every variant including Geo | Untested, apart from four temperatures (T2, T3, T4, T8) read from a unit |
| Nilan CTS602 Light | Untested |
| Genvex Optima 250, 251, 260, 301, 312, 314 | Untested |
The gateway's addresses of the untested controllers are derived and calculated from the
material we could find online, and have not been tested on those controllers. Values may be
wrong or missing; reports of what a unit shows are welcome. connect() raises
UnsupportedDeviceError for any other controller.
A point's certainty says how certain it is that the point is right:
Certainty |
Meaning |
|---|---|
VERIFIED |
Read on a unit of the model. |
REPORTED |
Found in material published online; not read on a unit of the model. |
INFERRED |
Placed from the model's Modbus manual by the order of its register group; not read on a unit of the model, and not found elsewhere. |
On a CTS602 the gateway does not use the manual's addresses. Within one of the manual's register
groups - blocks of 100, such as the temperatures from input register 200 - it keeps the manual's
order and spacing, so a group's other registers follow from one known address in it: those are
the inferred points. A setting among them can be written, as a test of it needs to; whether a
user is offered that is the consumer's choice. A consumer that wants only what has been seen
working leaves the inferred points out:
from nilan_connect import Certainty
shown = [point for point in client.points.values() if point.certainty is not Certainty.INFERRED]
Installation
pip install nilan-connect
Everything you use comes from nilan_connect: the client and its values, the errors, discovery,
and, in nilan_connect.testing, a simulated gateway and a client of it for your own tests.
modbus_event_connect is installed with it; nothing needs importing from it. The client is the
DeviceClient every device library built on event_connect shares, and the names they share
(Status, Quality, PollRate, the errors, ...) are event_connect's own.
Usage
import asyncio
from nilan_connect import PointKey, create_client
def on_change(key, old, new):
print(f"{key}: {new.value} ({new.quality.name})")
async def main():
# The email is the account the gateway is paired with in Nilan's app.
client = create_client(email="you@example.com", host="192.0.2.10")
await client.connect() # reads the handshake and chooses the controller's model
client.subscribe(PointKey.TEMP_OUTSIDE, on_change)
client.subscribe(PointKey.FILTER_OK, on_change)
await client.run() # reads whatever is due, until cancelled
asyncio.run(main())
create_client takes keyword arguments only: email, host, device_id, port (micro_nabto's
standard PORT unless given), read_only and clock. With only a device_id, the gateway is
found by discovery, and with both, a gateway that has moved is found again. run() is the whole
poll loop, and never ends by itself: it waits while the client is not connected, and logs a poll
that raises and polls on after a pause. A program with a loop of its own calls poll(), which
reads only what is due, and waits seconds_until_next_poll().
from nilan_connect import discover
async def find():
for gateway in await discover(): # every gateway on the local network
print(gateway.host, gateway.port, gateway.device_id)
return await discover(target="192.0.2.10") # the gateway at one address
Discovery waits two seconds for answers.
How often values are read
Each controller's model says when its points are read, and nothing outside the model or
create_client changes it. Every model reads the controller's readings every 10 seconds, its
settings every 180 seconds, and a setting again one second after it is written. What a write
changes is read again too: after a filter reset on a CTS400, the filter's status and timers and
the alarm status, two seconds later; after a filter interval, the days left, two seconds later;
after a fan level, on every controller, the levels the fans run at and their speeds, three
seconds later. The setting itself is read back after one second either way. A CTS400 is checked
every 900 seconds for whether a CO2 or VOC sensor has been fitted or taken out.
Only what is subscribed to, or asked for with refresh(), is read.
The gateway
The gateway is a device of its own between the network and the controller. It reaches the controller over RS-485 Modbus at 19,200 baud, as the master, and gives the controller's registers addresses of its own.
It answers from what it holds, not from the controller. A CTS602's gateway answered reads of 4 to 31 registers within 7 to 24 ms, the trip over the network included. Asked of the controller over RS-485, one register alone takes about 13 ms, and those reads, which span up to five of the manual's register groups, at least 40 to 95 ms.
What is known of a gateway was seen on the gateway of one controller or another, and is named with it here; whether the others' gateways behave alike is not known. Each controller's model states how its gateway is talked to: where nothing was seen on that controller's gateway, with what was seen on another's, or a guess.
A gateway counts as not answering once it has left reads unanswered for 10 seconds: one missed read keeps the last values, and a gateway that stays silent shows as not answering. After a failed handshake it is asked again after 5 seconds, before the next read is due. A read the gateway has said it has is given 2 seconds to be answered, a write or a first handshake 5 seconds: a CTS602's gateway answered 21,000 reads within 245 ms.
What it holds can be empty. A CTS602's gateway answered the first reads of a new session with only zeros, at once and again 18 ms later, and with values 10 s later. The same gateway was reported leaving a read unanswered every 33 minutes and answering the next. Not known yet:
- whether it empties what it holds when a session begins, when it restarts, or at some interval;
- how long it takes to fill it;
- whether every controller's gateway works this way: only a CTS602's has been measured.
modbus_event_connect handles such an answer for any device, also one read directly: the last values are kept while the registers are read again, and the zeros are taken if they stay. It logs, as warnings, why each session began, when the gateway went silent and answered again, and how long it took to answer values. Those lines answer the questions above; please include them in a report.
Writing
await client.write(PointKey.TEMP_TARGET, 21.5)
await client.write(PointKey.FILTER_REPLACE_RESET, True) # an action: nothing to read back
A value outside the limits Nilan's manual gives is refused before anything is sent.
create_client(..., read_only=True) refuses every write.
A CTS400's gateway answered some writes with a status saying it did not take them, and took the same write on a later try. Such a write is sent again every half second, for up to 15 seconds after it was first sent; every model does so, as nothing else is known. A newer value for the same setting takes over from it.
How each controller is talked to
Each model is a MicroNabtoModel in a file of its own, read top to bottom: its points, when they
are read, and how its gateway is talked to, each number with where it comes from. MODELS lists
them all, and select_model chooses one from the gateway's handshake. Every model asks its
gateway for at most 64 registers in one read. A read sent again, as its receipt did not come, and
answered with only zeros where the registers held values, is kept open for a later answer: 1 s
for a CTS400, the 1 s a request is given before it is sent again, and 5 s for the other
controllers, on which it has not been measured. Until the controller's model is known, the
longest of them is used.
Keys
A key is the stable name of a point, and carries the type of its value. A key string never changes, so what a consumer builds on it keeps working.
Every key is in PointKey. Which keys a controller has, and at which registers, is its model's:
client.points lists the points of the unit connected, each with its unit, limits and whether
it is read, written or both.
filter_ok is the CTS400 manual's "filter change status" the other way round, and
humidity_high_active is whether its "time of high humidity" counts. Its "average level
humidity 24 hours OK" is humidity_average_ok.
Controllers share a key wherever a value means the same.
States
A value with named states is an IntEnum, one for all controllers: Alarm, OperationState,
OperationMode, Weekday, HeatSource, CompressorPriority, CoolingSetpoint,
AirExchangeMode, ControlSensor, CentralHeatMode, CirculationPumpMode, ServiceMode,
DamperTestState, FilterReplaceInterval and ExtraSensor. Each controller maps its own numbers onto them, so a state means the same
whichever controller reports it: a CTS400's alarm 1 and a CTS602's alarm 19 are both
Alarm.CHANGE_FILTER.
- A key ending in
_codeholds the controller's own number. What it means is a key of its own:alarm_1foralarm_1_code,operation_stateforstate_code. - An Optima reports its alarms as bits. Each is a
boolkey named after its alarm, such asalarm_external_stop; its filter alarm isfilter_ok, the other way round. - A sensor alarm names the sensor by the controller's T number, as the controller's panel does.
- When an alarm was raised (
alarm_1_time) and when the damper last tested itself (damper_test_last_date) are in the controller's own clock, without a time zone.
Documentation
docs/models holds the manufacturers' manuals for every controller, with every register extracted to CSV.
A note to Nilan
Thank you for publishing the Modbus descriptions of your controllers, and for gateways that answer on their owner's own network. They are what lets an owner fit a Nilan unit into a home the way they want it.
We know a gateway can be updated remotely, and that its local access could be closed. Please keep it open. A local connection needs the email the gateway is paired with in your app, and it reaches the same values your Modbus descriptions give anyone who wires to the controller directly: it adds nothing Modbus does not already allow, and it makes your gateway worth more to the people who own one.
Disclaimer
Not affiliated with Nilan or Genvex. Use at your own risk; no warranty.
License
MIT. See LICENSE.
Metadata
Release files for nilan-connect 0.7.0
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| nilan_connect-0.7.0.tar.gz | 11.7 MB | With provenance | Details for nilan_connect-0.7.0.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| nilan_connect-0.7.0-py3-none-any.whl | Python 3 | none | any | Details for nilan_connect-0.7.0-py3-none-any.whl |
Total release size: 11.7 MB
Release files / nilan_connect-0.7.0.tar.gz
| Download URL | nilan_connect-0.7.0.tar.gz |
|---|---|
| Size | 11.7 MB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
b4ac2502a796568b470c94bc4421d350e84ba1749e9c33a4f9cdddaffb2a9002
|
|
BLAKE2b-256 checksum How to use checksums |
b109f9c1d3efc09a81ded98782eef3d8124e07001a6178fd85db71aff01d8752
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 18, 2026.
Transparency logRelease files / nilan_connect-0.7.0-py3-none-any.whl
| Download URL | nilan_connect-0.7.0-py3-none-any.whl |
|---|---|
| Size | 44.0 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
40be8a7b71221c9f6ac682cf4498093484c6ee190f9237e4ab17677d21dca9a8
|
|
BLAKE2b-256 checksum How to use checksums |
85617c5df8a47a373899e1a6370a27cb7b66ce67f01acbd7050435276a2f82d5
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 18, 2026.
Transparency logSecurity for nilan-connect 0.7.0
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
Full provenance
Both files in this release have been uploaded with provenance metadata.
Attestation for nilan_connect-0.7.0.tar.gz
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 18, 2026.
Transparency logA note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.